Instrukcja obsługi Fetco CBS-2161XTS

Fetco ekspres do kawy CBS-2161XTS

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Fetco CBS-2161XTS (36 stron) w kategorii ekspres do kawy. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/36
Contact Information
FETCO ®
Food Equipment Technologies Company
600 Rose Road
Lake Zurich IL USA 60047-0429
Internet: www.fetco.com
©2013-2015 Food Equipment Technologies Company
PATENTS: WWW.fetco.com/patents
Phone: (800) 338-2699 (US & Canada)
(847) 719-3000
Fax: (847) 719-3001
Email: sales@fetco.com
techsupport@fetco.com
P141 REV:002 [1/16] ©December 2015
www.fetco.com
User’s Guide and Operator Instructions
Models: CBS-2161XTS CBS-2162XTS
Three gallon single and twin brewers.
Shown with D012: 3.0 Gallon LUXUS® Thermal Dispenser (TPD-30), not included
Extractor Touch Screen Commercial Hot Beverage Equipment
Table of Contents
Specifications and Requirements...................................2
I
In
ns
st
tr
ru
uc
ct
ti
io
on
ns
s
f
fo
or
r
b
br
re
ew
w
o
op
pe
er
ra
at
ti
io
on
n-
-f
fa
as
st
t
b
br
re
ew
w .......................4
Service Menu: Access and XTS menu tree....................6
Menu Features: Batch Parameters.................................7
How to calibrate the flow rate .......................................11
Error Codes ..................................................................13
Operator Training..........................................................14
Service Guide to a Successful Installation ...................15
Installation Directions....................................................16
Cleaning & Maintenance...............................................20
Go to fetco.com for the latest version of all information 2 P141 REV:002 revised 1/2016 ©December 2015
Specifications and Requirements
Water Requirements: Coffee Filter Size:
CBS-2160XTS: 20-75 psig, (138-517kPa) 2 gpm (7.60 lpm) 20” X 8” – standard FETCO # F004
Cold Water Supply Only 18” X 7½” - optional half batch FETCO # F005
Water inlet fitting is a 3/8 inch male flare. Electrical: See electrical configuration chart.
Brew Volume: Temperature, as set by factory:
Full Batch 3 gal. (11.4 lit.) All batches are user configurable 200°F (93°C) inside water tank (at sea level)
Total Brew Cycle—Factory setting: CBS-2162XTS: 6 1/2 Minutes CBS-2161XTS 6 Minutes
Weights and Capacities
Brewer Model Weight
(empty)
Water tank
Capacity & Weight.
Weight
(filled)
*Dispenser
Weight, ea.
*Dispenser
Filled, ea.
*Total Weight Brewer
& Dispensers, Filled
CBS-2161XTS 88 lbs.
(40kg)
8.7 gal.
(33 l)
72 lbs.
(32.7kg)
160 lbs.
(72.5kg)
18 lbs
(8.2kg)
42.5 lbs
(19.3kg)
202.5 lbs.
(92kg)
CBS-2162XTS 130 lbs.
(59kg)
16.3 gal.
(62 l)
136 lbs.
(62.1kg)
266 lbs.
(120.7kg)
18 lbs.
(8.2kg)
42.5 lbs
(19.3kg)
349 lbs.
(158.3kg) (2 dispensers)
* Based on TPD-30 Series Dispensers
Measurements
Brewer Model Height Width Depth Empty weight Shipping weight
CBS-2161XTS 41 ¼ in. (1048mm) 17 in. (454mm) 22½ in. (57cm) 88 lbs. (40kg) 96 lbs. (44kg)
CBS-2162XTS 41 ¼ in. in. (1048mm) 32 (813mm) 22½ in. (57cm) 130 lbs. (59kg) 140 lbs. (63.6kg)
CBS-2160XTS—3-gallon version Dimensions & Utility Connections Rough-in Drawings
Rou
g
h-in CBS-2161XTS —Sin
g
le station version 3-
g
allon version Drawin
g
#1201.00025.00
Rough-in CBS-2162XTS—Dual station 3-gallon version Drawing#1201.00024.00
Go to fetco.com for the latest version of all information 3 P141 REV:002 revised 1/2016 ©December 2015
All brewers HARDWIRE to an internal TERMINAL BLOCK See wiring diagrams for connections
North America CBS-2161XTS—Single 3 gallon version Electrical Configurations
Configuration
Code
Heater
Configuration Voltage Phase Wires KW Amp Draw Gallon/[liter]Hour
(3 gallon per batch)
E216151 3 X 3.0 kW 200-240 3 3L+G 6.4-9.1 18.6-22.5 16.4-23.4 [62-88]
(*Optional) 2 X 3.0 kW 200-240 1 2L+G 4.6-6.1 21.2-25.8 11.8-15.7 [44-59]
E216152 3 X 4.0 kW 200-240 3 3L+G 8.4-12.1 24.7-28.9 21.6-30 [82-113]
(*Optional) 2 X 4.0 kW 200-240 1 2L+G 6.1-8.1 28.1-33.8 15.6-20.8 [59-79]
E216153 3 X 5.0 kW 200-240 3 3L+G 10.5-15.1 30.7-36.1 27-30 [102-113]
(*Optional) 2 X 5.0 kW 200-240 1 2L+G 7.6-10.1 35.1-42.2 19.6-26 [74-98]
*Sold as three phase, highest power version
E
q
ui
p
ment ma
y
be field confi
g
urable to sin
g
le
p
hase, lowe
r
-
p
ower, sin
g
le-
p
hase confi
g
uration usin
two heaters.
North America CBS-2162XTS—Twin 3 gallon version Electrical Configurations
Configuration
Code
Heater
Configuration Voltage Phase Wires KW Amp Draw Gallon/[liter]Hour
(3 gallon per batch)
E216251 3 X 3.0 kW 200-240 3 3L+G 6.4-9.1 18.6-22.5 16.4-23.4 [62-88]
E216252 6 X 3.0 kW 200-240 3 3L+G 12.6-18.1 36.4-43.7 32.4-46.5[123-176]
E216253 3 X 4.0 kW 200-240 3 3L+G 8.4-12.1 24.7-28.9 21.6-28.9 [82-113]
E216254 6 X 4.0 kW 200-240 3 3L+G 16.8-24.1 48.4-58.1 43.1-60 [163- 227]
E216272 6 X 3.0 kW 440-480 3 3L+G 13.6-18.1 19.4-22.2 33.2-44 [126-167]
E216271 6 X 4.0 kW 440-480 3 3L+G 20.3-24.1 26.6-29.4 52.2- 60 [197- 227]
International, North America and Japan CBS-2161XTS—Single 3 gallon version Electrical Configurations
Configuration
Code
Heater
Configuration Voltage Phase Wires KW Amp Draw Gallon/[liter]Hour
(3 gallon per batch)
E216151* 3 X 3.0 kW 200-240 3 3L+G 6.4-9.1 18.6-22.5 16.4-23.4 [62-88]
E216152* 3 X 4.0 kW 200-240 3 3L+G 8.4-12.1 24.7-28.9 21.6-28.9 [82-113]
E216153* 3 X 5.0 kW 200-240 3 3L+G 10.5-15.1 30.7-36.1 27-30 [102-113]
*Sold as three phase, highest power version
Equipment may be field configurable to single phase, lower-power, single-phase configuration using two heaters as in domestic version
International CBS-2161XTS—Single 3 gallon version Electrical Configurations
Configuration
Code
Heater
Configuration Voltage Phase Wires KW Amp Draw Gallon/[liter]Hour
(3 gallon per batch)
E216191 3 X 3.0 kW 220-240/380-415 3 3L,N+G 7.6-9.1 11.7-12.7 19.6-23.4 [74-88]
E216192 3 X 4.0 kW 220-240/380-415 3 3L,N+G 10.2-12.1 15.5-16.9 26.2-28.9 [99-113]
E216193 3 X 5.0 kW 220-240/380-415 3 3L,N+G 12.7-15.1 19.3-21.0 32.6-37.8 [116-125]
CE CBS-2161XTS—Single 3 gallon version Electrical Configurations
E216161 3 X 3.0 kW 230/400 3 3L, N+PE 8.6 12.4 22.2 [84]
E216162 3 X 4.0 kW 230/400 3 3L, N+PE 11.3 16.4 30 [114]
International, North America and Japan CBS-2162XTS—Twin 3 gallon version Electrical Configurations
Configuration
Code
Heater
Configuration Voltage Phase Wires KW Amp Draw Gallon/[liter]Hour
(3 gallon per batch)
E216252 6 X 3.0 kW 200-240 3 3L+G 12.6-18.1 36.4-43.7 32.4-46.5[123-176]
E216254 6 X 4.0 kW 200-240 3 3L+G 16.8-24.1 48.4-58.1 43.1-60 [163- 227]
E216291 3 X 5.0 kW 220-240/380-415 3 3L,N+G 12.7-15.1 19.3-21.0 32.6-37.8 [116-125]
E216292 6 X 3.0 kW 220-240/380-415 3 3L,N+G 15.1-18.1 22.9-25.0 38-44 [144-167]
CE CBS-2162XTS—Twin 3 gallon version Electrical Configurations
E216261 3 X 4.0 kW 230/400 3 3L, N+PE 11.3 16.4 30 [114]
E216262 3 X 5.0 kW 230/400 3 3L, N+PE 14.1 20.4 36.2 [137]

