Instrukcja obsługi Fujitsu AOYG36LBTB
Fujitsu
klimatyzacja
AOYG36LBTB
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Fujitsu AOYG36LBTB (20 stron) w kategorii klimatyzacja. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/20
INSTALLATION MANUAL
OUTDOOR UNIT
For authorized service personnel only.
INSTALLATIONSANLEITUNG
AUSSENGERÄT
Nur für autorisiertes Fachpersonal.
MANUEL D’INSTALLATION
APPAREIL EXTÉRIEUR
Pour le personnel d’entretien autorisé uniquement.
MANUAL DE INSTALACIÓN
UNIDAD EXTERIOR
Únicamente para personal de servicio autorizado.
MANUALE DI INSTALLAZIONE
UNITÀ ESTERNA
A uso esclusivo del personale tecnico autorizzato.
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
ΕΞΩΤΕΡΙΚΗ ΜΟΝΑΔΑ
Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό .
MANUAL DE INSTALAÇÃO
UNIDADE EXTERIOR
Apenas para pessoal de assistência autorizado.
РУКОВОДСТВО ПО УСТАНОВКЕ
ВНЕШНИЙ МОДУЛЬ
Только для авторизованного обслуживающего персонала .
MONTAJ KILAVUZU
DI ÜN TEŞ İ
Yaln zca yetkili servis personeli için.ı
AIR CONDITIONER
Português E vIk Italiano Español Français Deutsch Englishλλη ά
Русский
Türkçe
PART No. 9379069755-02
[Original instructions]
En-2
WARNING
Do not use this equipment with air or any other unspecifi ed refrigerant in the refrigerant
lines.
Excess pressure can cause a rupture.
During installation, make sure that the refrigerant pipe is attached fi rmly before you run
the compressor.
Do not operate the compressor under the condition of refrigerant piping not attached
properly with 2-way or 3-way valve open. This may cause abnormal pressure in the
refrigeration cycle that leads to rupture and even injury.
When installing and relocating the air conditioner, do not mix gases other than the
specifi ed refrigerant (R410A) to enter the refrigerant cycle.
If air or other gas enters the refrigerant cycle, the pressure inside the cycle will rise to
an abnormally high value and cause rupture, injury, etc.
To connect the indoor unit and outdoor unit, use air conditioner piping and cables
available locally as standard parts. This manual describes proper connections using
such installation set.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualifi ed persons in order to avoid a hazard.
Do not modify power cable, use extension cable or branch wiring. Improper use may
cause electric shock or fi re by poor connection, insuffi cient insulation or over current.
Do not purge the air with refrigerants but use a vacuum pump to vacuum the installation.
There is not extra refrigerant in the outdoor unit for air purging.
Use a vacuum pump for R410A exclusively.
Using the same vacuum pump for different refrigerants may damage the vacuum pump
or the unit.
Use a clean gauge manifold, vacuum pump and charging hose for R410A exclusively.
During the pump-down operation, make sure that the compressor is turned off before
you remove the refrigerant piping.
Do not remove the connection pipe while the compressor is in operation with 2 way or
3 way valve open. This may cause abnormal pressure in the refrigeration cycle that
leads to rupture and even injury.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they
do not play with the appliance.
To avoid danger of suffocation, keep the plastic bag or thin fi lm used as the packaging
material away from young children.
CAUTION
Read carefully all safety information written in this manual before you install or use the
air conditioner.
Do not attempt to install the air conditioner or a part of the air conditioner by yourself.
This unit must be installed by qualifi ed personnel with a capacity certifi cate for handling
refrigerant fl uids. Refer to regulation and laws in use on installation place.
Install the product by following local codes and regulations in force at the place of
installation, and the instructions provided by the manufacturer.
This product is part of a set constituting an air conditioner. The product must not be
installed alone or be installed with non-authorized device by the manufacturer.
Always use a separate power supply line protected by a circuit breaker operating on all
wires with a distance between contact of 3 mm for this product.
To protect the persons, earth (ground) the product correctly, and use the power cable
combined with an Earth Leakage Circuit Breaker (ELCB).
This product is not explosion proof, and therefore should not be installed in explosive
atmosphere.
Do not touch the fi ns of the heat exchanger. Touching the heat exchanger fi ns could result
in damage to the fi ns or personal injury such as skin rupture.
This product contains no user-serviceable parts. Always consult experienced service
technicians for repairing.
