Instrukcja obsługi Field Controls AIR BOOSTER KS-4,5,6,8

Field Controls wiatrak domowy AIR BOOSTER KS-4,5,6,8

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Field Controls AIR BOOSTER KS-4,5,6,8 (12 stron) w kategorii wiatrak domowy. Ta instrukcja była pomocna dla 14 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/12
AIR BOOSTER
Model: KS-4,5,6,8
The EVENAIR® Air Booster is designed to increase the flow of heated or
cooled air in branch ducts of a heating and central air conditioning system.
The EVENAIR® can also be used to improve the air flow of a gravity warm air
furnace.
PRODUCT QUESTIONS
PHONE FIELD FIRST
for answers on product
maintenance, operation or
replacement part questions.
Phone:(252)522-3031
E-mail:fieldtec@fieldcontrols.com
English ....... Page 1
Français ..... Page 5
Espanõl ...... Page 8
Page 2
GENERAL INFORMATION
The EVENAIR® should be installed in branch ducts serving individual rooms, where proper air flows cannot be achieved.
The EVENAIR® is not designed for installation in the main air supply ducts. Locating the EVENAIR ® near the outlet end of
a problem branch duct will provide the best performance.
The EVENAIR® is designed to operate in round metal or flexible type ducts.
EXAMPLE: Use the 6" KS EVENAIR® for 6" ducts and the 8" KS EVENAIR® for 8" ducts. For larger duct diameters than
indicated or for rectangular ducts, use the Model JR-1 or JR-2 EVENAIR ® or the Model AB-1 Air Booster.
CAUTION: The EVENAIR® should not be installed into vertical duct pipes. Do not use this product on clothes dryer vent
pipe.
UNIT DIMENSIONS
MODEL “A” “B”
4” KS 4” 7-1/2
5” KS 5” 7-1/2
6” KS 6” 7-1/2
8” KS 8” 7-1/2
ELECTRICAL DATA
MODEL VOLTS AMPS HZ WATTS RPM
THERMAL OR
IMPEDANCE
PROTECTION
MAXIMUM
TEMP
RATING*
4” KS 120AC .29 60 19 3000 YES 15
5” KS 120AC .5 60 30 3000 YES 15
6” KS 120AC .6 60 35 3000 YES 18
8” KS 120AC .8 60 45 3000 YES 16
*Do not install the EVENAIR® where the air temperature within the duct exceeds rated
temperature.
Page 3
Figure 3A
Figure 3B
INSTALLATION INSTRUCTIONS
Locate the EVENAIR® in the duct pipe near the problem area.
Allow adequate space for the removal of the unit for servicing
or annual inspection.
FOR METAL DUCT PIPE 1
1. Separate the duct at a joint near the problem area and cut
6-3/4" off the end of the duct pipe. (See Figure 1)
2. An alternative method is to cut a 5-3/4" section out of the
duct pipe. (See Figure 2) Then crimp the end of the duct
pipe with at least 1" crimp. (See Figure 3)
3. Install the EVENAIR® unit with the crimped end pointing toward the problem area.
(See Figure 3) Secure the unit with sheet metal screws and seal joints with duct tape.
Support the unit with an acceptable hanging method.
4. (Complete this step for KS-5, KS-6 & KS-8 ONLY.) Remove center knockout from the
outlet box bottom. (See Figure 3A) Before installing the EVENAIR ® into the duct pipe,
fasten the outlet box onto the unit housing with the #10-32 UNF screws and nuts
provided. (See Figure 3B)
FOR FLEXIBLE DUCT
1. Cut and separate the exible duct. Fold back the outer insulation on the duct
to expose the flexible duct material. (See Figure 4)
2. Insert the EVENAIR® unit, with the crimped end pointing toward the problem
area, into the exible duct and secure with duct tape. (See Figure 4)
3. Support the unit with acceptable hanging method. Then re-install outer
insulation and secure with duct tape. Allow room for installation of an
electrical junction box.
Figure 1
Figure 2
Figure 3
Figure 4

Specyfikacje produktu

Marka: Field Controls
Kategoria: wiatrak domowy
Model: AIR BOOSTER KS-4,5,6,8

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Field Controls AIR BOOSTER KS-4,5,6,8, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje wiatrak domowy Field Controls

Instrukcje wiatrak domowy

Najnowsze instrukcje dla wiatrak domowy