Instrukcja obsługi Giga Copper G4202T

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Giga Copper G4202T (5 stron) w kategorii Niet gecategoriseerd. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/5
G4202T
G.hn Master and Client
Quick start guide
For further informaon and purchase enquiries
please contact info@gigacopper.net
1. Introducon
With the G.hn modem G4202T you can easily extend
your network via exisng data and telephone cables.
The devices are also suitable for the distribuon of ber
opc connecons from the ONT to the router via exisng
telephone line.
The modem can use any type of cable - both twisted pair
and non-twisted pair - for data transmission and
achieves a speed of approx. 1500 Mbit/s (sum of both
transmission direcons).
The devices are always connected in pairs - a master and
a client. The master determines how fast the data is
transferred towards the client and back
(download/upload).
In networks with several clients, a G.hn switch can be
used instead of several master modems (see
Installaon). This enables the central administraon of
all G.hn components.
2. Package content
G4202T Master or G420 Client 2T
DC-12V/1A Power adapter
RJ11/RJ11 telephone cable , 4- wire (SISO and MIMO) 1.5m
TAE-F/RJ11 , 4- pole (SISO and MIMO) plug
3. Technical data
Dimensions : 103 * 66 * 27 : mm
Weight: 0,19 kg
Operang temperature: 0°C - 40°C
Power consumpon: < 3 Wa
4. G.hn Specicaon
G.hn Wave2, 2-200 MHz
Connecon type: SISO (1 wire pair, 2-200MHz) and
MIMO (2 wire pairs, 2- MHz) 100
Total bandwidth ca. 1500 Mbit/s
(Sum of Download and Upload)
Spling of the bandwidth variable ex works , :
70% Download (from master client) to
30% Upload (from client master) to
Maximum permissible aenuaon of the cable
connecon: 75dB
5. Interfaces
Panel and LED descripon
Labelling
Descripon
12V DC
Power input
RST
Recessed reset buon (15 Sec .)
LINE
G.hn port
G1, G2
2x 1 Gigabit Ethernet Port
PHONE
Analog phone port (RJ45)
PWR LED
Displays power availability
LINE LED
Status of the G.hn connecon
(Green - OK, Yellow - weak signal,
O - no connecon)
G1/G2 LED
Ethernet Connecon Status
6. Installaon
Variant 1 Point- - : one master and client – „ to Point “
Variant 2 Connecon to the Switch G4224T or G4200- 8T/4T
7. Connecon type and wire assignment on device (RJ45 plug)
The G.hn connecon can be established either via one wire pair (connecon type SISO PHONE ) or = G.hn prole “ 200MHz”
via two wire pairs (connecon type MIMO PHONE ). The connecon type must be = G.hn prole “ 100MHz MIMO”
congured via web interface in both modems or via the G.hn switch.
The default seng PHONE is one wire pair connecon (“ 200MHz”).
Wire assignment SISO
Wire assignment MIMO
8. Installaon notes
The wires of a pair can be connected straight or crossed.
Maximum range of the G.hn connecon depends on the type of cable used, the connecon type and the environment.
Typical values for a 0.5 mm twisted pair cable: connecon possible up to approx. 600/800 metres (SISO/MIMO),
maximum bandwidth of 1500 Mbit/s - up to approx. 100/200 metres (SISO/MIMO).
For longer cables ( approx. 100-150m), the bandwidth can be increased by up to 15% (SISO) resp. up to 25% (MIMO) up
by adjusng the signal level. For this purpose, the "Range opmizaon model" must be set to "Long" in the web
interface of both devices resp. the "LongRangeMode" seng must be acvated in the G.hn switch.
The negoated bandwidth can be queried via the web interface of the devices (see point 11).
The bandwidth split of the G.hn connecon is variable. It can be set between 80/20% and 20/80%. In the factory seng,
70% of the bandwidth is reserved for download (direcon master to client) and 30% for upload (direcon client to
master). The allocaon can be congured via master web interface (menu G.hn DownStream / UpStream Rao) resp. via
the G.hn switch.
9. Administraon
10. IP address
The devices do not require IP addresses from the local network segment during operaon, because they transmit the data
trac via the MAC addresses. In the factory seng, they do not obtain any addresses from the local DHCP server.
If desired, stac IP addresses can be congured or the DHCP client can be acvated ("IP" menu in the web interface).
11. Query of the negoated bandwidth
The negoated bandwidths for both transmission direcons can be queried via web interface of each modem. The values
shown are gross data transmission rates on physical layer (PHY). Transmission rate on applicaon layer is 15-20% lower.
Login via Webinterface
Connect your computer to the G.hn modem via the GE
port..
Assign a xed IP address to your computer, e.g.
192.168.10.100 (network mask 255.255.255.0).
Open a web browser and connect to 192.168.10.252 or
192.168.10.253
Login with the standard password: paterna
It is possible to loop through an analogue telephone line on the same line parallel to the G.hn signal. To do this,
connect the telephone line and the telephone to the PHONE connecons on the G.hn master and G.hn client.

Specyfikacje produktu

Marka: Giga Copper
Kategoria: Niet gecategoriseerd
Model: G4202T

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Giga Copper G4202T, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niet gecategoriseerd Giga Copper

Giga Copper

Giga Copper G4201TM Instrukcja

1 Października 2024
Giga Copper

Giga Copper G4202T Instrukcja

1 Października 2024

Instrukcje Niet gecategoriseerd

Najnowsze instrukcje dla Niet gecategoriseerd

Eltako

Eltako FUD61NP-230V Instrukcja

1 Października 2024
TechN

TechN RTX 2080 Instrukcja

1 Października 2024
Eltako

Eltako FT4F-rw Instrukcja

1 Października 2024
Eltako

Eltako FT4F-wg Instrukcja

1 Października 2024
Eltako

Eltako DSZ15DM-3x80A Instrukcja

1 Października 2024
Morrison

Morrison BL260E S2 Instrukcja

1 Października 2024