When moving or relocating the air conditioner, consult experienced service technicians
for disconnection and reinstallation of the product.
Children should be monitored to ensure they do not play with the device.
Do not place any other electrical products or household belongings under indoor unit or
outdoor unit. Dripping condensation from the unit might get them wet, and may cause
damage or malfunction of your property.
2. ABOUT THIS PRODUCT
d
2.1. Precautions for using R410A refrigerant
WARNING
Do not introduce any substance other than the prescribed refrigerant into the
refrigeration cycle. If air enters the refrigeration cycle, the pressure in the refrigeration
cycle will become abnormally high and cause the piping to rupture.
If there is a refrigerant leak, make sure that it does not exceed the concentration limit.
If a refrigerant leak exceeds the concentration limit, it can lead to accidents such as
oxygen starvation.
1. SAFETY PRECAUTIONS
Be sure to read this manual carefully before installation.•
The warnings and precautions indicated in this manual contain important information •
pertaining to your safety. Be sure to observe them.
Hand this manual, together with the operating manual, to the customer. Request the •
customer to keep them on hand for future use, such as for relocating or repairing the
unit.
WARNING This mark indicates procedures which, if improperly performed,
might lead to the death or serious injury of the user.
CAUTION
This mark indicates procedures which, if improperly performed, might
possibly result in personal harm to the user, or damage to property.
WARNING
Installation of this product must be done by experienced service technicians or
professional installers only in accordance with this manual. Installation by nonprofessional
or improper installation of the product may cause serious accidents such as injury, water
leakage, electric shock, or fi re. If the product is installed in disregard of the instructions in
this manual, it will void the manufacturer’s warranty
To avoid getting an electric shock, never touch the electrical components soon after the
power supply has been turned off. After turning off the power, always wait 10 minutes or
more before you touch the electrical components.
Do not turn ON the power until all work has been completed. Turning ON the power
before the work is completed can cause serious accidents such as electric shock or fi re.
If refrigerant leaks while work is being carried out, ventilate the area. If the refrigerant
comes in contact with a fl ame, it produces a toxic gas.
Installation must be performed in accordance with regulations, codes, or standards for
electrical wiring and equipment in each country, region, or the installation place.
INSTALLATION MANUAL
OUTDOOR UNIT
PART No. 9379069755-02 English
Contents
1. SAFETY PRECAUTIONS ............................................................................................ 2
2. ABOUT THIS PRODUCT
2.1. Precautions for using R410A refrigerant ............................................................ 2
2.2. Special tools for R410A ...................................................................................... 3
2.3. Accessories ........................................................................................................3
3. INSTALLATION WORK
3.1. Selecting an installation location ........................................................................3
3.2. Drain installation .................................................................................................4
3.3. Installation dimensions .......................................................................................4
3.4. Transporting the unit .......................................................................................... 5
3.5. Installation .......................................................................................................... 5
4. PIPE SELECTION
4.1. Selecting the pipe material .................................................................................5
4.2. Protection of pipes .............................................................................................6
4.3. Refrigerant pipe size and allowable piping length .............................................. 6
4.4. Connectable pipe diameter and max. piping length ........................................... 6
5. PIPE INSTALLATION-1
5.1. Opening a knock out hole ..................................................................................7
5.2. Brazing ............................................................................................................... 7
5.3. Indoor unit pipe connections ..............................................................................7
5.4. Flare connection (pipe connection) .................................................................... 7
5.5. Sealing test ........................................................................................................8
5.6. Vacuum process ................................................................................................ 8
5.7. Additional charging ............................................................................................. 9
6. ELECTRICAL WIRING
6.1. Notes for electrical wiring ................................................................................. 10
6.2. Selecting circuit breaker and wiring .................................................................11
6.3. Knock out holes for wiring ................................................................................11
6.4. Wiring method .................................................................................................. 11
7. PIPE INSTALLATION-2
7.1. Installing insulation ...........................................................................................12
7.2. Filling with putty ................................................................................................12
8. HOW TO OPERATE DISPLAY UNIT
8.1. Display unit position .........................................................................................12
8.2. Description of display and button ..................................................................... 13
9. FIELD SETTING
9.1. Field setting buttons ......................................................................................... 13
9.2. Function settings ..............................................................................................13
10. EXTERNAL INPUT AND OUTPUT
10.1. External input ................................................................................................... 14
10.2. External output ................................................................................................. 15
11. TEST RUN
11.1. Pre-test run check items ..................................................................................15
11.2. Test operation method ..................................................................................... 16
11.3. Checklist ...........................................................................................................16
12. ERROR CODES
12.1. Error display mode ........................................................................................... 17
12.2. Error code check table ..................................................................................... 17
13. PUMP DOWN
13.1. Preparation for pump down ..............................................................................18
13.2. Pump down procedure ..................................................................................... 18
En-3
Name and shape Q’ty Description
Installation
manual
1
This manual
Drain pipe
1
For outdoor unit drain piping work
(May not be supplied, depending on
the model.)
