Instrukcja obsługi Extron XPA U 1004

Extron odbiornik XPA U 1004

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Extron XPA U 1004 (3 stron) w kategorii odbiornik. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/3
1
IMPORTANT:
Go to www.extron.com for the complete
user guide, installation instructions, and
specifications before connecting the
product to the power source.
XPA Ultra Series Audio Power Amplifiers • Setup Guide
(XPA U 358, XPA U 358-70V, XPA U 358-100V, XPA U 358C-70V, XPA U 358C-100V, XPA U 1004,
XPA U 1004-70V, XPA U 1004-100V, XPA U 1004C-70V, XPA U 1004C-100V, XPA U 1002,
XPA U 1002-70V, XPA U 1002-100V)
WARNING: Installation and service must be performed by experienced, professional installers only.
AVERTISSEMENT : L’installation et l’entretien doivent être effectués par des installateurs professionnels
expérimens.
This guide provides startup instructions for experienced, professional installers to set up and operate the XPA Ultra Series audio
power ampliers. All references are to the XPA Ultra Series User Guide which can be found on www.extron.com.
Step 1 — Powering Down Equipment
Be sure that power to the amplier is turned off rst.
NOTE: Adjust the audio level to (full attenuation) prior to powering the amplier in Step 7 on page3.=
Turn off all other equipment and disconnect the power cables. Verify that the amplier is disconnected from the power source
before proceeding.
Step 2 — Mounting and Applications
Rack Mounting
The XPA Ultra Series ampliers can be rack mounted using one of the following methods.
NOTE: See the XPA Ultra Series User Guide for instructions on mounting to a rack shelf.
Rack Ear Mounting (Single Unit)
The XPA Ultra Series ampliers ship with a set of rack ears so the half rack-width ampliers can be installed in a full rack-width
space.
Mount the amplifier with the rack ears as follows:
1. If feet were installed on the bottom of the amplier, remove them.
2. Attach the included rack ears to the sides of the amplier with the four provided #6 machine screws (
1 in the gure below).
3. Insert the amplier into the rack, align the holes in the rack ears with the holes on the rack.
4. Secure the amplier to the rack using four provided 10-32 x 3/4” screws (2 in the gure below).
e
XPA U 1 004 SER IES
1 2 3 4
OVER
TEMP
LIMITE R/PRO T E C T
S IGNAL
POWER AMPL IFIERS
1
e
XPA U 10 04 SER IES
1234
OVER
TEMP L IMITER/P ROT E C T
S IGNAL
POWER AMPL
IFIERS
2
2
Bridge Plate Rack Mounting (Side-by-Side Units)
The XPA Ultra Series ampliers ship with a bridge plate connector for connecting two XPA Ultra Series ampliers together to form
a full rack-width unit.
Connect and mount two XPA Ultra Series amplifiers as follows:
1. If feet were installed on the bottom of the ampliers, remove them.
2. Position the two ampliers upside down and next to each other (see the gure below).
3. Use the bridge plate connector and four provided #4 machine screws to connect the two ampliers together (1 in the gure
below).
4. Attach the two short rack ears to the ampliers with four provided #6 machine screws (
2 in the gure below).
5. Insert the ampliers into the rack, align the holes in the rack ears with the holes on the rack.
6. Secure the amplier to the rack using four provided 10-32 x 3/4” screws (3 in the gure below).
e
XPA U 1
0
04 SERIES
1 2 3 4
OVER
TEMP LIMITE R/P RO T E
CT
SIG NAL
POWER AMPLIFIERS
e
XPA U 1004 SERIES
1 2 3 4
OVER
TEMP L
IMITER/P R
OTE C T
S
IGNAL
POWER AMPLIFIE RS
Mounting
screws (4)
2
1
e
XPA U 1004 S ERIE
1 2 3 4
OVER
TEMP LIMITER/PROTECT
SIGNAL
POWER AMPLIFIER
E
RS
e
XPA U 1004 S ERIES
1 2 3 4
OVER
TEMP LIMITER/PROTECT
SIGNAL
POWER
AMPL
IFIERS
3
Rack Mounting Ventilation Recommendations
Excessive heat can decrease the optimal lifetime of the power amplier.
An over temp indicator LED on the front panel of the amplier lights red
whenever the recommended operating temperature has been exceeded.
To reduce the chances of an over temp condition, the XPA Ultra ampliers
should be arranged in a rack environment so the environment around the
amplier does not reach or exceed +122 °F (+50 °C). No more than four
stacks of XPA Ultra ampliers should be arranged one-on-top-of-the-other
in a rack without an open space between the stacks (see the gure to the
right).
XPA Ultra ampliers can also be arranged above or below another
non-XPA Ultra device. In this case, the environment around the amplier
should not reach or exceed +122 °F (+50 °C).
Step 3 — Captive Screw Audio Cable Wiring
Wire the source output to the amplier 3.5 mm captive screw input connectors as shown in the following illustrations.
Balanced Stereo Input
Tip
Ring
Tip
Ring
Slee
ves
L R
Unbalanced Stereo Input
Tip
Sleeve
Sleeve
Tip
L R
Do not tin
the wires!
Balanced Dual Mono Input
Tip
Ring
Slee (s)ve
Tip
Ring
L R
Unbalanced Dual Mono Input
Tip
Sleeve
Tip
Sleeve
L R
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space
3
68-3149-01 Rev. B
01 19
© 2018-2019 Extron Electronics — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Step 4 — Speaker Wiring
Wire the speakers to the amplier output using the included 4-pole screw-lock captive screw connector as shown below.
1 2
8Ω/4Ω OUTPUTS
1 2
70V OUTPUTS
1 2
100V OUTPUTS
ATTENTION:
Do not tie channel output pins to each other or to ground. Doing so will short out the outputs, damage the amplier, or
both.
Ne pas lier les sorties 1 et 2 des canaux entre elles ou à la terre. Les sorties pourraient être court-circuitées et/ou
l’amplicateur pourrait être endommagé.
To avoid risk of damage to the amplier or the speakers, always connect low-impedance speaker loads (8Ω/4Ω) and
high-impedance speaker loads (70V) to the appropriately marked output connectors on the amplier.
Pour éviter tout risque de détérioration de l’amplicateur ou des enceintes, connectez toujours les charges de l’enceinte
faible impédance (8Ω/4Ω) et les charges de l’enceinte haute impédance (70V) aux connecteurs de sortie correctement
identiés sur l’amplicateur.
NOTE: You must use Class 2 wiring for this output to comply with UL requirements.
Step 5 — Setting the High-Pass Filter (HPF)
On XPA Ultra 70V and 100V models, jumper the and pins together to disable the internal 80 Hz high-pass lter. OFF G
This function should only be used when high-pass ltering is applied to the signal before it reaches the amplier.
Step 6 — Remote Port Wiring
On the XPA Ultra Series ampliers, the 3.5 mm 2-pole captive screw remote port is used to remotely place the amplier
into standby. Connecting the pin to the pin places the amplier in standby mode. Standby mode turns off Standby G
all output, although the amplier is still receiving power. Use the included 3.5 mm 2-pole captive screw connector to
remotely ground the pin. The power indicator LED lights amber when the amplier is in standby mode.Standby
NOTE: A 10k ohm resistor is included in the box. If this resistor is connected between the pin and Standby
ground, the auto-standby timer is defeated. The pin can still be shorted to the ground pin to force the Standby
amplifier into standby.
Step 7 — Powering On Equipment
ATTENTION:
The amplier must be powered on last.
L’amplicateur doit être mis sous tension en dernier.
Reconnect all power cables and switch on all other equipment before powering on the power amplier. The front panel power
LED of the amplier lights green.
Step 8 — Adjusting Attenuation
Adjust the audio attenuation using the rear panel adjustment potentiometers as shown to the right
(see Rear Panel Features and Operation in the XPA Ultra Series User Guide for more information).
Step 9 — Checking LEDs
Check the limiter/protect and signal LEDs located on the front and rear panels if problems are encountered (see Rear Panel
Features and Operation in the XPA Ultra Series User Guide for more information).
HPF
G OFF
REMOTE
G
STANDBY
ATTENUATION
1 2
3 4
5 6
7 8
0
2
4
6
8
10
14
18
26
12
0
2
4
6
8
10
14
12
0
2
4
6
8
10
14
12
0
2
4
6
8
10
14
12
0
2
4
6
8
10
14
18
26
12
0
2
4
6
8
10
14
12
0
2
4
6
8
10
14
12
0
2
4
6
8
10
14
12


