Instrukcja obsługi Glow-worm Micron 120FF
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Glow-worm Micron 120FF (32 stron) w kategorii Gejzery. Ta instrukcja była pomocna dla 8 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/32
221954D.09.04
All replacement parts
All labour charges
All call-out charges
Thank you for installing a new Glow-worm appliance in your home.
Glow-worm appliances' are manufactured to the very highest standard so we are pleased
to offer our customers' a Comprehensive First Year Guarantee.
We recommend you complete and return your Guarantee Registration Card as soon as possible.
If this card is missing you can obtain a copy or record your registration by telephoning Glow-worm's own service
organisation on 01773 828100.
Our Guarantee gives you peace of mind plus valuable protection against breakdown by covering the cost of:
Guarantee Registration
Fanned Flue Boiler
This is a Cat I2H Appliance
To b e l e f t w i t h t h e u s e r
4272
❏
✔
❏
✔
❏
✔
Instructions for Use
Installation and Servicing
G.C. No. 41-047-52 G.C. No. 41-047-23
REGISTER YOUR GLOW-WORM APPLIANCE
FOR 1ST YEAR GUARANTEE PROTECTION
CALL 0800 073 2142
Micron
100FF 120FF
BS 6332
BS 5258
Reference in these instructions to British Standards and Statutory
Regulations/Requirements apply only to the United Kingdom.
For Ireland the current edition of I.S.813
"Domestic Gas Installations" must be used.
Tel: (01773) 828100
Fax: (01773) 828070
Glow-worm,
Nottingham Road, Belper, Derbyshire. DE56 1JT
General/Sales enquiries:
Tel: (01773) 824141 Fax: (01773) 820569
www.glow-worm.co.uk
The instructions consist of three parts, User, Installation and Servicing Instructions.
The instructions are an integral part of the appliance and must, to comply with the current issue of the Gas Safety
(Installation and Use) Regulations, be handed to the user on completion of the installation.
2
221954D
Important Information
Introduction 3
Lighting the Boiler 4
General Data 1 5
Flue Terminal 2 9
Water Systems 3 10
Flue and Appliance Preparation 4 12
Boiler Installation 5 14
Flue Fixing 6 16
Electrical Connectors 7 17
Commissioning 8 18
Instructions to the User 9 22
Servicing 10 22
Fault Finding 11 24
Replacement of Parts 12 28
Spare Parts 13 32
CONTENTS DESCRIPTION SECTION PAGE No.
INSTRUCTIONS
FOR USE
INSTALLATION
INSTRUCTIONS
SERVICING
INSTRUCTIONS
Testing and Certification
This boiler is tested and certificated for safety and performance. It is therefore important that no alteration is made to the boiler, without
permission, in writing, from Glow-worm.
Any alteration not approved by Glow-worm, could invalidate the certification, boiler warranty and may also infringe the current issue
of the Statutory Requirements, see Section 1.4.
CE Mark
This boiler meets the requirements of Statutory Instrument No. 3083 The boiler (Efficiency) Regulations, and therefore is deemed
to meet the requirements of Directive 92/42/EEC on the efficiency requirements for new hot water boilers fired with liquid or gaseous
fuels.
Type test for purposes of Regulation 5 certified by: Notified body 0086.
Product/production certified by: Notified body 0086.
The CE mark on this appliance shows compliance with:
1. Directive 90/396/EEC on the approximation of the laws of the Member States relating to appliances burning gaseous fuels.
2. Directive 73/23/EEC on the harmonization of the Laws of the Member States relating to the electrical equipment designed
for use within certain voltage limits.
3. Directive 89/336/EEC on the approximation of the Laws of the Member States relating to electromagnetic compatibility.
INFORMATION FOR THE INSTALLER AND SERVICE ENGINEER.
Under Section 6 of The Health and Safety at Work Act 1974, we are required to provide information on substances hazardous to
health.
Insulation Pads, Glass yarn.
These can cause irritation to skin, eyes and the respiratory tract. If you have a history of skin complaint you may be susceptible to
irritation. High dust levels are usual only if the material is broken. Normal handling should not cause discomfort, but follow normal
good hygiene and wash your hands before eating, drinking or going to the lavatory. If you do suffer irritation of the eyes or severe
irritation to the skin seek medical attention.
SPARE PARTS
REMEMBER: When replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and
performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by
Glow-worm.
