Instrukcja obsługi Geemarc AMPLICALL PSA200

Geemarc Niesklasyfikowane AMPLICALL PSA200

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Geemarc AMPLICALL PSA200 (2 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 7 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
Transmitter
1. Loudspeaker
2. Battery cover
3. Power slide switch
(Alert/o󰀨/arm)
4. Pressure sensor mat
1
2 3 4
5
8
9
7
6
Pressure sensor mat and alarm
DESCRIPTION
INSTALLATION
Inside your gift box you should nd the below elements:
- 1 user guide
- 1 pressure sensor mat and its transmitter
- 1 wireless receiver
- Batteries are not included.
- A mains adapter is available as a spare part (6V 0.3A)..
(Fig1) (Fig 2)
(Fig3)
(Fig 4)
(Fig 5)
FEATURES
AMPLICALL PSA 200
Box Content
Wireless receiver
1. Volume control (HI/LO)
2,4. Visual indicators (Flash when
triggered by transmitter)
3. Visual indicator (Flashes when
triggered by transmitter/ Lights up
when batteries are low)
5. Loudspeaker
8. “Learn” paring button
9. Battery cover
10. Screw
11. Holes to mount device onto a wall
6. Power slide switch (Alarm/
o󰀨/chime)
7. DC adaptor socket (6V
DC/0.3A)
Setting up the transmitter and placing
the pressure sensor mat.
Setting up the receiver
1. Slide open the transmitter’s battery compartment
and place a 9V battery type PP3 (not included) while
observing the correct polarity before replacing the
battery cover. (Fig1)
2. Connect the transmitter’s wire to that of the
pressure sensor pad. (Fig2)
3. Place the pressure sensor mat under the cushion
of the wheelchair of the person you are caring for.
(Fig3)
Note: The transmitter
can be installed
onto a wall. To
do so the bellow
instructions should
be followed.
4. Drill two holes horizontally, 44 mm apart.
5. Insert two wall plugs xing into the two holes.
6. Screw two screws into the plugs, hang the
transmitter on the support and slide it down to lock it.
1. Unscrew the screw that is on the back of the wireless
receiver and that holds the cover of the battery
compartment in place before sliding open the battery
compartment. (Fig4)
2. Place three 1.5V batteries ( type LR14 ) in the battery
compartment while observing the correct polarity, and
place the battery compartment back in place. (Fig5)
3. You can connect an AC adapter 6V DC 0.3A (not
included); plug length: 12mm; inside positive ID: 2.1mm;
outside negative OD: 5.5mm) to the alert, and install the
batteries as backup in case of power failure.
Note: The receiver is wall mountable.
A. Drill two holes horizontally, 36 mm apart.
B. Insert two wall plugs xing into the two holes.
C. Screw two screws into the plugs, hang the receiver on the
support and slide it down to lock it.
The Amplicall PSA200 consist of a battery powered pressure
sensor mat connected to a signal transmitter, and a wireless
signal receiver.
As soon as pressure stops being applied to the sensor mat, the
transmitter it is connected to will send a signal to the wireless
receiver which will immediately start ringing and ashing. The
receiver’s alarm volume can be set to high or low. The distance
between the transmitter and the receiver should not exceed 30
meters in open eld.
The pressure sensor mat, which is powered by a 9V battery
(not included) was designed to be placed on the wheelchair or
mattress of a person with reduced mobility. The alarm it needs to
be paired with, which can work either with batteries (not included)
or plugged into the mains (adaptor not included), alerts the
caregiver whenever the person p1-he or she cared for appears to no
longer be sitting or lying on the pressure sensor mat.
Extremely easy to use our product is suitable for households that
count a member with reduced mobility, nursing homes, hospitals
and other places where patients or residents are being cared for.
Distance in between cannot exceed 30 meters.
EVERYDAY USE
You need to sit on the pressure sensor mat before turning on the
transmitter, otherwise the alarm will start ringing.
When sitting on the pressure sensor mat, move the power slide
switch of the transmitter to the “ ” position. The transmitter will ALERT
sound 4 seconds later to indicate it is now working. As soon as the
transmitter detects that no pressure is being applied to the sensor
mat, it will send a signal to the wireless receiver to trigger its alarm
and ashing light. It will keep sending a signal every 40 seconds
until pressure is once again applied on the sensor mat.
When the power slide switch of the receiver is placed on the
CHIME” position, the receiver will ring and ash for 5 seconds
every 30 seconds each time it receives a signal from the transmitter
alerting it that no pressure is being applied on the sensor mat. The
receiver will keep ringing until it is turned o󰀨 or pressure is once
again applied on the sensor mat.
When the power slide switch of the receiver is placed on
the “ALARM” position, the receiver will ring and ash for 30
seconds every 10 seconds each time it receives a signal
from the transmitter alerting it that no pressure is being
applied on the sensor mat. The receiver will keep ringing
until it is turned o󰀨 or pressure is once again applied on the
sensor mat.
Note: when not used, the power switch of both the
receiver and transmitter should be moved to the “OFF”
position to prevent them from ringing and save battery
life.
OFF
CHIME
ALARM
ALERT ARM
+
OFF
CHIME
ALARM
ALERT ARM
+
PAIRING
The pressure sensor mat and wireless receiver are
delivered already paired. When setting them up for the
rst time, you should apply pressure on the sensor mat
to make sure this triggers the alarm, which ought to be
placed less than 30 meters away.
Material :
Plastic PVC
10
11
UGEnACPSA200
En
1
3
2
ALERT ARM
4
The middle LED (3) will start ashing to warn you that
the battery needs to be replaced.
For product support and help visit our
website at
