1. Battery Installation
1) Use the included the T10 Torx tool unscrew battery cover screw until the battery to
cover can be opened as shown in Fig 2.
2) Inspect the battery compartment for dirt, moisture, or corrosion, and then clean
the battery compartment if needed.
3) Inspect the O-ring seal on the battery cover to make sure that it is free of sand and
dirt particles and that it has not been damaged.
4) Install the battery as marked on the battery compartment floor with the ribbon
under the battery cell to help with future battery removal. (See Fig 2 ).
5) After installing the battery, close the battery cover and use the included the T10
Torx tool rotate the battery cap screw until secure .to clockwise
Caution:
The P.ID includes a flat top 18350 Li-ion battery which requires use of the included
charging cable or a high quality charger only. Frequently inspect the condition of the
battery, including the terminals and outer shrink wrap. Do not use a battery with
signs of damage.
1) High Power White LED with Visible Laser (DUAL includes IR Laser)
2) Rechargeable 18350 battery
3) Magnetic Charging Port
4) CNC Milled 7075 Aluminum Housing
5) IP68 Dust and Waterproof
6) 2 Rail Interface Adapters
www.holosun.com
WEAPON LIGHT + LASER SIG HT
P.ID PLUS
P.ID DUAL
System Description
Battery
Thank you for purchasing the P.ID PLUS/DUAL from HOLOSUN The P.ID .
PLUS/DUAL is a weapon combines a visible laser (PLUS) or visible light system that
and IR laser (DUAL) high-power LED designed for Positive with a white light
IDentification in all-weather and . lighting conditions The P.ID PLUS/DUAL attaches
to any firearm that uses a MIL-STD 1913 Picatinny rail and includes adapters for
universal compatibility. This product is a Class III laser. Before operation, please
read the User's Manual carefully:
2. Battery Recharging
1) The recharging voltage for the P.ID PLUS/DUAL is DC5V.
2) Connect the USB end of the charging cable to an external USB power source,
then attach the opposite end of the magnetic charging cable to the charging port of
the sight (See Fig 3)..
I. Red indicator light: charging
ii. Green indicator light: fully charged
Caution:
Do not connect the charger if there is no battery installed.
Do not use a disposable battery.
Please keep the charging port clean, wipe any dust or debris away before charging.
The P.ID PLUS/DUALcan only be charged with the included magnetic charging
cable, that is not compatible with other MCC cables.
Fig 2
2
WARNING:
1. Do not point the light or laser towards human eyes.
This may cause temporary, or permanent damage to
the eyes.
2. Do not look into the laser through binoculars or
telescopes.
Important Notices
1. Component Description
2. Packaging
The P.ID PLUS/DUAL packaging includes the following items:
1) P. ID PLUS or DUAL Light w/ Laser Sight(s)
2) User Manual
3) 2 Rail Interface Adapter Inserts(Adapter 1 is installed on the product)
4) T10 Torx Tool
5) USB Magnetic Charging Cable
6) Flat Top 18350 Battery
when the light is on. The radiant energy of the light may cause damage to the light
itself, or even result in burning other materials.
5. Do not leave the light in any type of fabric bag or fusible plastic container under
high temperature.
CAUTION:
1. Ensure the firearm is unloaded and safe by removing all ammunition and
magazines from firearm and verifying an empty chamber before installation and
battery replacement. DO NOT ATTEMPT TO INSTALL THIS SIGHT KIT ON A
LOADED FIREARM.
2. Remove the P.ID PLUS/DUAL from the firearm and ensure the light is OFF before
performing any inspections.
3. Please remove the battery before storing the light for a long period of time.
4. Please keep the packaging should you need to make a warranty claim.
1
User Manual
Features
Fig 3
Battery
Compartment
Battery
Battery Insulation
Material
Battery Cover
O-Ring Seal
Screw
THIS PRODUCT COMPLIES WITH 21CFR PARTS
1040.10 AND 1040.11 EXCEPT FOR DEVIATION
PURSUANT TO LASER NOTICE 50 DATED JUNE 24,2007.
THIS PRODUCT COMPLIES WITH IEC
60825-1:2007-03 ED. 2.0 AND IEC
60825-1:2014-05 ED. 3.0
WARNING VISIBL E AND INVISIBLE
LASER RADIATIO N
DO NOT STARE INTO THE BEAM OR VIEW
