Instrukcja obsługi ENTES EMR-04SL


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla ENTES EMR-04SL (40 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/40
User Manual
EMR SERIES
NETWORK ANALYZER
2
Index
Introduction ............................................................................................................ 3
Safety and Warnings ........................................................................................ 3
General Specications ..................................................................................... 3
Mechanical and Environmental Conditions ...................................................... 3
Standards 4 .........................................................................................................
Technical Specications ................................................................................... 4
Connection Diagram ......................................................................................... 6
LED Indicator and GUI design .......................................................................... 9
Key Functions ................................................................................................. 9
Measurement......................................................................................................... 10
Voltage 10 .............................................................................................................
Current ............................................................................................................. 11
Frequency ........................................................................................................ 12
Cos Phi ............................................................................................................. 12
Total Cos Phi .................................................................................................... 12
Active Power ................................................................................................. 13
Reactive Power ................................................................................................ 13
Apparent Power ................................................................................................ 14
Energy 14 ..............................................................................................................
Total Harmonic Distortion ................................................................................. 15
Individual Harmonic Distortion .......................................................................... 16
Current Harmonics ........................................................................................... 16
Total Run Hour ................................................................................................. 17
Run Hour .......................................................................................................... 17
Settings.................................................................................................................. 18
User Settings .................................................................................................... 18
Security Settings .............................................................................................. 18
Password Setting ............................................................................................. 19
Connection Settings ......................................................................................... 19
Connection Type .............................................................................................. 20
Frequency 21 ........................................................................................................
Demand Period (Based on Model) ................................................................... 21
Voltage Transformer Setting ............................................................................. 22
Current Transformer Setting ............................................................................. 23
Communication Settings .................................................................................. 23
Output Settings ................................................................................................. 25
Digital Input/Output Settings ............................................................................. 26
User Mode ........................................................................................................ 27
Alarm Settings .................................................................................................. 27
3
Introduction
Safety and Warnings
Caution
Failure to follow the instructions below may result in serious injuries or even death..
Disconnect all power when installing the device.
Do not remove the front panel while the device is connected to the mains.
Do not clean the device with solvent or similar material. Use only a dry cloth.
Check that the connections are correct before operating the device.
Contact your authorized dealer if you have any questions about your device.
The device is for panel mounting only.
The fuse to be used must be type F and the current limit value must be 1A.
The manufacturer cannot be held responsible for unwanted situations that may emerge due to failure
to follow the measures above.
Security
Read the entire operating manual before using the device.
Connect a button or a circuit breaker between supply inlets of the product and the mains.
This button or circuit breaker must be close to the product.
Place a mark to indicate that this button or circuit breaker will be used to separate the product from
the mains.
Warranty
The warranty period of the device is 2 (two) years. In case of a malfunction, the product should be
repaired by the manufacturing company only. Otherwise, the warranty will be void.
General Specications
Wide supply range
Slim design for narrow panels
3-Phase Voltage 3-Phase Current measurement
2 MB Internal Memory
Alarm options (based on model)
Real Time Clock(Model Base)
Run Hour
2x Relay Output (based on model)
2x digital output 2x digital input
Modbus communication (based on model)
96 x 96 panel mounting
Mechanical and Environmental Conditions
Operating Conditions Value Range
Dimensions 96x96
Maximum Depth
(Inside the Panel)
44.5 mm
Installation Panel type
Display LED display
Button 4 x Universal interface
Storage Temperature -30 / +80°C
Operating Temperature -20 / +70°C
Maximum Humidity 95% (noncondensing)


Specyfikacje produktu

Marka: ENTES
Kategoria: Niesklasyfikowane
Model: EMR-04SL

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z ENTES EMR-04SL, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane ENTES

ENTES

ENTES ERB-50 Instrukcja

8 Października 2024
ENTES

ENTES GEM-10SH Instrukcja

8 Października 2024
ENTES

ENTES RGSR-24S-OG Instrukcja

8 Października 2024
ENTES

ENTES RGSR-20S-OG Instrukcja

8 Października 2024
ENTES

ENTES RG3-15CL Instrukcja

8 Października 2024
ENTES

ENTES MPR-53S-96 Instrukcja

8 Października 2024
ENTES

ENTES MPR-47S-L Instrukcja

8 Października 2024
ENTES

ENTES ETMO-02-DR Instrukcja

8 Października 2024
ENTES

ENTES MPR-45S-L Instrukcja

8 Października 2024
ENTES

ENTES MPR-53S-OG-DIN Instrukcja

8 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024