Drain cap
2
One-touch bush
2
For power supply cable and
connection cable installation
3. INSTALLATION WORK
Make sure to obtain the customer’s approval for selecting and installing the outdoor unit.
3.1. Selecting an installation location
WARNING
Securely install the outdoor unit at a location that can withstand the weight of the unit.
Otherwise, the outdoor unit may fall and cause injury.
Be sure to install the outdoor unit as prescribed, so that it can withstand earthquakes
and typhoons or other strong winds. Improper installation can cause the unit to topple or
fall, or other accidents.
Do not install the outdoor unit near the edge of a balcony. Otherwise, children may climb
onto the outdoor unit and fall off of the balcony.
CAUTION
Do not install the outdoor unit in the following areas:
Area with high salt content, such as at the seaside. It will deteriorate metal parts, •
causing the parts to fail or the unit to leak water.
Area fi lled with mineral oil or containing a large amount of splashed oil or steam, •
such as a kitchen. It will deteriorate plastic parts, causing the parts to fail or the unit
to leak water.
Area that generates substances that adversely affect the equipment, such as sulfuric •
gas, chlorine gas, acid, or alkali. It will cause the copper pipes and brazed joints to
corrode, which can cause refrigerant leakage.
Area containing equipment that generates electromagnetic interference. It will cause •
the control system to malfunction, preventing the unit from operating normally.
Area that can cause combustible gas to leak, contains suspended carbon fi bers or •
fl ammable dust, or volatile infl ammables such as paint thinner or gasoline. If gas
leaks and settles around the unit, it can cause a fi re.
Area where small animals may live. It may cause failure, smoke or fi re if small •
animals enter and touch internal electrical parts.
Area where animals may urinate on the unit or ammonia may be generated. •
Do not tilt the outdoor unit more than 3 degrees.
Install the outdoor unit in a well-ventilated location away from rain or direct sunlight.
If the outdoor unit must be installed in an area within easy reach of the general public,
install as necessary a protective fence or the like to prevent their access.
Install the outdoor unit in a location that would not inconvenience your neighbors, as
they could be affected by the airfl ow coming out from the outlet, noise, or vibration. If it
must be installed in proximity to your neighbors, be sure to obtain their approval.
If the outdoor unit is installed in a cold region that is affected by snow accumulation, snow
fall, or freezing, take appropriate measures to protect it from those elements.
To ensure a stable operation, install inlet and outlet ducts.
Install the outdoor unit in a location that is away from exhaust or the vent ports that
discharge vapor, soot, dust, or debris.
Install the indoor unit, outdoor unit, power supply cable, transmission cable, and remote
control cable at least 1 m away from a television or radio receivers. The purpose of this
is to prevent TV reception interference or radio noise. (Even if they are installed more
than 1 m apart, you could still receive noise under some signal conditions.)
Branch switch and
circuit breaker
1 m or more
1 m or more
Branch switch and
circuit breaker
WARNING
Do not touch refrigerant that has leaked from the refrigerant pipe connections or other
areas. Touching the refrigerant directly can cause frostbite.
If a refrigerant leak occurs during operation, immediately vacate the premises and
thoroughly ventilate the area. If the refrigerant comes in contact with a fl ame, it produces
a toxic gas.
The basic installation work procedures are the same as conventional refrigerant (R22)
models.
However, pay careful attention to the following points:
Since the working pressure is 1.6 times higher than that of conventional refrigerant
(R22) models, some of the piping and installation and service tools are special. (See the
table below.)
Especially, when replacing a conventional refrigerant (R22) model with a new refrigerant
R410A model, always replace the conventional piping and fl are nuts with the R410A piping
and fl are nuts.
Models that use refrigerant R410A have a different charging port thread diameter to pre-
vent erroneous charging with conventional refrigerant (R22) and for safety. Therefore,
check beforehand. [The charging port thread diameter for R410A is 1/2-20 UNF.]
