Installation instructions
Compact speed monitor
DIA
701092 / 03 09 / 2007
UK
UK
UK
UK
UK
2
1 Functions and features
The Compact speed monitor detects without contact whether a minimum speed is
reached and signals underspeed by means of a switching signal.
Nominal sensing range (Sn) 10 mm; Preset speed adjustable, see type label.
2 Installation
E
A
BC
D
F
A
B
C
³F
³2 x A
½ x Sn
D
E
Fix the unit by means of a mounting device and secure it by means of the nuts
provided so that it cannot work loose. Flush installation.
Adhere to the above dimensions to ensure a correct function.
3 Electrical connection
Disconnect power.
Connect the unit according to the indications on the type label.
Note: insert a miniature fuse according to the technical data sheet, if specified.
Recommendation: check the safe functioning of the unit after a short circuit.
3
UK
4 Adjustment
1
2
LEDs
Green LED: output switched (actual
speed > preset speed)
Yellow LED (optional for 2-wire AC/DC):
sensor damped
multiturn potentiometer
preset value
1.
2.
Keep the speed to be monitored in the plant on a constant level.
The yellow LED must flash (damping pulses are detected).
Start the adjustment according to A or B when the start-up delay* (AÜ see type
label) has elapsed.
A
Green LED lit
B
Green LED not lit
Turn the pot clockwise until the LED goes
off.
Turn the pot slowly anticlockwise until the
LED is lit.
Turn the pot slowly anticlockwise until the
LED is let.
On delivery: pot at the right end stop (except DI5011 = approx. 30 pulses/min).
5 Operation
The operation is maintenance-free. Ensure the following for a correct function:
Keep the sensing face and the open space free of metal deposits and foreign
bodies.
Do not operate units with high field intensity (e.g. walkie-talkies) at close range
to the speed monitor.
*) The start-up delay (AÜ) suppresses an error signal as long as the machine is in
the process of starting and has not yet reached its nominal speed. After applica-
tion of the operating voltage the start-up delay is active only once.
If the drive is often turned on and off, couple the supply voltage of the drive and
the monitor. By doing so, the start-up delay is active every time the drive is turned
on.


Specyfikacje produktu

Marka: IFM
Kategoria: Niesklasyfikowane
Model: DI5011

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z IFM DI5011, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane IFM

IFM

IFM TW2001 Instrukcja

14 Stycznia 2025
IFM

IFM EVC231 Instrukcja

13 Stycznia 2025
IFM

IFM UGT582 Instrukcja

13 Stycznia 2025
IFM

IFM TY0058 Instrukcja

13 Stycznia 2025
IFM

IFM OT5012 Instrukcja

11 Stycznia 2025
IFM

IFM SUH201 Instrukcja

11 Stycznia 2025
IFM

IFM LW2760 Instrukcja

5 Stycznia 2025
IFM

IFM AL2305 Instrukcja

5 Stycznia 2025
IFM

IFM E30560 Instrukcja

5 Stycznia 2025
IFM

IFM E30559 Instrukcja

5 Stycznia 2025

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane