Operating Instructions
PROFITESTEMOBILITY
Adapter for Standards-Compliant Testing of Single and 3-Phase,
Mode 2 and 3 Charging Cables with Simulation of Faults 3-349-981-15
6/8.21
Important
Read carefully before use!
Keep on file for future reference!
Please observe the manufacturer‘s details
on the devices under test!
2 Gossen Metrawatt GmbH
Connections Overview
1N2: Input sockets for 3-phase mains
connection with the help of a CEE
adapter (16 A, 32 A with five 4 mm
safety sockets) and mains connection
fuses F1, F2 and F3 for the 3 phases
2N1: Inlet plug for mains connection,
mains connection fuses FLN for L and N
3IN2: Socket (MENNEKES) for connecting
a 3-phase, mode 3 charging cable
(charging station end) via a type 2
charging plug
4ICCB-IN1*: Input sockets wired parallel to
connection sockets IN2, IN3 and IN4 for
connecting a test instrument for protec-
tive conductor and insulation measure-
ment
* ICCB = i c c bn- able ontrol ox: control box inside
the mode 2 charging cable
5 Rotary selector switches (S1 and S2):
See description on page 3.
6ICCB-OUT1*: Charging cable output sock-
ets wired parallel to OUT2 for connecting
a test instrument for protective conduc-
tor and insulation measurement
7IN2: Socket (MENNEKES) for connecting
a mode 2 charging cable (vehicle end)
via a type 2 charging plug
8IN3: Input socket in order to be able to
connect a charging cable with specific
plug per IEC 62196 or CEE plug
(charging station end) via adapter
9IN4: Earthing contact input socket for
connecting the supply plug of a single-
phase, mode 2 charging cable (charging
station end)
10
I
PE
:
Loop for measuring protective con-
ductor current with a current clamp
transformer
1
234
5
6
7
8
9
10
PROFITESTEMOBILITY Connections Overview
Gossen Metrawatt GmbH 3
Operating Overview
Meanings of Symbols on the Instrument
300 V CAT II
Maximum permissible voltage
and measuring category between
connections and ground
Warning concerning a point of
danger (attention: observe docu-
mentation!)
CE conformity marking
This device may not be disposed
of with the trash.
Further information regarding the
WEEE mark can be accessed on
the Internet at www.gossenme-
trawatt.com by entering the
search term “WEEE”.
Meanings of Symbols in the Operating Instruc-
tions
LED L1, L2, L3, N or PE at test adapter
LED on LED off
Scope of Delivery
1 Test adapter in case
1 Mains power cable
1 Set of operating instructions
Fault Selection
Interrupted
Reversed wires
Mains disconnect, mode 2/3 charging cable
– For RISO measurement
Mains connect, mode 2 charging cable
– For fault simulation
– For RPE measurement
– For tripping test with INom
and measurement of time to trip
Orange switch positions: testing at single-phase, mode 2/3 cables
Green switch positions: testing at 3-phase, mode 2/3 cables
Top Switch
Bottom Switch
Status B, C, E
Riso
phase
!
PROFITESTEMOBILITY Operating Overview – Symbols – Scope of Delivery


Specyfikacje produktu

Marka: Gossen Metrawatt
Kategoria: nieskategoryzowany
Model: PROFITEST E-MOBILITY

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Gossen Metrawatt PROFITEST E-MOBILITY, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Gossen Metrawatt

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024