DIRECTLY WITH OPTICAL INSTRUMENTS
CLASS II LASER PRODUCT
0.7mW @800-860nm CW
ÿ
AVOID DIRECT EYE EXPOSURE
CLASS 3R LASER PRODUCT
5mW@500-670nm CW
ÿ
Fig 1
1 Bezel 9 VIS Windage Adjustment
2 Body 10 IR Windage Adjustment(DUAL)
3 Adapter Insert 11 IR Elevation Adjustment(DUAL)
4 Clamping Block 12 VIS Elevation Adjustment
5 Locking Screw 13 Battery Compartment Screw
6 Magnetic charging port 14 Battery Compartment
7 Mode Indicator(DUAL) 15 Bottom Activation Buttons
8 Charging Indicator 16 Top Activation Buttons
6
7
9
13
16
16
15
1
2
345
8
12
11
10
15
Charging Indicator
Magnetic charging
port
Mode
Indicator
(DUAL)
3. Do not point the laser beam at reflective surfaces.
4. Do not cover the light head, or place the light head down on the ground
Installation
1. Installation on an Accessory Rail
1) Using the included T10 torx tool, loosen the clamp block in order to install the P.ID
PLUS/DUAL on the accessory rail.
2) Press the head of the clamp screw to open up the rail clamp to it’s maximum width.
Fig 5
We provide a limited lifetime warranty from the date of purchase on parts and
workmanship to the original purchaser. At our sole discretion, we will repair or
replace products found to be defective under normal use without charge, excluding
any delivery costs, which will be born by purchaser. We will not be liable for
incidental, consequential, or special damages arising out of or in any connection
with the use or performance of this product. This warranty is void if the product has
been misused, modified, neglected, or disassembled prior to its return. Please refer
to www.holosun.com for current and complete warranty information and other
conditions.
The P.ID series is a rugged and compact light that is designed to operate in severe
environments. The following tips are provided to ensure a long product life. When
cleaning the lens, ensure it has cooled before any maintenance. Blow away any dust
on the surface, wet the lens with lens cleaner or clean water, then wipe away
smudges with lens tissue, soft cotton or a microfiber cloth. Avoid touching the glass
surface with dry cloth or tissue paper. Do not use organic solvents such as alcohol or
acetone. No special maintenance is needed for the housing surface. Do not try to
dismantle the device as the internal parts are specially cleaned and sealed and with
an anti-fog treatment. Any such attempt will void the warranty.
Fig 7
For more information about Holosun, our Terms of Use and Sale, and our
Privacy Policy, please visit holosun.com.
Phone: 909-594-2888
Fax: (909) 598-4888
Email: warranty@holosun.com
Holosun Technologies Inc.
Ver:A0
P.ID operation
Zero Setting
Maintenance & care
3
Fig 4
2) Insert the other adapter into the slot on top of the P.ID PLUS/DUAL and tighten the
adapter screw clockwise .
3) Place the fixed side of the rail clamp against the firearm rail, use the included tool
to turn the clamp screw head clockwise completely until the P. ID PLUS/DUAL is
secured onto the rail and cannot be moved forward or back. See Fig 5
3) Place the fixed side of the rail clamp against the firearm rail
and swing the light into position until the recoil lug of the rail interface insert fully
engages a slot in the accessory rail. Then press the clamp block so that it grabs onto
the rail.
4) Whilepushingforward on the P ID PLUS/DUAL(toward thefirearm muzzle), turn .
the clamp screw clockwise completely untilthe P ID PLUS/DUAL is secured onto the .
rail andcannotbe moved forwardorback S e Fig 4 . .
e
There are two sets of activation buttons at the rear of the P.ID PLUS/DUAL. The top
b activate activate the . See Fig 6uttons the white light, and bottom buttons laser
1. Constant On: A short press of either activationbutton (left or right), will activate
the , depending on mode. A second short press of either activation light and/or laser
button (left or right) will turn the light and/or laser off.
2. Momentary On: activation Press and hold either button (left or right) for more
than 0.5s, and the and/or laser buttonlight will remain on until you release the
3. Operation mode: bottompress and hold both the activation buttons
