GLO-RAY®
Pizza Warmer
GRPWS Series
Installation and Operating Manual
P/N 07.04.315.00
© 2012 Hatco Corporation
Register Online!
(see page 2)
www.hatcocorp.com
Do not operate this equipment unless you
have read and understood the contents of
this manual! Failure to follow the
instructions contained in this manual may
result in serious injury or death. This
manual contains important safety
information concerning the maintenance,
use, and operation of this product. If
you’re unable to understand the contents
of this manual, please bring it to the
attention of your supervisor. Keep this
manual in a safe location for future
reference.
No opere este equipo al menos que haya
leído y comprendido el contenido de este
manual! Cualquier falla en el seguimiento
de las instrucciones contenidas en este
manual puede resultar en un serio lesión
o muerte. Este manual contiene
importante información sobre seguridad
concerniente al mantenimiento, uso y
operación de este producto. Si usted no
puede entender el contenido de este
manual por favor pregunte a su
supervisor. Almacenar este manual en
una localización segura para la referencia
futura.
Ne pas utiliser cet équipement sans avoir
lu et compris le contenu de ce manuel !
Le non-respect des instructions
contenues dans ce manuel peut entraîner
de graves blessures ou la mort. Ce
manuel contient des informations
importantes concernant l'entretien,
l'utilisation et le fonctionnement de ce
produit. Si vous ne comprenez pas le
contenu de ce manuel, veuillez le signaler
à votre supérieur. Conservez ce manuel
dans un endroit sûr pour pouvoir vous y
référer plus tard.
WARNING
ADVERTENCIA
AVERTISSEMENT
Model
Width
(A)
Depth
(B)
Height
(C)
Footprint
Width (D)
Footprint
Depth (E)
Shelf
Height (F)
GRPWS-2418T 23-7/8″
(606 mm)
20-1/16″
(509 mm)
29-11/16″
(754 mm)
20-1/8″
(511 mm)
15-3/8″
(391 mm)
4-1/8″
(104 mm)
GRPWS-3618T 35-7/8″
(911 mm)
20-1/16″
(509 mm)
29-11/16″
(754 mm)
32-1/8″
(816 mm)
15-3/8″
(391 mm)
4-1/8″
(104 mm)
GRPWS-4818T 47-7/8″
(1216 mm)
20-1/16″
(509 mm)
29-11/16″
(754 mm)
44-1/8″
(1121 mm)
15-3/8″
(391 mm)
4-1/8″
(104 mm)
GRPWS-2424T 23-7/8″
(606 mm)
26-1/16″
(662 mm)
30-3/4″
(781 mm)
20-1/8″
(511 mm)
21-3/8″
(543 mm)
4-1/8″
(104 mm)
GRPWS-3624T 35-7/8″
(911 mm)
26-1/16″
(662 mm)
30-3/4″
(781 mm)
32-1/8″
(816 mm)
21-3/8″
(543 mm)
4-1/8″
(104 mm)
GRPWS-4824T 47-7/8″
(1216 mm)
26-1/16″
(662 mm)
30-3/4″
(781 mm)
44-1/8″
(1121 mm)
21-3/8″
(543 mm)
4-1/8″
(104 mm)
SPECIFICATIONS
Form No. GRPWSM-1012
8
Dimensions GRPWS-XXXXT Models
C
Side ViewRear View
E
B
D
A
F
GRPWS-XXXXT Dimensions
Height (C) includes 4″ (102 mm) legs. Subtract 4″ (102 mm)
from Height (C) if unit is sealed to countertop.
INSTALLATION
Form No. GRPWSM-1012
10
General
Hatco Glo-Ray®Pizza Warmers are shipped with most
components pre-assembled. Care should be taken when
unpacking shipping carton to avoid damage to the unit and
components enclosed.
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate unit indoors where ambient air temperature is a
minimum of 70°F (21°C).
FIRE HAZARD: Locate unit a minimum of 1″ (25 mm) from
combustible walls and materials. If safe distances are not
maintained, discoloration or combustion could occur.
The National Sanitation Foundation (NSF) requires that
units over 36″ (914 mm) in width or weighing more than 80
lbs. (36 kg) either be sealed to or raised above the
installation surface. If unit cannot be sealed at the point of
use, 4 (102 mm) legs are included to allow for proper
cleaning access below unit.
1. Remove the unit from the carton. Two people are required
for this step.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
2. Remove tape and protective packaging from all surfaces of
unit.
Do not lay unit on the side with the control panel. Damage
to unit could occur.
3. Install the 1″ (25 mm) rubber feet or 4″ (102 mm) adjustable
legs. Two people are required for this step.
a. Carefully lay the unit on its side.
b. Install the feet or legs.
To install the 1″ (25 mm)
rubber feet:
Thread a foot stud into
the hole at each corner
on the bottom of the unit.
Tighten securely.
Slip a rubber foot over
each foot stud.
To install the 4″ (102 mm) adjustable legs:
Thread a leg into the
hole at each corner on
the bottom of the unit.
Hand-tighten the legs
until snug. Do not over-
tighten.
c. Return the unit to the upright
position.
NOTE: 4″ (102 mm) legs are
adjustable for leveling the unit. Use a 5/8″ (16 mm) open-
end wrench to make leveling adjustments once the unit is
placed in final position.
4″ Leg
Adjustable Tip
Foot
Stud
Rubber
Foot
4. Slide each side glass panel into the upper channel, then
gently lower the panel into the lower channel.
Side Glass Panel Installation (GRPWS-XXXXD shown)
5. Install the box stop w/sign holder on each shelf. To install:
a. Position the box stop on the shelf
b. Secure the box stop at each end using the supplied
thumbscrews.
Box Stop w/Sign Holder Installation (GRPWS-XXXXT shown)
NOTE: Unit must be transported in the upright position.
6. Place the unit in the desired location.
Locate the unit in an area where the ambient air
temperature is constant and a minimum of 70°F
(21°C). Avoid areas that may be subject to active air
movements or currents (i.e., near exhaust fans/hoods
and air conditioning ducts).
Make sure the unit is at the proper counter height in an
area convenient for use.
Make sure the countertop is level and strong enough to
support the weight of the unit and food product.
Make sure all the feet/legs on the bottom of the unit are
positioned securely on the countertop.
Box Stop
w/Sign Holder
Thumbscrew
Upper Channel
Side
Glass
Panel
Lower Channel


Specyfikacje produktu

Marka: Hatco
Kategoria: Płyta rozgrzewająca
Model: Glo-Ray GRPWS-4824Q

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Hatco Glo-Ray GRPWS-4824Q, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Płyta rozgrzewająca Hatco

Instrukcje Płyta rozgrzewająca

Najnowsze instrukcje dla Płyta rozgrzewająca

Royal Catering

Royal Catering RC-SHSFL09 Instrukcja

14 Października 2024
Hendi

Hendi 238868 Instrukcja

9 Października 2024
Rommelsbacher

Rommelsbacher WPR 307/E Instrukcja

8 Października 2024
Salton

Salton ICS2146 Instrukcja

7 Października 2024
Salton

Salton TWT30 Instrukcja

7 Października 2024
Salton

Salton SMW2094BKW Instrukcja

7 Października 2024
Salton

Salton SP2111 Instrukcja

7 Października 2024
BEEM

BEEM Buffet Star 2 in 1 Instrukcja

5 Października 2024
Brentwood

Brentwood BF-215 Instrukcja

4 Października 2024