Specyfikacje produktu

Marka: Fetco
Kategoria: ekspres do kawy
Model: CBS-2161XTS

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Fetco CBS-2161XTS, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje ekspres do kawy Fetco

Fetco

Fetco CBS-1252 Instrukcja

16 Września 2024
Fetco

Fetco CBS-1151-XV+ Instrukcja

15 Września 2024
Fetco

Fetco CBS-1231 Instrukcja

13 Września 2024
Fetco

Fetco Luxus L4S-15 Instrukcja

11 Września 2024
Fetco

Fetco Luxus LGD-10 Instrukcja

11 Września 2024
Fetco

Fetco CBS-62H Instrukcja

9 Września 2024
Fetco

Fetco CBS-2152XTS Instrukcja

7 Września 2024
Fetco

Fetco CBS-2141XTS Instrukcja

5 Września 2024

Instrukcje ekspres do kawy

Najnowsze instrukcje dla ekspres do kawy

Russell Hobbs

Russell Hobbs Retro Instrukcja

15 Października 2024
Bialetti

Bialetti Kitty Instrukcja

14 Października 2024
Exquisit

Exquisit KA 6502 sw Instrukcja

14 Października 2024
Royal Catering

Royal Catering RCKM-20 Instrukcja

14 Października 2024
Royal Catering

Royal Catering RC-CU9 Instrukcja

14 Października 2024
Rowenta

Rowenta CT500 Silver Art Instrukcja

12 Października 2024
Krups

Krups Vertuo Next Instrukcja

11 Października 2024