Instrukcja obsługi Extech MN15A

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Extech MN15A (13 stron) w kategorii Multimeters. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/13
User's Guide
Mini Digital Multimeter
Model MN15A
A
MN15A-en-US_1.4 4/15 2
Introduction
Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers AC/DC Voltage,
AC/DC Current, Resistance, Diode, and Continuity testing plus Type K thermocouple temperature
measurements. Proper use and care of this meter will provide many years of reliable service.
Safety
This symbol adjacent to another symbol, terminal or operating device indicates
that the operator must refer to an explanation in the Operating Instructions to
avoid personal injury or damage to the meter.
This WARNING symbol indicates a potentially hazardous situation, which if not
avoided, could result in death or serious injury.
This CAUTION symbol indicates a potentially hazardous situation, which if not
avoided, may result damage to the product.
This symbol advises the user that the terminal(s) so marked must not be
connected to a circuit point at which the voltage with respect to earth ground
exceeds 600V.
This symbol adjacent to one or more terminals identifies them as being associated
with ranges that may, in normal use, be subjected to particularly hazardous
voltages. For maximum safety, the meter and its test leads should not be handled
when these terminals are energized.
This symbol indicates that a device is protected throughout by double insulation or
reinforced insulation.
SAFETY INSTRUCTIONS
This meter has been designed for safe use, but must be operated with caution. The rules listed
below must be carefully followed for safe operation.
1. NEVER apply voltage or current to the meter that exceeds the specified maximum:
Input Protection Limits
Function Maximum Input
VDC or VAC 600VAC and VDC
VDC or VAC 200mV range 200Vrms
mA AC/DC 200mA 250V fast acting fuse
A AC/DC 10A 250V fast acting fuse
(for 30 seconds max. every 15 minutes.)
Resistance, Continuity 250Vrms for 15 sec. max.
2. USE EXTREME CAUTION when working with high voltages.
3. DO NOT measure voltage if the voltage on the "COM" input jack exceeds 600V above earth ground.
4. NEVER connect the meter leads across a voltage source while the function switch is in the current, resistance, or
diode mode. Doing so can damage the meter.
5. ALWAYS discharge filter capacitors in power supplies and disconnect the power when making resistance or diode
tests.
6. ALWAYS turn off power and disconnect test leads before opening the covers to replace the fuse or battery.
7. NEVER operate the meter unless the back cover and the battery and fuse covers are in place and fastened securely.
8. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may
be impaired.
WARNING
CAUTION
MAX
600V
MN15A-en-US_1.4 4/15 3
Controls and Jacks
1. LCD display
2. Rotary function switch
3. 10 ampere test lead jack
4. Test lead jack for voltage, milliamp,
resistance/continuity, diode and temperature functions
5. COM test lead jack
6. Battery compartment (rear)
SYMBOLS
•))) Continuity Diode
AC DC
M megga (106 ) (ohms) m milli (10-3) (volts, amps)
k kilo (103 ) (ohms) V Volts
A Amps  Ohms
BAT Battery test °C Degrees Celsius
°F Degrees Fahrenheit Low battery indicator

Specyfikacje produktu

Marka: Extech
Kategoria: Multimeters
Model: MN15A

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Extech MN15A, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Multimeters Extech

Instrukcje Multimeters

Najnowsze instrukcje dla Multimeters