Instrukcja obsługi Ibm System x x3755 M3
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Ibm System x x3755 M3 (17 stron) w kategorii serwer. Ta instrukcja była pomocna dla 10 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/17
Superior performance/U in a 4-socket, 2U server with up to 64 processor cores
Please see the Legal Information section for important notices and information. 1
Product Guide
November 2011
IBM System x3755 M3
Product Overview
CONTENTS
Product Overview
1
Selling Features
1
Key Features
3
Key Options
9
x3755 M3 Images
10
x3755 M3 Specifications 1
1
The Bottom Line 1
4
Server Comparison Chart
1
6
For More Information 1
7
Legal Information 1
7
Outstanding price/performance for mid-size workloads
Suggested Uses: Businesses requiring a rack-optimized compute-dense server for business
intelligence, midsized databases or virtualization, ERP, HPC, and the like.
The challenge today is to squeeze as much performance out of your IT dollars as possible, while
saving cost on features not needed. The IBMfour-socket, ® , incorporating System x3755 M3
IBM X-Architecture™ features, meets that challenge. It was designed to eliminate system
architecture bottlenecks through the use of separate, high-speed links between the processors,
main memory and I/O. It is well suited for application workloads that benefit from a 4-processor
system with outstanding price/performance, offering high compute density, large memory
capacity, and high I/O throughput, all in a small rack footprint. Up to x3755 M3 servers can be 21
installed in a single 42U rack, offering the compute density of up to processors ( cores) 84 1344
per rack.
The x3755 M3 supports the latest , and AMD and series 16- 12- 8-core Opteron 6200 6100
processors with DirectConnect Architecture and HyperTransport technology, to offer impressive
computing power in a rack-optimized design. This server offers up to processor cores, 2U 64
high memory bandwidth high floating-point performance, and at an affordable price. The
x3755 M3 offers up to 512GB1 of industry-standard ( ) memory with DDR3 PC3-10600 Chipkill™
ECC (Error Checking and Correcting) protection—for high performance and reliability. For even
higher levels of availability, the x3755 M3 also offers . online memory sparing Two dual-port
integrated controllers are standard—offering (TCP offload engine), , Gigabit Ethernet TOE iSCSI
and support, and capabilities, along with high-performance RDMA load-balancing failover four
PCIe Gen 2 adapter slots.
All models offer support for either or and a choice of high-performance two four processors
hard disk drives with an internal storage capacity of up to 24TB
2 (eight 3.5-inch hot-swap SAS
or HDDs). Alternatively, up to ( drives) is supported SATA 18TB six 3.5-inch simple-swap SATA
via the configure-to-order (CTO) process. The integrated ServeRAID
™ SAS (Serial Attach
SCSI)/ (Serial-attach ATA) controller provides hardware-based orSATA RAID-0/1/10 RAID-
0/1/10/5/50 support standard (model-specific). Additional RAID support is available via upgrade.
Standard in the x3755 M3 is an integrated Baseboard Management Controller (iBMC) that
enables the user to manage and control the server easily—both locally and remotely. This high
level of manageability is designed to keep costs down and the system up. A pop-out/drop-down
light path diagnostics panel enables quick servicing of the system if a problem develops.
These advanced features help maximize network availability by increasing uptime, as do
integrated ; ; support, includingRAID temperature-controlled fans IPMI 2.0 highly secure
remote power control Serial over LAN text-console redirect over LAN and ; as well as .
Another improvement in the new generation of X-Architecture is the replacement of legacy BIOS
with a new generation (UEFI). UEFI provides a more Unified Extensible Firmware Interface
intuitive user interface and understandable event logs and better management.
With the inclusion of unique IBM service and support features such as IBM Active Memory
™, the
iBMC, UEFI, light path diagnostics, ,IBM Systems Director IBM ServerGuide
™, and others, the
x3755 M3 is designed for maximum uptime.
