Standard Web Truss Mount
Installation Instructions
Standard Web Truss Mount Installation Guide
April 19, 2017
Tel: (519) 527-2198 Fax: (519) 527-2560
92 Railway St. P.O Box 668
Seaforth, ON Canada N0K 1W0
www.enviranorth.com
- 2 -
Table of Contents
Table of Contents .......................................................................................................................................... 2
I. Before You Begin ............................................................................... 2
II. Tools Required ................................................................................... 2
III. Standard Web Truss Mount Components ....................................... 3
IV. Installation Instructions ..................................................................... 4
Before You Begin
The Standard Web Truss Mount, when installed as directed, is designed and engineered to support up to a 24’
Altra- Air Fan with a 4’ drop and a 4’ extension utilizing a multitude of beam length combinations.
The maximum span achievable across two web truss mounts without the need of additional hardware is 23’
utilizing two 5” x 3.5” x 0.5” angles.
Consult a structural engineer before installation.
WARNING! Ignoring the following instructions can cause physical injury or death, or damage to the
equipment.
NOTE: lustrations/images may be changed without notice. All dimensions and specications are approximate Il
and drawings are not to scale.
Tools Required
Ratchet or impact gun
et to t bolt heads and nuts 7/16” and 3/4” Imperial sock
3/4” Imperial wrench to fit bolt heads and nuts
Lifting device or scaffolding
Appropriate personal protective equipment
Open end torque wrench with torques setting as low as 10 ft/lbs.
- 3 -
Standard Web Truss Mount Components
Web Truss Bracket
EN400X1164
mfd. Flat Bar w/ Welded Nuts
(EN823X8327)
mfd. Flat Bar w/o Nuts
(EN823X8324)
½” Nut (EN823X6306)
Torque to 12 ft/lbs
mfd. I-Beam Clamp
(EN823X8402)
mfd. I-Beam Spacer
(EN823X8401)
½” Nylock Nut (EN823X6301)
Torque to 18 ft/lbs
½” X2½” Hex Head Cap
Screw (EN823X6001)
½” Flat Washer
(EN823X6901)
½” Nylock Nut (EN823X6301)
Torque to 18 ft/lbs
mfd. Bottom Plate
(EN823X8324)
1/8 SS Cable
(EN823X69 ) 52
3/16 Cable Clamp
(EN823X69 ) 52