Instrukcja obsługi Gardena 1775


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Gardena 1775 (13 stron) w kategorii Inne narzędzia ogrodowe. Ta instrukcja była pomocna dla 12 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/13
D
DBetriebsanleitung
Hauswasserwerk
GB Operating Instructions
Pressure Tank Unit
FMode d’emploi
Groupe de surpression
NL Instructies voor gebruik
Hydrofoorpomp
SBruksanvisning
Hydroforpump
IIstruzioni per l’uso
Autoclave
EManual de uso
Estación de Bombeo con Calderín
PInstruções de utilização
Bomba doméstica
DK Brugsanvisning
Husvandværk
3000/4 Art. 1770
4000/5 Art. 1772
5000/5 Art. 1774
5000/5 Inox Art. 1775
D
GB
F
NL
SI
EPDK
1770-20.07_Hauswasserwerk 30.05.2007 11:06 Uhr Seite 1
11
GB
Translation of the original operating instructions from German.
Please read these operating instructions carefully and observe
the notes given. Use these operating instructions to familiarise
yourself with the Pressure Tank Unit, its proper use and the safety
instructions.
For safety reasons, children and young people under 16 years of
age as well as people who are not familiar with these operating
instructions should not use this Pressure Tank Unit.
Please keep these operating instructions in a safe place.
Contents: 1. Where to use your GARDENA Pressure Tank Unit. . . . . . . . 11
2. Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3. Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5. Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
8. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
9. Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
10. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1. Where to use your GARDENA Pressure Tank Unit
Correct use: The GARDENA Pressure Tank Unit is intended for private use in
the house and garden; it is not intended for operation of watering
equipment and accessories in public gardens.
Open consumers (e.g. taps) can cause fluctuations in pressure at
certain rates of flow around opening and closing.
Liquids pumped: The GARDENA Pressure Tank Unit can be used to deliver rain-
water, tap water and chlorinated swimming pool water.
Please note:
The GARDENA Pressure Tank Unit is not suitable for continuous
operation (e.g. industrial use, continuous circulation operations).
Corrosive, easily combustible, aggressive or explosive liquids
(such as gasoline, petroleum or nitro thinner), saltwater and
food must not be pumped. The temperature of the liquid
must not exceed 35 °C.
GARDENA Pressure Tank Unit
3000/4, 4000/5, 5000/5, 5000/5 Inox
Welcome to the Garden of GARDENA ...
12
GB
Electrical safety:
DANGER ! Electric shock !
Risk of injury due to electric
shock !
Always unplug your Garden Pressure
Tank Unit before
filling, after operation,
when troubleshooting and before
carrying out any maintenance work.
Caution: Pursuant to DIN VDE 0100-702 use of
the pump near to swimming pools and garden
ponds and other similar places is only
permissible if the pump is operated via a
residual-current device (FI switch) with a
residual current rating of 30 mA.
The pump must be located on solid, even
ground, protected from flooding. Take care that
the pump cannot fall into water.
As an additional safety device an authorised
safety switch can be used.
Please ask your electrician for his advice.
Data indicated on the type plate must match
the technical data of the mains supply.
Pursuant to DIN VDE 0620 the power cable as
well as any extension cable must not have a
smaller diameter than rubber sheathed cables
described with letter symbols H07 RNF.
Protect the power cable from heat, oil and
sharp edges.
Do not use the power cable for carrying the
pump or for unplugging.
In Austria
In Austria the electrical connection must satisfy
the ÖVE-EM 42, T2 (2000)/1979 § 22 to §
2022.1. This requires that pumps used for
swimming pools and garden ponds may only
be powered through an isolating transformer.
Please ask your electrician for his advice.
In Switzerland
In Switzerland portable devices that are used
outdoors must be connected through an earth
leakage circuit breaker. Mobile appliances that
are used outdoors must be connected via a
residual-current device.
2. Safety instructions
General Information:
Risk of injury due to hot water !
If the pressure switch is defective and the
pressure tank unit runs for an extended
period (> 5 min) when the pressure side
outlets are closed, the water in the pressure
tank unit can become heated so that hot
water can emerge from the outlet and
cause injuries.
Pump may only run for max. 5 min with
the discharge side closed.
If the water supply on the intake side of the
pump fails, the water in the pump can heat
up so that if water emerges, injuries could
be caused by the hot water.
Disconnect pump from the mains, allow
water to cool down and ensure the water
supply is functioning correctly before
starting the pump again.
Before operating the pressure tank unit, first
make a visual check to ensure there is no
damage to the
pressure tank unit (especially
regarding power cable and plug).
A damaged pressure tank unit must not be used.
In case of damage, please have the pressure
tank unit checked by our GARDENA Service
Centre or by an authorised electrician.
Protect the pump from rain. Do not use the
pressure tank unit in a wet or moist area.
In order to avoid dry-running of the pressure
tank unit, take care that the end of the suction
hose is always submerged into the liquid.
The pressure tank unit must not be run dry nor
with the stopcock in the suction pipework clo-
sed.
Before each operation, fill the pressure tank
unit to overflowing with approx. 2 to 3 l of
the liquid to be pumped!
Sand and other abrasive substances in the
liquid cause increased wear and reduce the
pump’s output.
When using the pump for domestic water
supply, please adhere to the local water and
sewerage regulations. In addition observe the
regulations of DIN 1988.
If necessary contact your local water
authority.


Specyfikacje produktu

Marka: Gardena
Kategoria: Inne narzędzia ogrodowe
Model: 1775

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Gardena 1775, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Inne narzędzia ogrodowe Gardena

Instrukcje Inne narzędzia ogrodowe

Najnowsze instrukcje dla Inne narzędzia ogrodowe