If you need highly manageable, quad-socket/multi-core price/performer in a rack-dense 2U
package, the x3755 M3 is the ideal system.
Selling Features
Price/Performance
The x3755 M3 offers numerous features to boost performance and reduce product and operating
costs:
1 Maximum memory and disk capacity may require the replacement of standard components with the largest supported component
available. capacity using DIMMs requires a system in order to use all sockets. In a two-processor 512GB 16GB 4-processor 64
configuration, only total DIMM sockets are available; thus a two-processor system is limited to of RAM (16 x 16GB).16 256GB
2 GB equals 1,000,000,000 bytes when referring to hard disk drive capacity. Accessible capacity may be less.
®
Superior performance/U in a 4-socket, 2U server with up to 64 processor cores
Please see the Legal Information section for important notices and information. 2
• Up to , or Opteron 6000 series processors with HyperTransport four 16- 12- 8-core
Technology, DirectConnect Architecture and of integrated Level 3 cache per processor 12MB
offer solid performance capable of tackling the toughest jobs.
• Each processor includes (one per memory channel), for up 4 integrated memory controllers
to . 16 memory controllers per server
• use less power and produce lest waste heat than less efficient Energy-efficient processors
processors, thus helping to reduce data center energy costs. For example, the 12-core 115W
(maximum) processors only 80W in typical use, which is under 7W per core. average
• All x3755 M3 servers support 2 DIMMs per channel ( ) at 1333MHz. 2DPC
• Fast ECC memory with error correction and PC3-10600 DDR3 Chipkill online memory
sparing protection provides speed and high availability.
• high-speed adapter slots offer investment protection by supporting high-Four PCIe Gen 2
performance adapters, such as 10Gb Ethernet and InfiniBand
™ cards.
• Integrated controllers support or standard (model-ServeRAID RAID-0/1/10 RAID-0/1/10/5/50
specific), upgradeable to . RAID-0/1/10/5/50
• Up to of 3.5-inch or storage offers high-performance with high 24TB hot-swap SAS SATA
availability, while up to of (via CTO) storage offers low-cost with 18TB simple-swap SATA
higher availability than fixed HDDs.
• integrated controllers with support provide 4 ports Two dual-port Gigabit Ethernet IPMI 2.0
for high-speed network communications.
• Support for TCP Offload Engine ( ), , and offers higher performance for TOE iSCSI RDMA
TCP/IP traffic, with less overhead on the system processor.
• A —including quad Gigabit Ethernet, systems high degree of device integration
management and video controllers—lowers costs and frees up valuable adapter slots.
Flexibility
The x3755 M3 has the ability to grow with your application requirements, thanks to:
• A choice of Opteron processors with through clock rates and - maximum1.7 3.0GHz 79 140W
power draw ( average). 65-105W
• Up to of high-speed DDR3 system memory ( ). 512GB 128GB per processor
• Up to or HDDs (up to or ), or up to (via eight hot-swap SAS SATA 24TB SAS SATA six
CTO) HDDs (up to ). simple-swap SATA 18TB
• adapter slots ( in all Three available high-performance one PCIe x16, one x8, one x4
models (plus slot containing the ServeRAID controller).one x8
• support for Hardware-based RAID-0/1/10 RAID-5/50 (upgradeable to ) is provided standard in
most models. Other models provide standard (upgradeable with RAID-0/1/10/5/50 RAID-6/60
and battery backup).
• The ports are up to fasterfive USB 2.0 40X 3 than older ports. This provides speedy USB 1.1
access to external HDDs (non-arrayed), optical drives, tape drives, and other USB devices.
Two ports are on the front of the unit, one is internal, and two are on the back.