Specyfikacje produktu

Marka: Extron
Kategoria: odbiornik
Model: XPA U 1004

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Extron XPA U 1004, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje odbiornik Extron

Extron

Extron XTP R HWP 201 4K Instrukcja

9 Października 2024
Extron

Extron DP DA2 Instrukcja

9 Października 2024
Extron

Extron DA HD 8K L Instrukcja

9 Października 2024
Extron

Extron XTP SFR HD 4K Instrukcja

9 Października 2024
Extron

Extron XPA U 1002 Instrukcja

9 Października 2024
Extron

Extron XPA U 2004 FX Instrukcja

9 Października 2024
Extron

Extron XPA U 1004 SB Instrukcja

9 Października 2024
Extron

Extron XPA U 358 Instrukcja

9 Października 2024
Extron

Extron XPA U 358C Instrukcja

9 Października 2024
Extron

Extron XPA U 758 Instrukcja

9 Października 2024

Instrukcje odbiornik

Najnowsze instrukcje dla odbiornik

Denon

Denon AVR-S900W Instrukcja

15 Października 2024
Pro-Ject

Pro-Ject Amp Box DS2 Instrukcja

15 Października 2024
AKG

AKG HP12U Instrukcja

15 Października 2024
Apart

Apart SBR160 Instrukcja

14 Października 2024
American Audio

American Audio VLP 600 Instrukcja

14 Października 2024
Chord

Chord Anni Instrukcja

14 Października 2024
Sennheiser

Sennheiser EM 9046 SU Instrukcja

14 Października 2024
Yamaha

Yamaha MusicCast RX-V481 Instrukcja

13 Października 2024
JL Audio

JL Audio VX600/6i Instrukcja

12 Października 2024
Pioneer

Pioneer SX-303RDS Instrukcja

10 Października 2024