CARE OF YOUR FUJITSU HARD DISK DRIVE (HDD)
Careful handling and installation of your HDD is paramount to the longevity of the unit. The internal mechanism of the HDD can be
seriously damaged if the HDD is subjected to forces outside the environmental specifications. When transporting the HDD, always use the
original packaging in which the HDD was delivered to you, and avoid exposing the HDD to extreme changes in temperature to minimize the
risk of condensation.
Handling
1. Never drop the unit. Handle it with care.
2. Never move the HDD while the disks are spinning. Note that the disks spin when the HDD is powered on and also immediately after
power off. Refer to the Start/Stop specification for your HDD.
3. Always turn off the power before connecting or disconnecting the interface cable. The same applies to changing any of the switches or
terminal settings except Write protect switch on NP model drives.
4. Never place the HDD in the vicinity of equipment giving off strong magnetic fields, such as CRT monitors, televisions, or loudspeakers.
5. Never use any cleaning agents or liquids on the HDD.
6. Always use an antistatic mat and wrist strap when handling the HDD. Hold the HDD by the base casting and never touch the components
on printed circuit board assembly.
7. Never remove any labels from the HDD or deface them in any way.
8. Never open the HDD for any reason. Doing so will void any warranties.
9. Always pay close attention to the mounting specifications such as those for sway space and cooling. If the temperature difference
between the storage location and installation locations exceeds 10°C, for temperature acclimation purposes, leave the HDD in the new
location for at least two hours before turning it on. This minimizes any risk of condensation forming on the HDD.
The HDD needs NO preventative or periodic maintenance during its service life if properly used in the appropriate environment.
INSTALLATION
1. ORIENTATION–The HDD can be installed flat on any of its six sides. Inclination from vertical or horizontal plane should not exceed
5°.
2. MOUNTING SCREW INSTALLATION–When the mounting screw holes on the side of the HDD are used, be sure to use the two pairs
of outer holes. Do not use the center hole in conjunction with only one of the outer holes. The screws must not penetrate the HDD by more
than 5.0 millimeters. Impact caused by the electric screwdriver must be within the HDD specifications.
3. COOLING–Allow space above and below the HDD to provide an adequate air flow. Fan cooling is recommended. The HDD
temperature measured at center of top cover (label side) should never exceed 60°C. See Table 1.
Table 1. Reference value of airflow
Environmental temperature Required velocity of airflow
30°C > 0.3m/s
35°C > 0.6 m/s
40°C > 0.9 m/s
45°C > 1.5 m/s
4. TERMINATIONA terminator should be installed externally at both ends of the SCSI bus.
5. TERMINATOR POWERTerminator power must be supplied to terminator for correct operation. This can be supplied from either the
HDD, except for NC model or the SCSI bus. If only NC models are connected to the SCCI bus, terminator power should be supplied
externally.
6. CONNECTING–To avoid potential damage to the HDD, make sure that connector type and orientation is correct.
CAUTION: Your warranty may be voided if the connector is damaged as a result of incorrect insertion.
MBA3300NC, MBA3300NP, MBA3147NC, MBA3147NP,
MBA3073NC, MBA3073NP
HARD DISK DRIVES INSTALLATION GUIDE
FUJITSU LIMITED
Storage Products Group
4-1-1 Kamikodanaka, Nakahara-ku, Kawasaki 211-8588, Kanagawa-ken, Japan
Copyright © 2007 FUJITSU LIMITED
C141-E271-01EN
http://www.fujitsu.com/
Undermentioned information is effective only in EU for traceability of the EMC Directive
Manufacturer:
Fujitsu Limited
4-1-1 Kamikodanaka, Nakahara-ku, Kawasaki 211-8588, Kanagawa-ken, Japan
Authorized representative importer / distributor in EU:
Fujitsu Europe Limited
Ha
y
es Park Central, Ha
y
es End Road, Ha
y
es, Middlesex, UB4 8FE, United Kin
g
dom
Diagram and user-selectable options (on NP models only)
Below is a diagram of the main board of SCSI HDD and also a summary of the user-selectable options including guidelines for installation
of the HDD.