Manageability
Powerful systems management features simplify local and remote management of the x3755 M3:
• The x3755 M3 includes an integrated to monitor Baseboard Management Controller (iBMC)
server availability, perform Predictive Failure Analysis, etc., and trigger IBM Systems Director
alerts. The BMC enables service personnel to use sophisticated diagnostic tools, such as light
path diagnostics and , to resolve problems quickly. The remote presence Serial over LAN
feature offers remote control of keyboard, video, and mouse, graphical console redirection
over LAN, remote virtual floppy and CD-ROM, plus the latest OS failure screen capture.
• Integrated support alerts IBM Systems Director to anomalous environmental factors, IPMI 2.0
such as voltage and thermal conditions. It also supports highly secure remote power
control using data encryption.
• support allows the administrator to remotely view x3755 M3 text Text Console Redirection
messages over Serial or LAN.
• Integrated industry-standard Unified Extensible Firmware Interface ( ) next-generation UEFI
BIOS. New capabilities include:
– Human readable event logs — no more beep codes
3 Data transfer rates may be less than the maximum possible.
Superior performance/U in a 4-socket, 2U server with up to 64 processor cores
Please see the Legal Information section for important notices and information. 3
– Complete out-of-band coverage by the Advance Settings Utility to simplify remote setup
– A complete setup solution, allowing adapter configuration functions to be moved into UEFI
– Consistent firmware management across an entire product line
• Integrated support. Trusted Platform Module (TPM) 1.2
• IBM Systems Director is provided for proactive systems management. It comes with a portfolio
of tools. In addition, IBM Systems Director offers extended systems management tools for
additional server management and increased availability.
Availability and Serviceability
The x3755 M3 provides many features to simplify serviceability and increase system uptime:
• x3755 M3 servers support memory DIMMs. Chipkill memory is up to Chipkill-enabled 16X
better than standard ECC memory at correcting memory errors. This can help reduce
downtime caused by memory errors.
• The x3755 M3 offers for redundancy in the event of a noncorrectable online memory sparing
memory failure.
• provides easy access to upgrades and serviceable parts. Similarly, Toolless cover removal
the , , , and can be installed and replaced without DIMMS HDDs system battery adapters
tools. This means less time (and therefore less money) spent servicing the x3755 M3.
Additionally, and (optional via CTO) hot-swap/redundant HDDs, fan modules power
supplies mean greater system uptime while these components are being serviced.
• New ship with the server, together with a , toolless slides Cable Management Arm (CMA)
that allow the rack server to easily slide into place
• IBM allows the administrator to evaluate thermal data on the server Thermal Diagnostics
without taking the hardware offline. This can provide greater server uptime.
• The and individual light path LEDs quickly lead the drop-down light path diagnostics panel
technician to failed (or failing) components. This simplifies servicing, speeds up problem
resolution and helps improve network availability.
• The RAID controller enhances system availability and data. integrated 6Gbps
• IPMI 2.0 supports highly secure remote system power control using data encryption. This
allows an administrator to restart a server without having to visit it in person, saving travel time
and getting the server back up and running quickly and securely. It also adds new features to
those provided by IPMI 1.5, including support, , enhanced VLAN Serial over LAN
authentication and encryption algorithms ( and ) and a . RMCP+ AES firmware firewall
• adjust to compensate for changing Temperature-controlled hot-swap redundant fans
thermal characteristics. At the lower speeds they draw less power and suffer less wear.
Equally important in a crowded data center, temperature-controlled fans produce less ambient
noise in the data center than if they were constantly running at full speed. (Nonredundant
simple-swap fans are available via CTO.)
• Standard or optional (model-specific) providing or hot-swap/redundant power supplies N+N
N+1 redundancy (up to three PSes).
• The three-year (parts and labor) limited onsite warranty
4 helps afford you peace of mind
and greater investment protection than a one-year warranty does.
