IMPORTANT: Read all the instructions in this manual. Failure
to comply with the instructions in this manual or use of the
device, in ways other than the ones mentioned in this manual,
may result in hazardous radiation exposure.
Safety Use & Care
Features & Specifications
Function Diagram
• Laser guided targeting for aiming precision
• Narrow distance-spot ratio for accurate results at greater distances
• Safely measure hazardous or inaccessible objects
• Standard 9V battery powers up to 12 hours of cumulative use
• Auto-off after 15 seconds of inactivity
• Measurement Range: -58°F ~ 1022°F (-50°C ~ 550°C)
• Accuracy: ±2% / ±2°C
• Resolution: 0.1°F / °C
• Maximum Output: < 1 mW
• Wavelength: 630 - 670 nm
• Distance-Spot Ratio: 12:1
• Response Time: < 500 ms
• Emissivity(Adjustable): 0.1 - 1.0
• Battery: DC 9V
1. LCD Display
2. Display Backlight On/Off
3. Laser Pointer/UP
4. Unit (°C/°F)/DOWN
5. Emissivity Adjustment Mode
6. Laser Hole
7. IR Sensor
8. Measurement Trigger
9. Battery Compartment
Operation
Surface Temperature Measurement
NOTE: The Lasergrip cannot measure the temperature of objects behind
glass. Inaccuracy may also occur when exposed to steam, dust or any
other contaminants in the air.
1. Once the battery is properly installed, press the measurement trigger to
activate the device.
2. Point the Lasergrip towards the surface of measurement.
3. Press and hold the measurement trigger and the laser will activate for
aiming guidance.
4. Keep holding the trigger as you move the Lasergrip if you wish to live
scan the surface area for temperature measurement.
5. Once the laser is pointed to the desired point of measurement, release
the trigger and the LCD display will lock the calculated temperature.
6. Press the measurement trigger once again to make another
measurement.
HOLD for continuous
temperature reading
RELEASE to lock the
temperature result
NOTE: The Lasergrip LCD will display ‘OH’ when the measured
temperature is above the measurable range, and will display ‘OL’ when the
measured temperature is below the measurable range.
NOTE: The Lasergrip cannot measure the temperature of objects behind
glass. Inaccuracy may also occur when exposed to steam, dust or any
other contaminants in the air.
The device warning and aperture safety
information are also labeled directly on
the device; the sticker is located on the
right side of the Lasergrip.
Any updates to the product information
(date of manufacturing and
manufacturer address) will be added as
adhesive overlays.
The device certification information is
labeled directly on the device. The
sticker is located on the left side of the
Lasergrip.
Warranty Information
Etekcity warrants all products to be of the highest quality in material,
craftsmanship, and service, effective from the date of purchase to the end
of the warranty period.
Etekcity will replace any product found to be defective due to
manufacturer flaws based on eligibility. Refunds are available within
the first 30 days of purchase. Refunds are only available to the original
purchaser of the product. This warranty extends only to personal use and
does not extend to any product that has been used for commercial, rental,
or any other use in which the product is not intended for. There are no
warranties other than the warranties expressly set forth with each product.
This warranty is non-transferrable. Etekcity is not responsible in any
way for any damages, losses, or inconveniences caused by equipment
failure by user negligence, abuse, or use noncompliant with the user
manual or any additional safety, use, or warnings included in the product
packaging and manual.
This warranty does not apply to the following:
• Damage due to abuse, accident, alteration, misuse, tampering, or vandalism.
• Improper or inadequate maintenance.
Distance-Spot Ratio
For the most accurate results, make sure the two guidance lasers overlap
at a single point. The space between the two lasers marks the the area of
measurement. Insufficient surface area will result in inaccurate results.
The recommended distance to hold the Lasergrip from the surface of
measurement is 14.17 in (36 cm). This creates a spot measurement area of
1.18 inches (3 cm) in diameter.
The Lasergrip 1022D measures surface temperature on the basis of
distance to spot diameter ratio (D:S). As the distance betweer the
thermometer and the surface increases, the total surface area measured
will also increase. With a distance to spot ratio of 12:1 the surface area
measured has a diameter of roughly 1/12 the distance.