This setting applies only for NP models.
Figure 1. Option select terminal
Table 2. CN2 Terminal Setting (on NP models only)
Pin # Setting Item Function
1-2 SCSI ID 0 See Table 3.
3-4 SCSI ID 1
5-6 SCSI ID 2
7-8 SCSI ID 3
9-10 Write protect Open ……Write operation is enabled. (default)
Short ……Write operation is disabled.
11-12 Motor start mode Open ……Starting of motor is controlled with START/STOP
UNIT command.
Short ……Motor is started immediately after power supply is
turned on or microcode is downloaded.
(default)
13-14 Force Narrow Open ……16-bit bus mode (default)
Short ……Pull upper 8bits and parity internally when HDD is
connected to Narrow SCSI bus.
15-16 Force Single Ended Open ……Follows DIFFSNS signal level on SCSI bus. (default)
Short ……Single-Ended mode
17 GND
18, 19 N.C
20 IDD Reset Input signal
21-22 Remote LED Output signal
23-24 Terminal power supply Open ……HDD does not supply terminator power to SCSI bus.
Short ……HDD supplies terminator power to SCSI bus. (default)
Table 3. SCSI ID Setting on CN2 (on NP models only)
Pin 1-2 Pin 3-4 Pin 5-6 Pin 7-8 ID Pin 1-2 Pin 3-4 Pin 5-6 Pin 7-8 ID
Open Open Open Open 0 Open Open Open Short 8
Short Open Open Open 1 Short Open Open Short 9
Open Short Open Open 2 Open Short Open Short 10
Short Short Open Open 3 Short Short Open Short 11
Open Open Short Open 4 Open Open Short Short 12
Short Open Short Open 5 Short Open Short Short 13
Open Short Short Open 6 Open Short Short Short 14
Short Short Short Open 7 Short Short Short Short 15 (default)
Pin 1
CN2
Pin 2
Pin 23 Pin 24


Specyfikacje produktu

Marka: Fujitsu
Kategoria: dysk twardy
Model: MBA3300NP
Wysokość produktu: 25.4 mm
Szerokość produktu: 101.6 mm
Głębokość produktu: 146 mm
Waga produktu: 750 g
Napięcie pracy: 5 / 12 V
Wewnętrzny: Tak
Zakres temperatur (eksploatacja): 5 - 55 °C
Zakres wilgotności względnej: 5 - 95 %
Pobór mocy: 12.8 W
Zakres temperatur (przechowywanie): -40 - 70 °C
Dopuszczalna wilgotność względna: 5 - 95 %
Standardowe rozwiązania komunikacyjne: SATA
Wymiary produktu (SxGxW): 101.6 x 143 x 25.4 mm
Dopuszczalna wysokość podczas eksploatacji (n.p.m.): 0 - 3000 m
MTBF (Średni okres międzyawaryjny): 1400000 h
Pojemność HDD: 300 GB
Szybkość HDD: 15000 RPM
Rozmiar HDD: 3.5 "
Rozmiar bufora dysku pamięci: 16 MB
Dopuszczalna wysokość (n.p.m.): 0 - 12000 m
Wstrząsy podczas pracy: 65 G
Średnie opóźnienie: 2.00 ms
Czas wyszukiwania między ścieżkami: 0.2 ms
Pełne wyszukiwanie seek time: 8 ms
Średni czas poszukiwania: 3.4 ms
Wstrząsy podczas przechowywania: 250 G
Wibracje podczas pracy: 0.6mm (5 - 20 Hz)/ 1.0G (20 - 300 Hz) G
Wibracje podczas przechowywania: 3.1mm (5 - 20 Hz)/ 5.0G (20 - 300Hz) G