Instrukcja obsługi Fujitsu ARTA36LATU

Fujitsu klimatyzacja ARTA36LATU

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Fujitsu ARTA36LATU (16 stron) w kategorii klimatyzacja. Ta instrukcja była pomocna dla 12 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/16
OPERATING MANUAL
P/N9374379187
KEEP THIS MANUAL
FOR FUTURE REFERENCE
AIR CONDITIONER
DUCT TYPE
ART Series
FUJITSU GENERAL LIMITED
9374379187.indd 1
9374379187.indd 1
9374379187.indd 1
9374379187.indd 19374379187.indd 1 9/26/07 5:11:08 PM
9/26/07 5:11:08 PM
9/26/07 5:11:08 PM
9/26/07 5:11:08 PM9/26/07 5:11:08 PM
1
CONTENTS
SAFETY PRECAUTIONS ........................................ 1
NAME OF PARTS .................................................. 2
PREPARATORY OPERATION ................................. 3
OPERATION ........................................................... 4
TIMER FUNCTIONS ............................................... 6
ON/OFF TIMER ....................................................... 6
WEEKLY TIMER ...................................................... 7
SAFETY PRECAUTIONS
l Do not attempt to install this air conditioner by yourself.
l This unit contains no user-serviceable parts. Always consult authorized service person-
nel for repairs.
l When moving, consult authorized service personnel for disconnection and installation
of the unit.
l Do not become over-exposed to cold air by staying in the direct path of the airfl ow of
the air conditioner for extended periods of time.
l Do not insert fi ngers or objects into the outlet port or intake grilles.
l Do not start and stop air conditioner operation by turning off the electrical breaker and
so on.
l In the event of a malfunction (burning smell, etc.), immediately stop operation, turn
off the electrical breaker, and consult authorized service personnel.
l Provide occasional ventilation during use.
l Do not direct air fl ow at fi replaces or heating apparatus.
l Do not climb on, or place objects on, the air conditioner.
l Do not hang objects from the indoor unit.
l Do not set fl ower vases or water containers on top of air conditioners.
l Do not expose the air conditioner directly to water.
l Do not operate the air conditioner with wet hands.
l Do not touch the switches with sharp objects.
l Turn off power source when not using the unit for extended periods.
l Always turn off the electrical breaker whenever cleaning the air conditioner or chang-
ing the air fi lter.
l Connection valves become hot during Heating; handle with care.
l Check the condition of the installation stand for damage.
l Do not place animals or plants in the direct path of the air fl ow.
l When restarting after a long period of disuse in the winter, turn the power switch on
at least 12 hours before starting the unit.
l Do not drink the water drained from the air conditioner.
l Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
l Do not apply any heavy pressure to radiator fi ns.
l Operate only with air fi lters installed.
l Do not block or cover the intake grille and outlet port.
l Ensure that any electronic equipment is at least one metre away from either the indoor
or outdoor units.
l Avoid installing the air conditioner near a fi replace or other heating apparatus.
l When installing the indoor and outdoor units, take precautions to prevent access by
infants.
l Do not use infl ammable gases near the air conditioner.
lBefore using the appliance, read these “SAFETY PRECAUTIONS” thoroughly and operate in the correct way.
l The instructions in this section all relate to safety; be sure to maintain safe operating conditions.
l “DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
TEMPERATURE SET BACK TIMER ....................... 9
CLEANING AND CARE ........................................ 10
TROUBLESHOOTING .......................................... 10
OPERATING TIPS ................................................. 12
SELF-DIAGNOSIS ................................................ 14
TEMPERATURE AND HUMIDITY RANGE ............. 14
DANGER! This mark indicates procedures which, if improperly performed, are most likely to
result in the death of or serious injury to the user or service personnel.
WARNING! This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user.
CAUTION! This mark indicates procedures which, if improperly performed, might possibly result
in personal harm to the user, or damage to property.
DANGER!
CAUTION!
9374379187.indd Sec1:1
9374379187.indd Sec1:1
9374379187.indd Sec1:1
9374379187.indd Sec1:19374379187.indd Sec1:1 9/26/07 5:11:10 PM
9/26/07 5:11:10 PM
9/26/07 5:11:10 PM
9/26/07 5:11:10 PM9/26/07 5:11:10 PM
2
NAME OF PARTS
Remote controller
1 Start/Stop Button
2 Set Temperature Button
3 Master Control Button
4 Fan Control Button
5 Economy Button
6 Timer Mode (CLOCK ADJUST)
Button
7 DAY (DAY OFF) Button
8 SET BACK Button
9 Set Time Button
! DELETE Button
" SET Button
# Vertical Air ow Direction and
Swing Button*1
$ Horizontal Airfl ow Direction and
Swing Button*2
% Filter Button*3
& Operation Lamp
( Timer and Clock Display
) Operation Mode Display
~ Fan Speed Display
+ Operation Lock Display
, Temperature Display
- Function Display
Defrost Display
Thermo Sensor Display
Economy Display
Vertical Swing Display*4
Horizontal Swing Display*5
Filter Display*6
*1~6 These functions cannot be used.
I
H
G
J
K
E
1
C
5
D
A
0
3
4
B
8
6
2
F
9
7
9374379187.indd Sec1:2
9374379187.indd Sec1:2
9374379187.indd Sec1:2
9374379187.indd Sec1:29374379187.indd Sec1:2 9/26/07 5:11:10 PM
9/26/07 5:11:10 PM
9/26/07 5:11:10 PM
9/26/07 5:11:10 PM9/26/07 5:11:10 PM


Specyfikacje produktu

Marka: Fujitsu
Kategoria: klimatyzacja
Model: ARTA36LATU
Kolor produktu: Stal nierdzewna
Rodzaj żarówki: LED
Materiał obudowy: Stal nierdzewna
Typ kontroli: Przyciski
Wbudowany wyświetlacz: Nie
Częstotliwość wejściowa AC: 50/60 Hz
Napięcie wejściowe AC: 220 - 240 V
Szerokość produktu: 900 mm
Głębokość produktu: 480 mm
Waga produktu: 8550 g
Szerokość opakowania: 950 mm
Wysokość opakowania: 540 mm
Głębokość opakowania: 245 mm
Poziom hałasu: 62 dB
Klasa wydajności energetycznej: C
Skala efektywności energetycznej: A +++ do D
Waga wraz z opakowaniem: 10500 g
Oświetlenie: 262 lx
Model: Naścienny
Roczne zużycie energii: 37 kWh
Prędkości: 3
Maksymalna moc ekstrakcji: 305 m³/h
Rodzaj ekstrakcji: Kanałowe / obiegowe
Klasa wydajności przepływu dynamicznego: E
Klasa wydajności świecenia: A
Klasa skuteczności filtra przeciwtłuszczowego: C
Rodzaj filtra tłuszczu: Metal
Zdjemowalny filtr: Tak
Silnik dołączony: Tak
Ilość silników: 1
Prędkość w trybie intensywnym: Nie
Średnica przyłącza odprowadzającego dym: 150 mm
Ciśnienie (Pa): 115

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Fujitsu ARTA36LATU, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje klimatyzacja Fujitsu

Instrukcje klimatyzacja

Najnowsze instrukcje dla klimatyzacja