49W W W. H AY WA R D F L O W C O N T R O L . C O M 1 . 8 8 8 . 4 2 9 . 4 6 3 5
HOUSING
Polyamide
OUTPUT SHAFT
Carbon Steel, Nickel Plated
MINIMUM AIR
PRESSURE
80 PSI
MAXIMUM AIR
PRESSURE
120 PSI
SEALS
Nitrile
CYCLE TIME
Half Second, Typical
AIR PORT
CONNECTIONS
1/4" NPT
TECHNICAL INFORMATIONTECHNICAL INFORMATION
SPECIFICATIONS
PMD Series
Double Acting
Pneumatic Actuators
ES UP TO 2"
Y VALVES UP TO 3"
ES
to-Open and Close
nt Thermoplastic Housing
icated Rack and Pinion
and Pinion Design
Works Mounting
noid Mounting
g Base
ith Optional Voltages
ual Override
Auxiliary Limit Switch
• Cycle Speed Control
• Positioner
EXPLODED VIEW
P N E U M AT I C A C T U AT I O N A N D C O N T R O L S
M
A
N
U
A
L
O
V
E
R
R
I
D
E
50
Hayward is a registered trademark
of Hayward Industries, Inc.
© 2020 Hayward Industries, Inc.
USA: 1.888.429.4635 Fax: 1.888.778.8410 One Hayward Industrial Drive Clemmons, NC 27012 Email: hfcsales@hayward.com
Canada: 1.888.238.7665 Fax: 1.905.829.3636 2880 Plymouth Drive • Oakville, ON L6H 5R4 • Email: hflowcanada@hayward.com
Visit us at: haywardflowcontrol.com
TOP
FRONT
SIDE
BOTTOM
U
L
R
D
P
øC
B
øA
A
TECHNICAL INFORMATION, CONTINUED
PMD Series
Double Acting Pneumatic Actuators
FOR BALL VALVES UP TO 2"
FOR BUTTERFLY VALVES UP TO 3"
DIMENSIONS
ACTUATOR OPERATING SYSTEMS
MODEL øA
in / mm
B
in / mm
C
in / mm
L
in / mm
P
in / mm
R
in / mm
PMD15 .551 / 14
ISO F05
1/4-20 x .512
UNC-ISO F05
ø1.969 / 50
ISO F05 6.299 / 4.370 / 3.386 / 160 111 86
Dimensions are subject to change without notice – consult factory for installation information
ACTUATOR SPECIFICATIONS
MODEL PMD15
Torque Output (in-lbs) @ 80 PSI 275
Enclosure Material Polyamide
Output Shaft Carbon Steel, Nickel Plated
Air Port Connections 1/4" NPT
Air Consumption (cu. in.) 22.0
Air Transfer Internal
Stroke Time (seconds) .5
Cycle Time 1/2 Second
Minimum Air Pressure 80 PSI
Maximum Air Pressure 120 PSI
Operation Rack and Pinion
Weight (lbs / ) 2.624 / kg 1.2
VALVE SELECTION CHART
SIZE*
in / DN
TB / TBH / CV / CVH SERIES
BALL VALVES
TW/LA SERIES
BALL VALVES
BYV SERIES
BUTTERFLY VALVES
1/2 - 2 PMD15 PMD15 N/A / 15 - 50
2 - 3 PMD15
* Actuator selection based on clean water @ 70°F
51W W W. H AY WA R D F L O W C O N T R O L . C O M 1 . 8 8 8 . 4 2 9 . 4 6 3 5
SPECIFICATIONS
HOUSING
Polyamide
OUTPUT SHAFT
Carbon Steel, Nickel Plated
MINIMUM AIR
PRESSURE
80 PSI
MAXIMUM AIR
PRESSURE
120 PSI
SEALS
Nitrile
CYCLE TIME
Half Second, Typical
AIR PORT
CONNECTIONS
1/4" NPT
TECHNICAL INFORMATION
PMS Series
Spring Return
Pneumatic Actuators
FOR BALL VALVES UP TO 2"
KEY FEATURES
Air to Spring Fail-Safe Operation
• Corrosion-Resistant Thermoplastic Housing
• Permanently Lubricated Rack and Pinion
• Manual Override
Two-Piston Rack and Pinion Design
• Namur-Style Top-Works Mounting
• Namur-Style Solenoid Mounting
• Position Indicator
• Lightweight
• ISO5211 Mounting Base
OPTIONS
• Solenoid Valves with Optional Voltages
• Declutchable Manual Override
Auxiliary Limit Switch
• Cycle Speed Control
• Positioner
EXPLODED VIEW
M
A
N
U
A
L
O
V
E
R
R
I
D
E
P N E U M AT I C A C T U AT I O N A N D C O N T R O L S


Specyfikacje produktu

Marka: Hayward
Kategoria: Niesklasyfikowane
Model: PMD15

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Hayward PMD15, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Hayward

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024