Be more careful that foreign matter (oil, water, etc.) does not enter the piping than with
refrigerant (R22) models. Also, when storing the piping, securely seal the opening by
pinching, taping, etc.
When charging the refrigerant, take into account the slight change in the composition of
the gas and liquid phases. And always charge from the liquid phase where refrigerant
composition is stable.
2.2. Special tools for R410A
WARNING
To install a unit that uses R410A refrigerant, use dedicated tools and piping materials
that have been manufactured specifi cally for R410A use. Because the pressure of
R410A refrigerant is approximately 1.6 times higher than R22, failure to use dedicated
piping material or improper installation can cause rupture or injury. Furthermore, it can
cause serious accidents such as water leakage, electric shock, or fi re.
Tool name Contents of change
Gauge manifold
Pressure is high and cannot be measured with a conventional
(R22) gauge. To prevent erroneous mixing of other refrigerants,
the diameter of each port has been changed.
It is recommended the gauge with seals -0.1 to 5.3 MPa
(-1 to 53 bar) for high pressure.
-0.1 to 3.8 MPa (-1 to 38 bar) for low pressure.
Charge hose To increase pressure resistance, the hose material and base
size were changed.
Vacuum pump A conventional vacuum pump can be used by installing a
vacuum pump adapter.
Gas leakage detector Special gas leakage detector for HFC refrigerant R410A.
Copper pipes
It is necessary to use seamless copper pipes and it is desirable that the amount of residual
oil is less than 40 mg/10 m. Do not use copper pipes having a collapsed, deformed or
discolored portion (especially on the interior surface). Otherwise, the expansion value or
capillary tube may become blocked with contaminants.
As an air conditioner using R410A incurs pressure higher than when using R22, it is
necessary to choose adequate materials.
Thicknesses of copper pipes used with R410A are as shown in the table. Never use copper
pipes thinner than 0.8 mm even when it is available on the market.
Thicknesses of Annealed Copper Pipes (R410A)
Pipe outside diameter [mm (in.)] Thickness [mm]
6.35 (1/4) 0.80
9.52 (3/8) 0.80
12.70 (1/2) 0.80
15.88 (5/8) 1.00
19.05 (3/4) 1.20
2.3. Accessories
WARNING
For installation purposes, be sure to use the parts supplied by the manufacturer or other
prescribed parts. The use of non-prescribed parts can cause serious accidents such as
the unit falling, water leakage, electric shock, or fi re.
Following installation parts are supplied. Use them as required.
Keep this manual in a safe place, and do not discard any other accessories until the
installation work has been completed.
Specyfikacje produktu
Marka: | Fujitsu |
Kategoria: | klimatyzacja |
Model: | AOYG36LBTB |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Fujitsu AOYG36LBTB, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje klimatyzacja Fujitsu
14 Października 2024
12 Października 2024
9 Października 2024
9 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
Instrukcje klimatyzacja
- klimatyzacja Bauknecht
- klimatyzacja Samsung
- klimatyzacja Electrolux
- klimatyzacja DeLonghi
- klimatyzacja AEG
- klimatyzacja Beko
- klimatyzacja LG
- klimatyzacja Gorenje
- klimatyzacja LERAN
- klimatyzacja Sharp
- klimatyzacja TCL
