Package Includes:
Lyric T6 PRO WiFi Thermostat
UWP Mounting System
Honeywell Standard Installation
Adapter (J-box adapter)
Honeywell Decorative Cover Plate
Small; size 449/64 in = 121mm.
Screws and anchors
Professional Install Guide
Getting Started Guide
*TH6320WF2003 depicted. Other models may vary.
Lyric™ T6 Pro Wi-Fi
Programmable Thermostat
Professional Install
Guide
33-00153-0
7
Compatibility
Compatible with most heating, cooling, and heat pump systems
Required: 24 VAC power (“C” wire)
Does not work with electric baseboard heat (120240V)
Does not work with millivolt systems
Android or iOS smartphone or tablet
Customer assistance
WEB customer.honeywell.com
PHONE 18006333991
2
UWP Mounting System installation
1. Open package to find the UWP. See
Figure 1.
2. Position the UWP on the wall. Level and
mark hole positions. See Figure 2.
Drill holes at marked positions, and
then lightly tap supplied wall anchors
into wall using a hammer.
Drill 7/32” holes for drywall.
3. Pull the door open and insert wires
through wiring hole of the UWP. See
Figure 3.
4. Place the UWP over the wall anchors.
Insert and tighten mounting screws
supplied with the UWP. Do not
overtighten. Tighten until the UWP
no longer moves. Close the door. See
Figure 4.
1
3
Optional Decorative Cover Plate installation
Use the Optional Cover Plate when:
Mounting the thermostat to an
electrical junction box
Or when you need to cover paint gap
from the old thermostat.
5. Separate the Junction Box Adapter
from the Cover Plate. See Figure 5.
6. Mount the Junction Box Adapter to
the wall or an electrical box using any
of the eight screw holes. Insert and
tighten mounting screws supplied with
Cover Plate Kit. Do not overtighten.
Make sure the Adapter Plate is level.
See Figure 6.
7. Attach the UWP by hanging it on the
top hook of the Junction Box Adapter
and then snapping the bottom of the
UWP in place. See Figure 7.
8. Snap the Cover Plate onto the
Junction Box Adapter. See Figure 8.
Use 3x supplied
screws #8 1-1/2”
Use 2x
supplied
screws
#6 5/8”
2
4
8
76
5
3
Terminal designations
Conventional Systems Heat pump systems
Terminal Description Terminal Description
S/S Universal input for a wired
indoor, outdoor sensor S/S Universal input for a wired
indoor, outdoor sensor
Y Compressor Stage 1 Y Compressor Stage 1
Y2 Compressor Stage 2 Y2 Compressor Stage 2
G Fan Relay G Fan Relay
C
24VAC Common wire from
secondary side of cooling
transformer (if 2 transformers)
C
24VAC Common wire from
secondary side of cooling
transformer
K* Connect to K on Wire Saver
Module K* Connect to K on Wire Saver
Module
U/U** Universal relay for ventilation U/U** Universal relay for ventilation
A L/A Connect to compressor
monitor
W Heat Stage 1 O/B Changeover valve for heat
pumps
W2 Heat Stage 2 Aux Backup Heat
E Emergency Heat
R 24 VAC Heating transformer R 24 VAC Heating transformer
Rc 24 VAC Cooling transformer Rc 24 VAC Cooling transformer
* The THP9045A1023 Wire Saver Module is used on heat/cool systems when you only have four wires
at the thermostat and you need a fifth wire for a common wire. Use the K terminal in place of the Y and
G terminals on conventional or heat pump systems to provide control of the fan and the compressor
through a single wire—the unused wire then becomes your common wire. See THP9045 instructions
for more information.
** Ventilation is not available on all models. When the U slider is in the down position (2 wires), the U
contacts are a dry set of contacts. If your ventilation system requires 24 volts, move the U slider to the
up position (1 wire). Lower U terminal is internally jumped to the Rc terminal. In this application, you
would hook up one wire from your damper to the upper U terminal and the other to the common side of
the transformer.
Wiring UWP
Push down on the tabs to put the wires into the inner holes of their corresponding termi nals
on the UWP (one wire per terminal) until they are firmly in place. Gently tug on the wires to
verify they are secure. If you need to release the wires again, push down the terminal tabs
on the sides of the UWP.
This wiring is just an example,
yours may vary.


Specyfikacje produktu

Marka: Honeywell
Kategoria: termostat
Model: Lyric T6
Kolor produktu: Czarny
Typ kontroli: Dotyk
W zestawie pilot zdalnego sterowania: Nie
Typ ekranu: LCD
Podświetlenie: Tak
Podświetlenie wyświetlacza: Tak
Funkcja pamięci: Nie

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Honeywell Lyric T6, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje termostat Honeywell

Instrukcje termostat

Najnowsze instrukcje dla termostat