simultaneously for 3s to cycle through + (default), , IR, and WL VIS PLUS DUAL
modes.
a. W + mode: L VIS the indicator is off, the top buttons LED activate white light, and
the bottom buttons activate VIS laser.
b. P mode: LUS the indicator is blue, LED all four buttons activate both white light and
VIS laser simultaneously.
c. IR mode: the indicator is green, LED top buttons are disabled and bottom buttons
activate IR laser only. (P.ID DUAL only)
d. D mode: UAL the indicator is red, the top buttons LED activate white light and VIS
laser, and the bottom buttons activate IR laser. (P.ID DUAL only)
4) Power Settings:
All P.ID models have high/low power settings
To change the power setting, press and hold the light (top) activation buttons
simultaneously, the P.ID PLUS/DUAL will alternate between high and low power
every one-second.
P.ID PLUS: High Mode output is 900 Lumens/20,000 Candela, Low Mode is 450
Lumens/10,000 Candela.
P.ID DUAL: High Mode output is 800 Lumens/17,000 Candela, Low Mode is 400
Lumens/8,500 Candela.
1. The elevation adjustment screws (U, D) are located on the lower part of the
housing and the windage adjustment screws (L, L) are located on the left and right
sides of the housing (see figure 7). Before leaving the factory, the sight has been
mechanically zeroed to approximately 25 yards.
2. Adjustments can be performed by inserting the flat-tipped end of the included
multi-tool into the slotted adjustment turret and rotating.
3. When adjusting vertically and horizontally, the corresponding relationship
between rotation direction and laser pointer movement is shown in the table below.
The U, D, and L markings reference the point of impact change, not the laser
movement direction.
The maximum adjustment range is 60MOA.±
Caution: If you feel the knobs can no longer be rotated, you may
have reached the mechanical limit of the adjustment turret.
Do not try to rotate the knobs further if you feel a bind or you may cause damage.
Limited Lifetime warranty
Clamp Block
Clamp ScrewH ead
Adapter Springs
Screw
Top left
button Top right
button
Bottom left
button
Bottom right
button
Fig 6
2. Selecting the Proper Adapter
The P.ID PLUS/DUAL comes with 2 adapters , Marked
as 1 and 2 respectively. See Fig 5. Both adapters are
meant for any firearms with MIL-STD 1913 or similar rail.
To change out the rail interface adapter the P.ID
,
PLUS/DUAL must be removed from the accessory rail.
Select the adapter which matches the angle of your
accessory rail.
1) Use the included tool adapterto turn the screw
counterclockwise to remove the adapter screw, then
remove the adapter by pulling is straight out.
Caution:
If the battery voltage is below 2.7V, the sight will shut down automatically after 2s
delay.
Low Battery Warning(P.ID DUAL only): If the battery voltage is below 2.9Vdc, the
laser beam will blink once every 10s.
1.51
1.51
Adapter 1
1.75
Adapter 2
Mode Adjuster Direction Pointer
Movement
VIS
Elevation
Adjusting
(U)
CW Up
CCW Down
Windage
Adjusting
(L)
CW Left
CCW Right
IR
Elevation
Adjusting
D)
CW Up
CCW Down
Windage
Adjusting
(L)
CW Left
CCW Right
IR Elevation
Adjustment
IR Windage
Adjustment
VIS Elevation
Adjustment
WIS Windage
Adjustment
5) Lockout:
The Lockout function disables all
functions to prevent unintentional light
and/or laser discharges. Triple tap one of
the top activation buttons to activate the
lockout. The white light will blink once
and power off the unit disabling all
buttons. Repeat process to deactivate
the Lockout.


Specyfikacje produktu

Marka: Holosun
Kategoria: Nie skategoryzowane
Model: P.ID Plus

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Holosun P.ID Plus, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Nie skategoryzowane Holosun

Instrukcje Nie skategoryzowane

Najnowsze instrukcje dla Nie skategoryzowane

IFM

IFM PE2599 Instrukcja

3 Kwietnia 2025
IFM

IFM RU6035 Instrukcja

3 Kwietnia 2025
Bestway

Bestway 9102S Instrukcja

3 Kwietnia 2025
Bestway

Bestway 9102T Instrukcja

3 Kwietnia 2025
Bestway

Bestway 21177 Instrukcja

3 Kwietnia 2025
Bestway

Bestway 21178 Instrukcja

3 Kwietnia 2025
Ruggard

Ruggard GTUV-SG Instrukcja

3 Kwietnia 2025