3 221954D
Introduction
WARNING: It is important that the case (not the controls tray)
is not disturbed or removed other than for servicing by a
competent person.
Please read these instructions and follow them carefully for the
safe and economical use of your boiler.
The Micron FF series are fanned flue boilers designed to
provide central heating and indirect domestic hot water.
The boiler is fully automatic in operation having only one user
control, the control thermostat.
Gas Leak or Fault
Turn off the gas emergency control valve immediately. Eliminate
all sources of ignition, i.e. smoking, blowlamps, hot air guns etc.
Do not operate electrical lights or switches either on or off. Open
all doors and windows, ventilate the area.
Electrical Supply Failure
Failure of the electrical supply will cause the burner to go out.
Should this occur, operation of the appliance will normally
resume after the electrical supply is restored.
If the boiler does not relight after an electrical supply failure the
overheat safety cutoff device may need resetting, remove the
controls cover and press the reset button, refer to diagram 8.1.
Overheat Safety Cutoff
If the overheat safety cutoff device operates on any other
occasion than an electrical supply failure, press the reset button
as in “Electrical Supply Failure”. If the overheat operates again,
turn the appliance off and contact your installation/servicing
company.
Maintenance
To ensure the continued efficient and safe operation of the
boiler it is recommended that it is checked and serviced as
necessary at regular intervals. The frequency of servicing will
depend upon the particular installation conditions and usage,
but in general once a year should be enough.
If this appliance is installed in a rented property in the UK there
is a duty or care imposed on the owner of the property by the
current issue of The Gas Safety (Installation and Use)
Regulations, Section 35.
It is the law that any servicing is carried out by a competent
person.
To obtain service, please call your installer or Glow-worm’s own
Service Organisation using the telephone number given on the
controls tray.
Please be advised that the ‘Benchmark’ logbook should be
completed by the installation engineer on completion of
commissioning and servicing.
All CORGI Registered Installers carry a CORGI ID card, and
have a registration number. Both should be recorded in your
boiler Logbook. You can check your installer is CORGI registered
by calling CORGI direct on :- 01256 372300.
Boiler Clearances
If fixtures are positioned close to the boiler space must be left
as shown in diagram 1.2. At least a minimum clearance of
500mm must be left in front of the boiler to allow for servicing.
Boilers Installed in a Compartment or
Cupboard
If the boiler is installed in a compartment or cupboard do not
obstruct any ventilation openings.
Do not use the compartment or cupboard for storage.
Cleaning
WARNING: This appliance contains metal parts (components)
and care should be taken when handling and cleaning, with
particular regard to edges.
Clean the casing occasionally by wiping it over with a damp
cloth or dry polishing duster.
Do not use an abrasive cleaner.
Boiler Electrical Supply
WARNING: This boiler must be earthed.
The boiler must only be connected to a 230V~50Hz supply
protected by a 3A fuse.
All wiring must be in accordance with the current issue of
BS7671.
Wiring to the boiler must be PVC insulated type to the current
issue of BS6500 Table 16, not less than 0.75mm2
(24/0.20mm).
The colours of three core flexible cable are:
Brown - live, Blue - neutral,
Green/yellow - earth.
As the markings on your plug may not correspond with these
colours continue as follows:
The cable coloured blue must be connected to the terminal
marked “N” or black.
The cable coloured brown must be connected to the terminal
marked “L” or red.
The cable coloured green/yellow must be connected to the
terminal marked “E”, or green or the earth symbol .
Instructions for Use
Specyfikacje produktu
Marka: | Glow-worm |
Kategoria: | Gejzery |
Model: | Micron 120FF |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Glow-worm Micron 120FF, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Gejzery Glow-worm
3 Lipca 2024
2 Lipca 2024
Instrukcje Gejzery
- Gejzery Bosch
- Gejzery Ferroli
- Gejzery Infiniton
- Gejzery Buderus
- Gejzery Vaillant
- Gejzery Baxi
- Gejzery Worcester
- Gejzery Technika
- Gejzery Nefit
- Gejzery Tokyo Gas
- Gejzery Cointra
- Gejzery Sentry
- Gejzery Keston
Najnowsze instrukcje dla Gejzery
14 Października 2024
12 Października 2024
12 Października 2024
10 Października 2024
8 Października 2024
9 Sierpnia 2024
6 Sierpnia 2024
6 Sierpnia 2024
6 Lipca 2024
5 Lipca 2024