Instrukcja obsługi Erica Synths Black VC Clock v2

Erica Synths nieskategoryzowany Black VC Clock v2

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Erica Synths Black VC Clock v2 (2 stron) w kategorii nieskategoryzowany. Ta instrukcja była pomocna dla 10 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
THANK YOU FOR PURCHASING
ERICA SYNTHS MODULE!
Erica Black Series include high-end,
unique functionality and superior quality
modules. Only the best, highest quality
components are used, all inputs and
outputs are protected against undesired
overvoltage. Erica Black series consist of
range of modules that are needed to put
together entire synth. Enjoy!
Erica Black VC Clock is a beating
heart of your modular system. The
module generates several clock signals
simultaneously and has advanced
features (tap tempo, shue, divide) both
for controlled, rhythmic music production
and for experiments with high level of
uncertainty. You may find interesting
adjustable and even random duty circle
of shuing and random clock outputs.
Bonus feature – the module can be used
as a performance time stopwatch.
FEATURES:
Manually and CV adjustable BPM
Clock division and multiplication
External clock input
3 digit BPM indicator
Manually and CV controllable shue
amount
Manual and programmable sequencer
reset output
Sequencer reset output
Adjustable duty circle of shuing and
random clock
Performance time stopwatch
TECHNICAL SPECIFICATIONS:
Max input level -10V - +10V ..........................
Clock signal level 0 - +5V .............................
Clock rate .............................. 30 – 400BPM
CV input level (full sweep) -5V - +5V ..........
Power consumption 40mA@+12V, ..............
5mA@-12V
Module width ....................................... 10HP
Module depth 25mm ....................................
7 segment LED indicators show BPM
of Clock Out
Use Tap tempo button to set BPM.
Push and hold TAP button and rotate
SHFL/RND potentiometer to set clock
output probability on RND OUT
Pushing RST button sends high pulse
on RST output. Use it to reset your
sequencer!
This is sequencer reset output. Each
time the RST button is pushed, high
signal appears here to reset the
sequencer
You can Start and Stop the clock on
the output buy pressing this button.
Stopping the clock will not send
RST signal. Push and hold this knob
to activate the Performance Time
Stopwatch. See it’s functionality
description below!
Small dot next to the last digit gives
visual indication of clock rate
Adjust shue level from 0 CCW to
extreme 90% CW
This is shue CV input
Random clock generates random
clock pulses, relative frequency of
which is set by BPM. You also can
adjust output pulse duty circle
Here’s shuing clock output. Use
it for more human feel of rhythm.
Shuing clock can be multiplied by
rate set by the encoder. You also can
adjust output pulse duty circle
Use encoder to set BPM manually!
Click the encoder to access the
configuration menu. Refer to the
table below for configuration settings.
Rotate the encoder to select desired
setting. Push the encoder to confirm
it, and return to the main menu. when
all settings are completed push RST
button to exit CONFIG menu OR
module will exit it automatically in 3”
Click and hold the encoder and save
your default device setting!
You also may want to alter an
external clock. When external clock is
applied, LED indicators show external
clock rate
Clock rate is CV controlled – apply
any CV here to alter clock rate! LED
indicators will show BPM set by
encoder and will not follow clock
changes
This is output of the regular clock.
BPM is indicated on LED indicators
Here you get divided or multiplied
clock
BLACK VC CLOCK
Indicator
screen
Setting/configuration
DIV Select clock division or multiplication rate for DIV OUT. Available values are /2, /3, /4, /8, x2, x4, x8
SHD Select clock multiplication rate for SHFL OUT. Available values are x2, x4, x8
RND Select clock division or multiplication rate for RND OUT. Available values are /2, /3, /4, /8, x2, x4, x8
RST Configure RESET feature. The module send reset signal to the sequencer, and it can be sent manually (push RST button any time you wish
to reset the sequencer) or it can send reset signals after certain amount of clock pulses. Available settings are MAN (manual only reset), 16,
32, 48, 64
SHG Adjust clock duty circle for SHFL OUT output pulse. Available settings are from 10 – 90% and random. Default setting is 50%
RNG Adjust clock duty circle for RND OUT output pulse. Available settings are from 10 – 90% and random. Default setting is 50%
PTS Activate or deactivate Performance Time Stopwatch. Performance Time Stopwatch (PTS) allows you to monitor timing of your modular
performances. If PTS is activated, after 5 seconds BPM indicator will change to timer screen that indicates minutes (two digits) passed
from the moment START/STOP button is pushed and module starts to output a clock signal. Pushing START/STOP button will pause the
stopwatch, pushing RST button will reset it.
SAFETY INSTRUCTIONS
DISPOSAL
Please follow the instructions for use of this
Erica Synths module below, ‘cause only this
will guarantee proper operation of the module
and ensure warranty from Erica Synths.
Water is lethal for most of the electric devices,
unless they are made waterproof. Erica
Synths module is NOT intended for use in
a humid or wet environment. No liquids or
other conducting substances must get into
the module. Should this happen, the module
should be disconnected from mains power
immediately, dried, examined and cleaned by
a qualified technician.
Do not expose the module to temperatures
above +50° C or below -20° C.
Transport the instrument with modules
installed carefully, never let it drop or fall over.
Warranty does not apply to modules with
visual damages.
The module has to be shipped in the original
packaging only. Any module shipped to us
for return, exchange and/or warranty repair
has to be in its original packaging. All other
deliveries will be rejected and returned to you.
Make sure you keep the original packaging
and technical documentation.
You will find Erica Synths terms of warranty at
http://ericasynths.lv/en/terms/
Items for return, exchange and/or warranty
repair have to be sent to: Erica Synths,
Andrejostas Str.12, Riga, Latvia, LV-1045
This device complies to the EU guidelines and is
manufactured RoHS conforming without use of
led, mercury, cadmium and chrome.
Nevertheless, this device is special waste and
disposal in household waste is not
recommended.
Designed and made in Latvia.
User manual by Girts Ozolins@Erica Synths.
Design by Baiba Stelle.
Copying, distribution or any commercial use in
any way is prohibited and needs the written
permission by Erica Synths.
Specifications are subject to change without
notice.
In case of any questions feel free to contact us
via e-mail info@ericasynths.lv
Check out other Erica Synths modules & devices
at www.ericasynths.lv
BLACK VC CLOCK

Specyfikacje produktu

Marka: Erica Synths
Kategoria: nieskategoryzowany
Model: Black VC Clock v2

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Erica Synths Black VC Clock v2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Erica Synths

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024