- klimatyzacja Russell Hobbs
- klimatyzacja Livoo
- klimatyzacja Dometic
- klimatyzacja Bosch
- klimatyzacja SHE
- klimatyzacja Candy
- klimatyzacja Whirlpool
- klimatyzacja Ferroli
- klimatyzacja Easy Home
- klimatyzacja Midea
- klimatyzacja Kärcher
- klimatyzacja Hisense
- klimatyzacja Infiniton
- klimatyzacja Panasonic
- klimatyzacja Nedis
- klimatyzacja Be Cool
- klimatyzacja Medion
- klimatyzacja Black & Decker
- klimatyzacja Adler
- klimatyzacja Toshiba
- klimatyzacja Tesla
- klimatyzacja Westinghouse
- klimatyzacja Rinnai
- klimatyzacja Domo
- klimatyzacja GE
- klimatyzacja Ardes
- klimatyzacja Taurus
- klimatyzacja Orbegozo
- klimatyzacja Blaupunkt
- klimatyzacja Vivax
- klimatyzacja Siemens
- klimatyzacja Danby
- klimatyzacja Einhell
- klimatyzacja APC
- klimatyzacja Haier
- klimatyzacja Sigma
- klimatyzacja Jocel
- klimatyzacja Hyundai
- klimatyzacja Bimar
- klimatyzacja Rowenta
- klimatyzacja Mesko
- klimatyzacja Master
- klimatyzacja Honeywell
- klimatyzacja Concept
- klimatyzacja Tripp Lite
- klimatyzacja Truma
- klimatyzacja Ozito
- klimatyzacja Hotpoint
- klimatyzacja Kenwood
- klimatyzacja Friedrich
- klimatyzacja Trisa
- klimatyzacja Ariston Thermo
- klimatyzacja Zelmer
- klimatyzacja Mestic
- klimatyzacja Wilfa
- klimatyzacja BLUEPALM
- klimatyzacja Amana
- klimatyzacja Hotpoint Ariston
- klimatyzacja Furrion
- klimatyzacja Bomann
- klimatyzacja Teesa
- klimatyzacja Emerio
- klimatyzacja Wood's
- klimatyzacja Create
- klimatyzacja InAlto
- klimatyzacja Meireles
- klimatyzacja Melissa
- klimatyzacja Daikin
- klimatyzacja Alaska
- klimatyzacja Stirling
- klimatyzacja MPM
- klimatyzacja OneConcept
- klimatyzacja Philco
- klimatyzacja Corbero
- klimatyzacja Zanussi
- klimatyzacja Ravanson
- klimatyzacja Thermex
- klimatyzacja GoldAir
- klimatyzacja Trotec
- klimatyzacja Thomson
- klimatyzacja Klarstein
- klimatyzacja Manta
- klimatyzacja Vaillant
- klimatyzacja Bavaria
- klimatyzacja Cecotec
- klimatyzacja Waeco
- klimatyzacja Camry
- klimatyzacja NewAir
- klimatyzacja Keystone
- klimatyzacja Qlima
- klimatyzacja HTW
- klimatyzacja Eden
- klimatyzacja GUTFELS
- klimatyzacja TriStar
- klimatyzacja Bartscher
- klimatyzacja Mitsubishi
- klimatyzacja Dimplex
- klimatyzacja Baxi
- klimatyzacja Arçelik
- klimatyzacja Lavorwash
- klimatyzacja Gree
- klimatyzacja DCG
- klimatyzacja Daizuki
- klimatyzacja G3 Ferrari
- klimatyzacja Omega Altise
- klimatyzacja AKAI
- klimatyzacja Sanyo
- klimatyzacja Remko
- klimatyzacja Clatronic
- klimatyzacja Telefunken
- klimatyzacja Oregon Scientific
- klimatyzacja Calor
- klimatyzacja SVAN
- klimatyzacja IFB
- klimatyzacja Carson
- klimatyzacja Innoliving
- klimatyzacja Argoclima
- klimatyzacja Comfee
- klimatyzacja Bonaire
- klimatyzacja Meaco
- klimatyzacja Kenmore
- klimatyzacja VOX
- klimatyzacja Insignia
- klimatyzacja Element
- klimatyzacja Orima
- klimatyzacja Aspes
- klimatyzacja Hitachi
- klimatyzacja Emerson
- klimatyzacja SereneLife
- klimatyzacja Frigidaire
- klimatyzacja EcoFlow
- klimatyzacja RCA
- klimatyzacja Climadiff
- klimatyzacja Whynter
- klimatyzacja Ridgid
- klimatyzacja Lanaform
- klimatyzacja Electroline
- klimatyzacja Kelvinator
- klimatyzacja Sencor
- klimatyzacja Mistral
- klimatyzacja Nabo
- klimatyzacja Fuave
- klimatyzacja Kalorik
- klimatyzacja Avidsen
- klimatyzacja Suntec
- klimatyzacja Be Quiet!
