IMPORTANT SAFETY
INSTRUCTIONS
READ AND SAVE THESE
SAFETY INSTRUCTIONS
BEFORE USING THIS AIR
PURIFIER
When using electrical appliances, basic
precautions should always be followed to
reduce the risk of fire, electric shock, and
injury to persons, including the following:
1. Read all instructions before operating the air
purifier.
2. Place air purifier where it is not easily knocked
over by persons in the household.
3. Always turn the air purifier controls to the OFF
position and unplug from the wall outlet when
not in use.
4. To disconnect the air purifier, press the Power
button ( ) to turn the unit off, grip the plug
and pull it from the wall outlet. Never pull by
the cord.
5. Do not use any product with a damaged cord
or plug or if product malfunctions, is dropped
or damaged in any manner. Keep the cord
away from heated surfaces.
6. Do not use air purifier outdoors.
7. Never use air purifier unless it is fully
assembled.
8. Do not run power cord under carpets, and do
not cover with throw rugs. Arrange cord such
that it will not be tripped over.
9. Do not use air cleaner where combustible
gases, vapors or an oxygen rich environment
are present.
10. Do not expose the air purifier to rain, or use
near water, in a bathroom, laundry area or
other damp location.
11. The air purifier must be used in its upright
position.
12. Do not allow foreign objects to enter ventilation
or exhaust opening as this may cause electric
shock or damage to the air purifier. Do not
block air outlets or intakes.
13. Locate air purifier near the outlet and avoid
using an extension cord.
14. This appliance has a polarized plug (one blade
is wider than the other). To reduce the risk of
shock, this plug is intended to fit only one way
in a polarized outlet. If the plug does not fit
fully in the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature.
15. A loose fit between the AC outlet (receptacle)
and plug may cause overheating and a
distortion of the plug. Contact a qualified
electrician to replace loose or worn outlet.
16. Do not sit, stand or place heavy objects on the
air purifier.
17. Disconnect power supply before servicing.
WARNING: To Reduce The Risk of Fire or
Electric Shock, Do Not Use This Air Purifier
With Any Solid-State Speed Control Device.
The sealed UV bulbs contain a small
amount of mercury. Dispose of these items
at household hazardous waste collection
sites only. If the UV bulb breaks, do not
vacuum or handle with your bare hands.
HEPA CLEAN
WHISPER QUIET
AIR PURIFIER
WITH UV LIGHT
For Model Series HHT-145
HHT-145_OM.qxd 11/21/06 5:42 PM Page 1
YOUR AIR PURIFIER
HOW YOUR AIR PURIFIER WORKS
ODOR CONTROL
This model air purifier incorporates a 4-stage cleaning
system to help clean the air that passes through the filter
in the unit (Fig. 1).
Stage 1: Washable Particle Pre-Filter or Replaceable
Odor Control Filter
Stage 2: UV light that can be turned on or off
Stage 3: 99% HEPA-Type Filter with antimicrobial
treatment
Stage 4: Electronic Ionizer that can be turned on or off
Ultraviolet Light
Fig. 1
Control Panel
HEPA-
Type
Filters
(2)
Washable
Pre-filter (1)
OR
Optional
Odor
Reducing
Pre-filter
Rear
Grille
This air purifier includes a special odor reducing pre-filter. In order to enjoy the benefits of enhanced odor
control, replace the pre-filter that is already in the air purifier with the odor control filter.
For optimal performance, the filters are wrapped in plastic to keep them fresh. Filter replacement timing
will be approximately 3 months, depending on use.
Call 1-800-477-0457 or visit www.kaz.com to order your replacement CZ odor control filters.
HHT-145_OM.qxd 11/21/06 5:42 PM Page 2
OPERATION
Powering Up: (Fig. 3)
Plug the air purifier into a grounded, working outlet. Once the
unit is plugged in, the back-lit Power Button icon ( ) will blink
for 12 seconds indicating the unit is ready for operation.
When the Power Button is pressed the following will
take place:
°The LCD display and buttons will light up. The Oscillation,
on/ off, Timer, and Timer +/– button lights will turn off after
3 seconds. The LCD light will turn off after 8 seconds if no
buttons are pressed.
°The UV feature turns on.
°The Ionizer feature turns on.
°The air purifier will operate at a medium cleaning power
level for a few seconds and then automatically change
to a low level.
°The continuous Run display turns on and rotates.
Fig. 3
INSTALL HEPA-TYPE FILTERS
The HEPA-Type Filters are supplied within the air purifier. They are wrapped to ensure purity.
Make sure the air purifier is turn off and unplugged.
Remove the rear grille by pressing the notch on the top of the rear grille and
pulling the grille towards you (Fig. 2).
Remove the filters by gently pushing along the edge of the filter frame and
pulling it forward. Repeat for the second filter.
Remove the protective wrap from the filters.
Place the filters back into the air purifier housing and snap the rear grille back
into place.
Note that the pre-filter needs to be in position along the rear grille before snapping
the grille back into place.
The Top filter must be in place in order for the unit to operate.
Fig. 2
SET-UP
Select a firm, level and flat location. For proper airflow, locate the unit at least 3 feet (1 M) from any
wall or furniture.
When operating, large volumes of air are drawn toward the air purifier. Surrounding areas should be
cleaned and/or vacuumed frequently to prevent build-up of dust and other contaminates. This may also
help prolong the life of the filter. If the unit is placed on a light colored carpet, a small mat or rug should
be used underneath to prevent permanent staining. This is especially important in homes with
contamination from smoking, fireplaces or where candles are burned.
Ensure the exit grille (front of the unit) faces away from the closest wall or furniture.
Ensure no grilles are blocked.
Ionization
on/off button
UV on/off button
Filter reset
button
UV bulb reset
button
Power button
Cleaning power
+/- button
Oscillation
button
Timer
+/– button
Timer
on/off
button
LCD display
HHT-145_OM.qxd 11/21/06 5:42 PM Page 3


Specyfikacje produktu

Marka: Honeywell
Kategoria: oczyszczacz powietrza
Model: HHT-145

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Honeywell HHT-145, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje oczyszczacz powietrza Honeywell

Honeywell

Honeywell F116A1120 Instrukcja

29 Września 2024
Honeywell

Honeywell F120 Instrukcja

29 Września 2024
Honeywell

Honeywell F118 Instrukcja

29 Września 2024
Honeywell

Honeywell HPA5200 Instrukcja

28 Września 2024
Honeywell

Honeywell HPA5100 Instrukcja

28 Września 2024
Honeywell

Honeywell HPA-245 Instrukcja

28 Września 2024
Honeywell

Honeywell HHT-080 Instrukcja

28 Września 2024
Honeywell

Honeywell HPA180 Instrukcja

28 Września 2024

Instrukcje oczyszczacz powietrza

Najnowsze instrukcje dla oczyszczacz powietrza

Ulsonix

Ulsonix AIRCLEAN 20G Instrukcja

15 Października 2024
Winix

Winix AUS-5500 Instrukcja

14 Października 2024
Gorenje

Gorenje H08WB Instrukcja

9 Października 2024
Ufesa

Ufesa PF4500 Instrukcja

9 Października 2024
Ufesa

Ufesa PF3500 Instrukcja

9 Października 2024
Samsung

Samsung AX32BG3100GB Instrukcja

9 Października 2024
GE

GE AHG50LE Instrukcja

9 Października 2024
Miele

Miele PAC 1200 Instrukcja

9 Października 2024