If you encounter any issues or have any questions regarding your new
product, please contact our helpful Customer Support Team. Your
satisfaction is our goal!
Customer Support
Etekcity and its subsidiaries assume no liability for damage caused by the
use of the product other than for its intended use or as instructed in the
user manual. Some states do not allow this exclusion or limitation of
incidental or consequential losses so the foregoing disclaimer may not
apply to you. This warranty gives you specific legal rights and you may
also have other rights which may vary from state to state.
ALL EXPRESSED AND IMPLIED WARRANTIES, INCLUDING THE
WARRANTY OF MERCHANTABILITY, ARE LIMITED TO THE PERIOD OF THE
LIMITED WARRANTY.
Additional 1-Year Warranty
You can extend your 1-year warranty by an additional year. Log onto
www.etekcity.com/warranty and enter your order number (for example,
from Amazon or Houzz) to register your new product for the extended
warranty.
If you are unable to provide the order number for your product, please
type a short note in the order number field along with the date you
received your product.
Defective Products & Returns
If your product proves defective within the specified warranty period,
please contact Customer Support via support@etekcity.com with your
order number. DO NOT dispose of your product before contacting us. Once
Customer Support has approved your request, please return the unit with
a copy of the invoice or your order number.
*Please have your order confirmation number ready before contacting
Customer Support.
Etekcity Corporation
1202 N Miller St., Suite A
Anaheim, CA 92806
USA
Toll Free: (855) 686-3835
Email: support@etekcity.com
Support Hours
Mon - Fri 9:00 am - 5:00 pm PST/PDT
Infrared Thermometer
Model No.: Lasergrip 1022D
Questions or Concerns?
(855)-686-3835 • support@etekcity.com
Thank you for purchasing the Lasergrip 1022D Infrared Thermometer by
Etekcity. This easy-to-use device lets you conveniently and accurately
measure surface temperatures from a distance without the need of any
direct contact. Should you have any questions or concerns, feel free to
contact our helpful customer support team toll-free at 855.686.3835 or
by email at support@etekcity.com.
WARNING: THIS DEVICE PRODUCES LASER RADIATION. USE CLASS 2
EXTREME CAUTION AT ALL TIMES WHEN LASER IS IN USE. DO NOT LOOK
INTO DIRECT OR REFLECTED LASER-LIGHT BEAM OR VIEW BEAM WITH
OPTICAL INSTRUMENTS. DO NOT AIM LASER-LIGHT AT ANOTHER
PERSON OR ANIMAL. LASER RADIATION MAY DAMAGE YOUR EYE. DO
NOT DISASSEMBLE THE DEVICE.
• DO NOT point the laser-light at another person or animal.
• DO NOT attempt to point laser-light at an aircraft.
• Avoid direct/indirect eye contact with the laser-beam. Laser radiation
may cause eye damage.
• DO NOT view the beam with optical instruments.
• In the vicinity of use, make any bystanders aware of the dangers of
looking directly into the laser beam.
• DO NOT allow children to operate the device.
• Use a 9V battery when replacing the battery within the device. Make
sure to insert the battery in accordance with the correct polarities.
• ALWAYS remove the batteries when cleaning the device.
• DO NOT use leaking batteries or dispose old batteries in fire.
• Remove the battery for storage if the device is not being used for a
prolonged period of time.
• DO NOT disassemble the device or tamper with internal components.
Doing so will void any warranty.
• DO NOT touch the lens or wipe it using anything other than a soft cloth
or cotton swab.
• Keep the thermometer away from electromagnetic fields produced by
objects such as arc welders and induction heaters.
• DO NOT expose the thermometer to direct sources of heat for extended
periods of time.
• The thermometer measures surface temperature, not internal
temperature. Do not use the Lasergrip as a reliable source to measure
body temperatures.
