Instrukcja obsługi Frico CLIMOB09


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Frico CLIMOB09 (14 stron) w kategorii Klimatyzator - Chłodnica powietrza. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/14
Climobile
.... 2
EN .... 11
SE
Original instructions
.... 20
DE
Climobile
2
EN
General Instructions
Read these instructions carefully prior to
installation and use. Keep this manual for
future reference.
The product may only be used as set out in
the assembly and operating instructions. The
guarantee is only valid should the product be used
in the manner intended and in accordance with
the instructions.
Notes and warnings
Warning for appliance with R290 refrigerant
gas (refer to the rating plate for the type of
refrigerant gas used).
CAUTION ON FIRE
READ THE MANUAL CAREFULLY
BEFORE USING THE APPLIANCE
R290 refrigerant gas complies
with European environmental directives.
This appliance contains R290 refrigerant
gas.
Appliance shall be installed, operated and
stored in a room with a oor area larger
than 12 m2.
For repair and maintenance; see manual
"Repair and maintenance - units with R290"
on www.frico.net.
To avoid damage, place the unit in an
upright position for at least 24 hours before
initiation.
The appliance shall be stored so as to
prevent mechanical damage from occurring.
When the portable air conditioner or
dehumidier is turned on, the fan can
work continuously stable under normal
conditions to provide the minimum
air volume of 100 m3/h even when
the compressor is closed due to the
temperature controller.
Do not pierce or burn.
Do not perforate any of the components in
the refrigerant circuit. Refrigerant gas may
be odourless.
The air conditioning (AC) is only suitable
for indoor use, and is not suitable for other
applications.
Place the AC in a at and dry place and keep
a distance of above 50 cm between the unit
and the surrounding objects or walls.
After the AC is installed, ensure that the
power plug is intact and rmly plugged into
the power outlet, and place the power cord
orderly to prevent someone from being
tripped or pulling out the plug.
Do not put any object into the air inlet and
outlet of the AC. Keep the air inlet and outlet
free from obstructions.
When drainage pipes are installed, ensure
that the drainage pipes are properly
connected, and are not distorted or bended.
Use a water trap if the hose is connected to
the drainage system.
While adjusting the upper and lower wind-
guide strips of the air outlet, pluck it with
hands gently to avoid damaging wind-guide
strips.
When moving the AC, make sure that it is in
an upright position.
The AC should stay away from gasoline,
ammable gas, stoves and other heat
sources.
Don't disassemble, overhaul and modify
the AC arbitrarily, otherwise it will cause
malfunction or even bring harm to
persons and properties. To avoid danger,
if failure occurs, ask the manufacturer or
professionals to repair it.
Do not install and use the AC in the
bathroom or other humid environments.
Do not pull the plug to turn off the AC.
Do not place cups or other objects on the
unit to prevent water or other liquids from
spilling into the AC.
Do not use insecticide sprays or other
ammable substances near the AC.
This appliance can be used by children
aged from 8 years and above and persons
with reduced physical, sensory or mental
capabilities or lack of experience and
knowledge if they have been given
supervision or instruction concerning use of
the appliance in a safe way and understand
the hazards involved. Children shall not
play with the appliance. Cleaning and user
maintenance shall not be made by children
without supervision.
Children of less than 3 years should be kept
away unless continuously supervised.
Children aged from 3 years and less than 8
years shall only switch on/off the appliance
provided that it has been placed or installed
in its intended normal operating position
and they have been given supervision or
instruction concerning use of the appliance
in a safe way and understand the hazards
involved.
Children aged from 3 years and less than 8
years shall not plug in, regulate and clean
the appliance or perform user maintenance.
2
3
4
1
5
6
9
10
11
12
14
16
13
15
17
18
19
20
7
8
Climobile
3
EN
Components
1 Control panel
2 Top cover
3 Swing hatch
4 Rear housing
5 Front housing
6 Omni-directional wheel
7 Vent hose
8 Window cover plate
9 Remote control
10 Rear housing
11 EVA lter housing
12 Power cord hook
13 Handle
14 Air vent
15 Continuous drainage hole
16 CON lter screen
17 Air inlet grille
18 Drainage hole
19 Power cord, 1.9 m
20 Plug
Features
Cooling, (heating), dehumidication and
ventilation function.
Automatic swing hatch in the outlet has
automatic air swing function, and the outlet
can be covered when the AC is turned off to
prevent dust from entering the unit.
LCD screen and LCD remote control to
facilitate operation. The remote control can
be placed on the back of the unit.
Handles on both sides.
The hooks to wrap the power cord on the
back facilitates users to hang the power
cord without hanging it down to the ground
and staining and damaging the power cord.
Air ltration capability.
Timer function.
Protection function of automatically
restarting the compressor after three
minutes, a variety of other protection
functions.


Specyfikacje produktu

Marka: Frico
Kategoria: Klimatyzator - Chłodnica powietrza
Model: CLIMOB09

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Frico CLIMOB09, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Klimatyzator - Chłodnica powietrza Frico

Frico

Frico Soloclim Instrukcja

9 Września 2024
Frico

Frico CLIMOB09 Instrukcja

9 Września 2024

Instrukcje Klimatyzator - Chłodnica powietrza

Najnowsze instrukcje dla Klimatyzator - Chłodnica powietrza