Key Features
High
-
Performance
Multi
-
Core Opteron
Processors
The x3755 M3 supports up to four high-performance 16-, 12-, or 8-core AMD Opteron 6200 or
12-, or 8-core Opteron 6100 series processors in only 2U of rack space. The x3755 M3 offers a
choice of processors:
Opteron 6200
• maximum (105W average) Opteron operating at 2.6Ghz with 140W 16-core 6282SE very low
power draw per core ( ), GTps (gigatransfers per second), memory 8.75W 6.4 1333MHz
access, quad integrated memory controllers, and of processor cache ( per core) 16MB L3 1MB
• maximum (80W average) Opteron , , or operating at 2.3, 2.2, 115W 16-core 6276 6274* 6272
or 2.1GHz (respectively) with ( ), GTps (gigatransfers very low power draw per core 7.2W 6.4
per second), memory access, quad integrated memory controllers, and of 1333MHz 16MB L3
processor cache ( per core) 1MB
4 For terms and conditions or copies of the IBM Statement of Limited Warranty, call 800-772-2227 in the U.S. In Canada call 800-
426-2255. Telephone support may be subject to additional charges. For warranties including onsite labor, a technician is sent after
IBM attempts to resolve the problem remotely. International warranty service is available in any country in which this product is
sold.
Specyfikacje produktu
Marka: | Ibm |
Kategoria: | serwer |
Model: | System x x3755 M3 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Ibm System x x3755 M3, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje serwer Ibm
22 Września 2024
20 Września 2024
20 Września 2024
16 Września 2024
16 Września 2024
15 Września 2024
15 Września 2024
15 Września 2024
15 Września 2024
15 Września 2024
Instrukcje serwer
- serwer Sony
- serwer Supermicro
- serwer Lenovo
- serwer Gigabyte
- serwer Acer
- serwer Technics
- serwer Hikvision
- serwer Fujitsu
- serwer Conceptronic
- serwer StarTech.com
- serwer Asus
- serwer D-Link
- serwer ATen
- serwer APC
- serwer HP
- serwer Tripp Lite
- serwer Cisco
- serwer Moxa
- serwer Synology
- serwer Lindy
- serwer ZyXEL
- serwer Dell
- serwer Linksys
- serwer Digitus
- serwer Vimar
- serwer Netgear
- serwer Black Box
- serwer Intellinet
- serwer HGST
- serwer Revox
- serwer Naim
- serwer SEH
- serwer Planet
- serwer NEC
- serwer Digi
- serwer Axis
- serwer Abus
- serwer Rocstor
- serwer Western Digital
- serwer Smart-AVI
- serwer Promise Technology
- serwer QNAP
- serwer Chenbro Micom
- serwer Allnet
- serwer Veritas
- serwer IStarUSA
- serwer Silverstone
- serwer Ernitec
- serwer AVerMedia
- serwer Atlona
- serwer Gefen
- serwer Hanwha
- serwer Quantum
- serwer Eaton
- serwer Monacor
- serwer Sonnet
- serwer In Win
- serwer Teo
- serwer Megasat
- serwer Areca
- serwer AMX
- serwer C2G
- serwer Maxdata
- serwer Matrox
- serwer Flir
- serwer Buffalo
- serwer GeoVision
- serwer LaCie
- serwer Valcom
- serwer Asustor
- serwer Intel
- serwer Fantec
- serwer Freecom
- serwer Seagate
- serwer Iomega
- serwer Provision ISR
- serwer TAIDEN
- serwer SIIG
- serwer Advantech
- serwer Extron
- serwer Avocent
- serwer Silex
- serwer Sun
- serwer MvixUSA
- serwer Dual Bay
- serwer Raidsonic
- serwer EMC
- serwer Infortrend
- serwer Opengear
- serwer G-Technology
- serwer EXSYS
- serwer Mr. Signal
- serwer Atlantis Land
- serwer Lantronix
- serwer NETSCOUT
- serwer Mobotix
- serwer Origin Storage
Najnowsze instrukcje dla serwer
9 Grudnia 2024
9 Grudnia 2024
8 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
13 Października 2024
12 Października 2024
12 Października 2024
11 Października 2024