1. Low Battery
2. Laser On
3. Back-light On
4. Continue Scanning
5. °C / °F
6. Temperature Result
7. Max Temperature / Emissivity Result
8. Max Temperature Sian
9. Adjustable Emissivity Sign
Display Icon Key
Unit Conversion
To switch between units of temperature
measurement, press the °C/°F button at any time
while the Lasergrip is on.
Laser Activation
To activate and deactivate the laser, press the
laser pointer On/Off button at any time while the
Lasergrip is on.
Display Backlight Operation
To activate and deactivate the display backlight,
press the display backlight On/Off button at any
time while the Lasergrip is on.
Emissivity Adjustment &
Max Temperature
To adjust the emissivity value before
measurement, press the emissivity adjustment
mode button, then use the UP and DOWN
buttons to navigate to the desired value. You may
refer to the emissivity reference chart for correct
surface emissivity values. To transfer into Max
Temperature Mode, press the mode butt on again.
1. Open the battery compartment and remove the used battery. Dispose
the used battery properly.
2. Connect a new DC 9V battery, making sure it's under the correct
polarity.
3. Insert the battery into the compartment and close the compartment lid,
making sure the wiring is not being pinched by the compartment lid.
Battery Replacement
A low battery icon will appear on the LCD display when the Lasergrip's
battery power is running low. Immediately replace the battery when the
icon appears.
9V Battery
PAIR
Wiring is not
bulging out of the
compartment
Polarity facing
upward
Emissivity
FCC Declaration
The emissivity of a material is its efficiency in emitting thermal energy.
Non-reflective surfaces have a higher emissivity (closer to 1) than
reflective surfaces (closer to 0). Inaccurate results may occur when
measuring reflective surfaces such as glass, polished wood, and garnite.
To take accurate temperature measurement of reflective surfaces with
low emissivity, adjust the emissivity value before measurement using the
reference chart. Or, place a strip of masking tape over the surface and
allow for it to adjust to the temperature of the surface for approximately
30 minutes. Measure the surface, scanning the taped section, eliminating
the issue of inaccuracy.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received.
Including interference that may cause undesired operation.
Material Feature Emissivity Material Feature Emissivity
Emissivity Of Articles
Aluminium
Brass
Oxidized 0.3 0.98
0.02-0.04 0.20-0.60
0.5
0.7
0.02-0.05
0.70-0.90
0.85-0.95
0.85-0.920.75-0.80
0.83-0.90
0.96-0.98
0.95
0.95
0.98
0.80-0.90
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.94
0.94
0.94
0.5
0.80
0.90
0.90
0.9
0.96
0.90-0.98
0.90-0.96
0.92-0.96
0.89-0.91
0.7
0.90-0.95
0.96
0.85
0.97
0.90
0.93
0.93
0.95
Polished
Oxidized
Oxidized
Oxidized
Powered
Lackluster
Polished
Gold 0.01-0.10
Iron
Steel
Asbestos
Plaster
Asphalt
Rock
Wood
Charcoal
Carbon
Lacquerwork
Carbon Cement
Soap Bubble
Water
Snow
Ice
Frozen Foods
Ceramics
Limestone
Paint
Human Skin
Graphite
Plastic
Rubber
Plastic Cement
Concrete
Cement
Soil
Mortar
Brick
Marble
Textile
Paper
Sand
Clay
Sand
Glass
Textile
Heated Food
Plastic
Oil
Steel and iron
Wool
Lead
Natural
Oxidized
Non-
transparent
Oxidized
Package Contents
1 x Lasergrip 1022D
1 x 9V DC Battery
1 x User Manual
• Damage in return transit.
• Unsupervised use by children under 18 years of age.
