Instrukcja obsługi Fujitsu ABTA45LAT

Fujitsu klimatyzacja ABTA45LAT

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Fujitsu ABTA45LAT (16 stron) w kategorii klimatyzacja. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/16
OPERATING MANUAL
P/N9374379279
KEEP THIS MANUAL
FOR FUTURE REFERENCE
FUJITSU GENERAL LIMITED
AIR CONDITIONER
CEILING SUSPENSION
TYPE
ABT Series
1
CONTENTS
SAFETY PRECAUTIONS ....................................... 1
FEATURES AND FUNCTIONS .............................. 2
NAME OF PARTS ................................................... 2
PREPARATION ....................................................... 4
OPERATION ........................................................... 5
TIMER OPERATION ............................................... 7
SLEEP TIMER OPERATION ................................... 8
FILTER LAMP RESET ............................................. 8
MANUAL AUTO OPERATION ............................... 8
ADJUSTING THE DIRECTION OF
AIR CIRCULATION ................................................. 9
SWING OPERATION ............................................ 10
ECONOMY OPERATION ...................................... 10
CLEANING AND CARE ........................................ 11
SELECTING THE REMOTE CONTROL UNIT
SIGNAL CODE ..................................................... 12
TROUBLESHOOTING .......................................... 12
OPERATING TIPS................................................. 14
TEMPERATURE AND HUMIDITY RANGE .......... 15
DANGER!
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.
When moving, consult authorized service personnel for disconnection and installa-
tion of the unit.
Do not become over-exposed to cold air by staying in the direct path of the airflow of
the air conditioner for extended periods of time.
Do not insert fingers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by turning off the electrical breaker
and so on.
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn
off the electrical breaker, and consult authorized service personnel.
Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set flower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Turn off power source when not using the unit for extended periods.
Always turn off the electrical breaker whenever cleaning the air conditioner or chang-
ing the air filter.
Connection valves become hot during Heating; handle with care.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
When restarting after a long period of disuse in the winter, turn the power switch on
at least 12 hours before starting the unit.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
Avoid installing the air conditioner near a fireplace or other heating apparatus.
Whe
n installing the indoor and outdoor units, take precautions to prevent access by infan
ts.
Do not use inflammable gases near the air conditioner.
CAUTION!
SAFETY PRECAUTIONS
Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
The instructions in this section all relate to safety; be sure to maintain safe operating conditions.
“DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
WARNING!
CAUTION!
This mark indicates procedures which, if improperly performed, are most likely to
result in the death of or serious injury to the user or service personnel.
This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user.
This mark indicates procedures which, if improperly performed, might possibly result
in personal harm to the user, or damage to property.
DANGER!
2
FEATURES AND FUNCTIONS
AUTOMATIC OPERATION
COOLING MODEL
Merely press the START/STOP button, and the unit will
begin automatic operation in the Cooling or Dry mode as
appropriate, in accordance with the thermostat setting
and the actual temperature of the room.
HEAT & COOL MODEL (REVERSE CYCLE)
Merely press the START/STOP button, and the unit will
begin automatic operation in either the Heating, Cooling
or Monitor modes as appropriate, in accordance with the
thermostat setting and the actual temperature of the room.
SLEEP TIMER
COOLING MODEL
When the SLEEP timer button is pressed during Cooling
or Dry mode, the thermostat setting is gradually raised
during the period of operation. When the set time is
reached, the unit automatically turns off.
HEAT & COOL MODEL (REVERSE CYCLE)
When the SLEEP timer button is pressed during Heating
mode, the air conditioner’s thermostat setting is gradu-
ally lowered during the period of operation; during Cool-
ing or Dry mode, the thermostat setting is gradually raised
during the period of operation. When the set time is
reached, the unit automatically turns off.
WIRELESS REMOTE CONTROL UNIT
The WIRELESS REMOTE CONTROL UNIT allows convenient
control of air conditioner operation.
OMNI-DIRECTIONAL AIR FLOW
(SWING OPERATION)
Three-dimensional control over air direction swing is possi-
ble through dual use of both an UP/DOWN air direction swing
and RIGHT/LEFT air direction swing. Since UP/DOWN air
direction flaps operate automatically according to the ope-
rating mode of the unit, it is possible to set air direction based
on the operating mode.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth,
thus allowing cleaner use and easier care.
NAME OF PARTS
Indoor Unit
1 Operating Control Panel
2 MANUAL AUTO button
3 Remote Control Signal Receiver
4 OPERATION Indicator Lamp (green)
5 TIMER Indicator Lamp (orange)
6 FILTER Lamp (red)
If the TIMER indicator lamp flashes when
the timer is operating, it indicates that a
fault has occurred with the timer setting
(see page 15 AUTO Restart).
7 Intake Grille
8 UP/DOWN Air Direction Flaps
9 RIGHT/LEFT Air Direction Louvers
(behind UP/DOWN Air Direction Flaps)
3 2
1
9
8
7
456


Specyfikacje produktu

Marka: Fujitsu
Kategoria: klimatyzacja
Model: ABTA45LAT

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Fujitsu ABTA45LAT, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje klimatyzacja Fujitsu

Fujitsu

Fujitsu AOHG36LATT Instrukcja

12 Października 2024
Fujitsu

Fujitsu ASTG22KMTC Instrukcja

9 Października 2024
Fujitsu

Fujitsu AOEG36KBTB Instrukcja

8 Października 2024
Fujitsu

Fujitsu AOEG45KBTB Instrukcja

8 Października 2024
Fujitsu

Fujitsu AOEG54KBTB Instrukcja

8 Października 2024
Fujitsu

Fujitsu AOEG54KRTA Instrukcja

8 Października 2024
Fujitsu

Fujitsu AOEG45KRTA Instrukcja

8 Października 2024
Fujitsu

Fujitsu AOEG14KBCA2 Instrukcja

8 Października 2024

Instrukcje klimatyzacja

Najnowsze instrukcje dla klimatyzacja

LG

LG HS-H076QPA0 Instrukcja

15 Października 2024
Klarstein

Klarstein Vita Pure 2G Instrukcja

15 Października 2024
Gree

Gree ETAC-15HP265V20B Instrukcja

15 Października 2024
Qlima

Qlima P 126 Instrukcja

14 Października 2024
Mitsubishi

Mitsubishi MSZ-CB22VA Instrukcja

14 Października 2024
Suntec

Suntec Motion 90+ Instrukcja

14 Października 2024
Danby

Danby DTAC120B1WDB Instrukcja

14 Października 2024
Amana

Amana PTC093K35AXXX Instrukcja

14 Października 2024
Amana

Amana AMAP121AB-2 Instrukcja

14 Października 2024
Amana

Amana PTC173J35AXXX Instrukcja

14 Października 2024