- klimatyzacja Carrier
- klimatyzacja Geist
- klimatyzacja Esatto
- klimatyzacja Daewoo
- klimatyzacja Livington
- klimatyzacja Consul
- klimatyzacja Kunft
- klimatyzacja Zibro
- klimatyzacja Becken
- klimatyzacja Guzzanti
- klimatyzacja KuulAire
- klimatyzacja Alpatec
- klimatyzacja Volteno
- klimatyzacja ActronAir
- klimatyzacja Tectro
- klimatyzacja Eurom
- klimatyzacja Sauber
- klimatyzacja PRIME3
- klimatyzacja Proline
- klimatyzacja Toyotomi
- klimatyzacja Soler & Palau
- klimatyzacja Monzana
- klimatyzacja Finlux
- klimatyzacja Profile
- klimatyzacja Amcor
- klimatyzacja Argo
- klimatyzacja Anslut
- klimatyzacja Coolix
- klimatyzacja Tosot
- klimatyzacja Korona
- klimatyzacja Progress
- klimatyzacja Vestel
- klimatyzacja Itho
- klimatyzacja Mabe
- klimatyzacja Heinner
- klimatyzacja Termozeta
- klimatyzacja Eldom
- klimatyzacja Jocca
- klimatyzacja Defy
- klimatyzacja White Knight
- klimatyzacja Evolar
- klimatyzacja Kubo
- klimatyzacja Elba
- klimatyzacja Royal Sovereign
- klimatyzacja Ansonic
- klimatyzacja Malmbergs
- klimatyzacja Everglades
- klimatyzacja Heylo
- klimatyzacja ElectriQ
- klimatyzacja Listo
- klimatyzacja Daitsu
- klimatyzacja Ufesa
- klimatyzacja Milectric
- klimatyzacja Olimpia Splendid
- klimatyzacja Saunier Duval
- klimatyzacja Duux
- klimatyzacja Godrej
- klimatyzacja Maiko
- klimatyzacja Essentiel B
- klimatyzacja Team
- klimatyzacja Equation
- klimatyzacja Edy
- klimatyzacja Edgestar
- klimatyzacja Maxicool
- klimatyzacja Dantherm
- klimatyzacja Carrefour Home
- klimatyzacja Equator
- klimatyzacja HQ
- klimatyzacja BOSFOR
- klimatyzacja MundoClima
- klimatyzacja Proklima
- klimatyzacja Home Electric
- klimatyzacja Eco-De
- klimatyzacja Fairland
- klimatyzacja Aconatic
- klimatyzacja Duracraft
- klimatyzacja DEXP
- klimatyzacja Just Fire
- klimatyzacja Teco
- klimatyzacja Khind
- klimatyzacja Chigo
- klimatyzacja Hokkaido
- klimatyzacja Tarrington House
- klimatyzacja Evapolar
- klimatyzacja Orava
- klimatyzacja Fronius
- klimatyzacja SMC
- klimatyzacja D-Let
- klimatyzacja Kogan
- klimatyzacja Braemar
- klimatyzacja Klimaire
- klimatyzacja SEEGER
- klimatyzacja General Electric
- klimatyzacja SPT
- klimatyzacja Simplicity
- klimatyzacja Starlyf
- klimatyzacja Aerian
- klimatyzacja Moa
- klimatyzacja Fuji Electric
- klimatyzacja Polocool
- klimatyzacja Convair
- klimatyzacja Kibernetik
- klimatyzacja Fral
- klimatyzacja Companion
- klimatyzacja Prem-i-air
- klimatyzacja Arcoaire
- klimatyzacja Céliera
- klimatyzacja Bodin
- klimatyzacja AFINTEK
- klimatyzacja Brivis
- klimatyzacja MRCOOL
- klimatyzacja B-Air
- klimatyzacja Trilec
- klimatyzacja Kaden
- klimatyzacja Avallon
- klimatyzacja TURBRO
- klimatyzacja House & Luft
- klimatyzacja Evapcool
- klimatyzacja Protector
- klimatyzacja Vostok
- klimatyzacja American Comfort
- klimatyzacja Ocean Breeze
- klimatyzacja Quirky
- klimatyzacja Krone
- klimatyzacja KwiKool
- klimatyzacja Big Ass Fans
- klimatyzacja Arctic King
- klimatyzacja Artrom
- klimatyzacja Senville
- klimatyzacja Climachill
- klimatyzacja Commercial Cool
- klimatyzacja Riffel
- klimatyzacja Heat Controller
- klimatyzacja Luma Comfort
- klimatyzacja Norpole
- klimatyzacja Kaco
- klimatyzacja Goodwe
- klimatyzacja Swegon
- klimatyzacja JHS
- klimatyzacja FREONIC
- klimatyzacja ARCTIC WIND
- klimatyzacja VänEE
- klimatyzacja Mayer
- klimatyzacja Perfect Aire
- klimatyzacja Koldfront
Najnowsze instrukcje dla klimatyzacja
15 Października 2024
15 Października 2024
15 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024
14 Października 2024