Specyfikacje produktu
Marka: | Etekcity |
Kategoria: | termometr |
Model: | Lasergrip 1022D |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Etekcity Lasergrip 1022D, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje termometr Etekcity
17 Września 2024
17 Września 2024
Instrukcje termometr
- termometr PeakTech
- termometr AEG
- termometr Motorola
- termometr Beurer
- termometr Sanitas
- termometr Joy-It
- termometr Braun
- termometr Tefal
- termometr Voltcraft
- termometr Milwaukee
- termometr Philips
- termometr SilverCrest
- termometr Nedis
- termometr Stanley
- termometr Rossmax
- termometr Marquant
- termometr Quigg
- termometr Orbegozo
- termometr Citizen
- termometr Homedics
- termometr Silverline
- termometr Testo
- termometr TFA
- termometr Chauvin Arnoux
- termometr Scala
- termometr Uni-T
- termometr Medisana
- termometr Cuisinart
- termometr Auriol
- termometr IFM
- termometr Emerio
- termometr Owon
- termometr Beper
- termometr Techno Line
- termometr TrueLife
- termometr Emos
- termometr Trotec
- termometr Omron
- termometr Thomson
- termometr La Crosse Technology
- termometr Velleman
- termometr Arendo
- termometr Pyle
- termometr Waeco
- termometr Speco Technologies
- termometr Weber
- termometr Microlife
- termometr Fluke
- termometr Greisinger
- termometr Miniland
- termometr Bartscher
- termometr BeSafe
- termometr Kerbl
- termometr Westfalia
- termometr Clatronic
- termometr Telefunken
- termometr Oregon Scientific
- termometr Inventum
- termometr Innoliving
- termometr Bresser
- termometr Elro
- termometr Olympia
- termometr Hama
- termometr Taylor
- termometr Duronic
- termometr Omega
- termometr Medel
- termometr Boso
- termometr Terraillon
- termometr Esperanza
- termometr ZKTeco
- termometr Extech
- termometr Elta
- termometr Testboy
- termometr Geratherm
- termometr Respekta
- termometr SereneLife
- termometr Kyoritsu
- termometr Vemer
- termometr Klein Tools
- termometr Lanaform
- termometr Inkbird
- termometr Leifheit
- termometr Eurochron
- termometr Topcom
- termometr Sencor
- termometr Alecto
- termometr ADE
- termometr ProfiCare
- termometr Reer
- termometr Cotech
- termometr Ecomed
- termometr Salter
- termometr TensCare
- termometr Veroval
- termometr AnD
- termometr Amprobe
- termometr ATN
- termometr Kruidvat
- termometr Easypix
- termometr Cresta
- termometr GlobalTronics
- termometr Flir
- termometr AcuRite
- termometr Summer
- termometr Technoline
- termometr Vicks
- termometr Welch Allyn
- termometr BabyOno
- termometr Laica
- termometr Mabis
- termometr Turbotech
- termometr Irox
- termometr Konig
- termometr Save Demp
- termometr Comark
- termometr Fora
- termometr Beaba
- termometr Grado
- termometr La Crosse
- termometr Hartig And Helling
- termometr Pacom
- termometr Bioland
- termometr Global Tronics
- termometr Levita
- termometr Blue Circle Medical
- termometr Okoia
- termometr Silvergear
- termometr Uebe
- termometr Dittmann
- termometr Sensitec
- termometr TFA Dostmann
- termometr CDN
- termometr Emga
- termometr Hartmann
- termometr Premiumful
- termometr MostEssential
- termometr VDH
- termometr Telesystem
- termometr Pancontrol
- termometr General
- termometr Ebro
- termometr Arya
- termometr RK Technology
- termometr Mobi
- termometr TQC
- termometr Bintoi
- termometr Jumper
- termometr Elem6
- termometr Thermoval
- termometr FlinQ
- termometr Pasha
- termometr Innovo
- termometr Delta Ohm
- termometr Guide
- termometr InfiRay
- termometr Knikker
- termometr AvaTemp
- termometr EasyLife
- termometr Alter
- termometr Yummly
- termometr Eks
- termometr Gima
- termometr Aspen
- termometr Salva Tec
- termometr Radiant
- termometr Kuchenprofi
- termometr WBTT
- termometr Welby
- termometr Prologue
- termometr A&D
- termometr ClimeMET
Najnowsze instrukcje dla termometr
8 Grudnia 2024
8 Grudnia 2024
8 Grudnia 2024
8 Grudnia 2024
8 Grudnia 2024
8 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024