www.geemarc.com
E-mail : help@geemarc.com
telephone 01707 387602
lines are open 09h00 to 16h00 Mon
to Fri
Parc de l’Etoile, 2 Rue Galilée, 59760
Grande-Synthe,France.
This product is made in China To
Geemarc Telecom
TECHNICAL CHARACTERISTICS
TROUBLE SHOOTING
As soon as you hear a short tone, you can release the “learn”
button. The wireless receiver is now in learning mode and
is ready to receive a pairing signal from your sensor mat’s
transmitter.
3. Move the power slide switch of your sensor mat’s
transmitter to either the “ALERT ARM” or “ ” position without
applying pressure to the mat.
4. If you hear four consecutive short tones coming from the
receiver, this means the pairing process has succeeded.
To unpair a wireless receiver, press and hold its “learn” button
for 12 seconds until you hear two long tones. This indicates
the receiver is no longer paired to any pressure sensor mat.
Range: 30-meter
Frequency: 433.92Mhz
Ringer volume:
- 75dB on the transmitter
85dB (HI) or 70dB (LO) on the receiver
Power:
One 9V battery (type PP3) for the transmitter
Three 1.5V batteries (type LR14) for the receiver
Up to 10 receivers for each transmitter
Radio frequency power < 250mW
Number of receivers for one transmitter: 10
1) If the receiver does not ring, make sure that:
2) If the receiver does not ring, make sure that:
1. The power slide switch of the receiver is either on the “ALARM” or
” positionCHIME
2. The power slide switch of the transmitter is either on the “ALERT
or “ ” positionARM
3. The transmitter and receptor are not more than 30 meters apart
4. There is no pressure applied to the sensor mat
5. The batteries don’t need to be changed
1. The power slide switch of the transmitter is either on the “ALERT
or “ ” positionARM
2. There is no pressure applied to the sensor mat
3. The batteries don’t need to be changed
WARRANTY
From the moment your Geemarc AMPLICALL PSA 200 product
is purchased,Geemarc guarantee it for the period of two years.
During this time, all repairs or replacements (at our discretion)
are free of charge. Should you experience a problem then
contact our Helpline or visit our website at www.geemarc.
com. The guarantee does not cover accidents, negligence or
breakage to any parts. The product must not be tampered with
or taken apart by anyone who is not an authorised Geemarc
representative. The Geemarc guarantee in no way limits your
legal rights.
Important: YOUR RECEIPT IS PART OF YOUR
GUARANTEE
AND MUST BE RETAINED AND PRODUCED IN THE EVENT
OF A WARRANTY CLAIM.
Please note: The guarantee applies to the United Kingdom
only.
Geemarc Telecom SA hereby declares that this AMPLICALL
PSA 200 is in compliance with the essential requirements and
other relevant provisions of the Radio Equipment Directive
2014/53/UE.
The declaration of conformity may be consulted at
www.geemarc.com
UKCA DECLARATION
The symbol on the product or its packaging indicates that this
product may not be treated as household waste. Instead it
should be handed over to the applicable collection point for the
recycling of electrical and electronic equipment. By ensuring this
product is disposed of correctly, you will help prevent potential
negative consequences for the environment and human health,
which could otherwise be caused by inappropriate waste
handling of this product. For more detailed information about
recycling this product, please contact your local council o󰀩ce,
your household waste disposal service or the shop where the
product was purchased.
Disposal of old electrical & electronic equipment
(applicable in the European Union and other
European countries with separate collection
systems)
DISPOSAL INFORMATION
1. Move the receivers power slide switch to either the
” or “ ” position. You will hear a tone. It ALARM CHIME
indicates that the receiver has been activated and is now in
standby mode.
2. When in standby mode, you can use the tip of a pencil or a
screwdriver to press and hold the “learn” button that is on the
back of the wireless receiver for about 3 seconds.
You can pair up to 10 wireless receivers to a single pressure
sensor mat. To pair new receiver, you should follow the steps
below :
UGEnACPSA200
“This device complies with Industry Canadas license-
exempt RSSs. Operation is subject to the following two
conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including
interference that may cause undesired operation of the
device.”
FCC CLASS B
NOTE: This equipment has been tested and found
to comply with the limits for a Class B digital device,
pursuant to Part 15 of FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning the equipment o󰀨 and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Re-orient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit di󰀨erent from that
to which the receiver is connected.
• Consult the dealer or an experienced radio TV technician for help.
NOTICE: This This class B digital apparatus complies with Canadian
ICES-003. This product meets the applicable Industry Canada
technical specications.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this devise must
accept any interference received, including interference
that may cause undesired operation.


Specyfikacje produktu

Marka: Geemarc
Kategoria: Niesklasyfikowane
Model: AMPLICALL PSA200

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Geemarc AMPLICALL PSA200, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Geemarc

Geemarc

Geemarc AMPLICALL 110 Instrukcja

4 Października 2024
Geemarc

Geemarc AMPLICALL 150 Instrukcja

4 Października 2024
Geemarc

Geemarc AMPLICALL 6-LR Instrukcja

4 Października 2024
Geemarc

Geemarc AMPLICALL 140 Instrukcja

4 Października 2024
Geemarc

Geemarc AMPLICALL 101 Instrukcja

4 Października 2024
Geemarc

Geemarc CL7100 Instrukcja

20 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024