INDEX
1 SAFETY AND WARNINGS ………………………………………………………………………………2
1.1 Warning …………………………………………………………………………………….……2
1.2 Safety ………………………………………………………………………………….……2
1.3 Warranty …………………………………………………………………………………...……2
2 OPERATING CONDITIONS ……………………………………………………………………..………3
3 INTRODUCTION ……………………………..……………..………………………………………….....4
3.1 General Features . ……..………………...………………………………………………………4
3.2 Applications .……………………………………………………………………………...….5
3.3 MPR-4 Series Products ..…………...………………………………………………………..5
3.4 Overview 5 … …………...…………………………………………………...………………….
3.4.1 Terminals ……..…………………...………………………………………..…………..6
3.4.2 Front Panel …………………………………………………………..……...………..6
3.5 Terminal Structure ...……………..……….………………………………………………..….8
4 INSTALLATION .…….……….……………… ……………………………………………………………9
5 OPERATING INSTRUCTIONS …...…………………………………………………………………….12
5.1 Measurement Screens ………...………………………………………...…..……….……..12
5.1.1. Current, Voltage and Frequency ……………………...………..……...........…….12
5.1.2. Power and Power Factor 4 …… …………………………..…….…………….1……...
5.1.3. Energy and Clock ……………….…………………………...………………………15
5.1.4. THD and Separate Harmonics 8 ……….…….……………...…………………….…1
5.1.5. Minimum, Maximum and Demand Values 9 ……...……...……………..…………..1
5.2 Setup Menu …………………………………………………………………………………23
5.2.1. Device Installation Settings 3 ...…………..…………………….………..……...……2
5.2.2. Display Settings .… ………………………..………………………….…………..…27
5.2.3. Time Settings...…………………...……………………………………………..…28
5.2.4. RS- mmunication Settings485 Co …………………………………………………..30
5.2.5. Input Parameter Settings ..………………………………………………………..31
5.2.6. Output Parameter Settings...........……………………………………….……33
5.2.7. Recording Settings…..…………..……………………………………………..……34
5.2.8. Pulse Input Settings…………………..…….……………………………………..…37
5.2.9. Pulse Output Settings……………………….…………………………………….…38
5.2.10. Operating Hours Settings………………...………………………………..…40
5.2.11. Alarm Settings…….. ………….…..…………………………………………..41…….
5.2.12. Tariff Settings……………………...………………………………………………..44
5.2.13. Reset Settings…………...…………...…………………………………………..45
5.2.14. System Settings…………..…………………………………………………………49
5.2.15. Analog Output Settings……...……….…………………………………………….51
5.3 Reporting Screen …………………………………...………………………….……………54
6 TECHNICAL FEATURES AND APPENDIX ……….………………………………………………….56
6.1 Technical Features ……...……………….……………………………………………………56
MPR-4 SERIES NETWORK ANALYZ ER
USER MANUAL
2
1 SAFETY AND WARNINGS.
Warning
Failure to follow the instructions below may result in serious injury or death.
Cut all power before connecting the device.
Once the device is energized, do not remove the front panel.
Do not attempt to clean the device with a solvent or another similar agent. Use only a dry piece of
cloth.
Check the correct connections before energizing the device.
Contact your authorized seller in case of any problems with your device.
Device is only for panel mounting.
F Type fuse must be used and its current limit must be 1 A.
The manufacturing company is not responsible for the consequences resulting from failure to comply with
these precautions.
Safety
Read the entire user manual before using the device.
A switch or circuit breaker must be connected between the network and the auxiliary supply of
the device.
Connected switch or circuit breaker must be in close proximity to the device.
Connected switch or circuit breaker must be marked as the disconnecting device for the
equipment.
Warranty
Device has a 2 (two) year warranty. Any repairs on the device must be done only by the manufacturer.
Otherwise, the device warranty will be void.
3
2 OPERATING CONDITIONS .
Operating Conditions
Range
Supply Voltage
50 ~ 270 V AC/DC (MPR4X)
24 ~ 60 V AC/DC (MPR4X- D)
Supply Frequency
45 ~ 65 Hz.
Maximum Measuring Current
5,5 A
Maximum Measuring Voltage
480 VAC (VLL)
Operating Temperature
-10 ~ +70 C º
Storing Temperature
-20 ~ +80 C º
Maximum Ambient Humidity
90%
Communication Speed
2400 ~ 115200 bps


Specyfikacje produktu

Marka: ENTES
Kategoria: Sprzęt pomiarowy
Model: MPR-47S-96

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z ENTES MPR-47S-96, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Sprzęt pomiarowy ENTES

ENTES

ENTES MPR-25S-22 Instrukcja

29 Września 2024
ENTES

ENTES MPR-24 Instrukcja

29 Września 2024
ENTES

ENTES EMM-04CS Instrukcja

29 Września 2024
ENTES

ENTES MPR-14S-M3609 Instrukcja

29 Września 2024
ENTES

ENTES MPR-47S-96 Instrukcja

26 Września 2024
ENTES

ENTES EPM-06-96 Instrukcja

26 Września 2024
ENTES

ENTES EVM-3C-48 Instrukcja

26 Września 2024
ENTES

ENTES MPR-45-96 Instrukcja

26 Września 2024

Instrukcje Sprzęt pomiarowy

Najnowsze instrukcje dla Sprzęt pomiarowy

Stamos

Stamos S-LS-28 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-86 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-61 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-81 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-84 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-74 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-76 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-42 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-75 Instrukcja

15 Października 2024
Stamos

Stamos S-LS-35 Instrukcja

15 Października 2024