Instrukcja obsługi Enersys ODYSSEY Battery Charger

Enersys Ładowarka baterii ODYSSEY Battery Charger

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Enersys ODYSSEY Battery Charger (14 stron) w kategorii Ładowarka baterii. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/14
US-ODYC-OM-01 Sept 2015
Need Assistance?
Do not return this product to a retailer or dealer for any service or warranty requirements. Please call us
at 1-660-429-2165 from 8:30 am to 5:00 pm Central Time for any technical, warranty or return assistance.
IMPORTANT NOTICE
Please save and read all safety, precautions, warning and operating instructions for the charger and
battery to be charged each time prior to using your ODYSSEY® Battery Portable Charger.
Certifications:
Conforms to UL STD. 1236
Certified to CSA STD. C22.2 No. 107.2
FCC Class A Part 15
CEC Listed
ODYSSEY® Battery 12 Amp Portable Charger OBC-12A 12 12 120VAC +/-10%6’ 9.25” x 11.25” x 3.88”
ODYSSEY® Battery 20 Amp Portable Charger OBC-20A 12 20 120VAC +/-10%6’ 9.25” x 13.75” x 3.88”
Model Part No. Volts Amps AC InCables Size
ODYSSEY® Battery 6 Amp Portable Charger OBC-6A 12 6 120VAC +/-10%6’ 9.25” x 8.75” x 3.88”
www.odysseybattery.com
Energy Saving
Digital Technology
Owner's Manual
RUGGEDIZED WEATHERPROOF CONSTRUCTION
Specifically Designed for 12 Volt Flooded and AGM Lead Acid Batteries. Not for Gel cell (Gelled
Electrolyte Lead Acid) or Lithium Batteries.
4007032
Portable Charger
EnerSys Energy Products Inc.
617 N. Ridgeview Drive
Warrensburg, MO 64093
1-660-429-2165
www.odysseybattery.com
Made in China
WARRANTY
2YEAR
BATTERY CHARGER MEETS FCC CLASS A PART 15
Your battery charger has been designed and tested to comply with FCC Class A Part 15. These regulations
are to provide adequate protection against harmful interference while operated in a commercial
application. If in a residential setting, you are encountering interference with TV and radio reception,
simply remove AC power from the ODYSSEY® battery charger unit to confirm if your battery charger
is causing interference. End user can explore the following to minimize interference.
1) Chose a different AC circuit to power your Portable Battery Charger.
2) Make sure your outlet is properly grounded.
3) Re-position receiving antenna.
4) Purchase a separate AC line filter.
5) Relocate charger so that it is at the furthest point from home receiving equipment,TV, radio, etc.
Model Number Serial Number Date of Purchase
Please Record Your:
Important Charger Operation Note:
Please note the ODYSSEY® Battery Portable Charger Series has a built-in self-test feature
that will look at the battery connections, polarity and battery to determine if the battery
is capable of being charged correctly.
The Self-Test is automatic and will take place every time the unit is plugged into a 110VAC
outlet. The Self-Test may take up to two minutes to complete.
During the Self-Test, the blue Self-Test indicator will be illuminated. If the battery fails the
Self-Test, the charger does not go into the charge mode (red charge mode LED). A red
fault light is illuminated. This will indicate the battery has a problem; poor connection, a
blown DC cable fuse (6 amp ring terminal cable only), the DC cable is wired backwards
or the battery is under 2.5 volts. In any of these cases, refer to the troubleshooting section
on page 21 of this manual.
After the Self-Test has been successfully completed, the charger will register and illuminate
the green “System Check OK” indicator followed by a solid red charge mode LED light
indicating the battery is being charged.
Introduction...................................................................................................1
Important Safety Instructions...................................................................2-3
AC Power Cord Connection..........................................................................4
Personal Precautions....................................................................................5
Preparing to Charge.......................................................................................6
Charger Location...........................................................................................7
DC Connection Precautions - In-Vehicle.......................................................8
DC Connection Precautions - Out-of-Vehicle.................................................9
General Overview.........................................................................................10
Selecting a Charger.....................................................................................11
Product Features........................................................................................12
General Operation..................................................................................13-19
Storage and Maintenance....................................................................................20
Troubleshooting.........................................................................................21
Specifications...............................................................................................22
Product Warranty...................................................................................23-24
Table of Contents
Thank you for your recent purchase of Enersys’ newest line of portable chargers. Our
ruggedized weatherproof portable battery chargers incorporate all-digital microprocessor
control with AC power on self testing, including “System Check OK” and “Battery Fault
Trouble” LED indicators. Our new series also includes a battery charge monitor to show
relative charge status and an energy saving mode that activates after fully charging and
conditioning batteries. This charger will monitor and Auto Maintain batteries only when
needed to maintain a full state of charge, resulting in maximum reserve power performance
and lower AC power consumption and operating costs.
Designed for 12 Volt Flooded and AGM Lead Acid Batteries
ODYSSEY® Battery Next Generation Portable Charger features:
All Digital Technology Microprocessor and software controlled pulse charging technology
delivering a lightweight design, cooler charger operation and faster charging.
LED Battery Charge Monitor Innovative LED Battery Charge Monitor to provide relative
charge level status at a glance during operation.
System OK and Battery Fault Trouble Status Indicator Advanced technology eliminates
time consuming troubleshooting by clearly indicating system and battery connections are
OK or if a fault is present prior to charging a battery.
Six Stage Digital Performance Charging Fully charge and extend the life of your batteries.
- Stage 1: Unit Self Test
Stage 1: Unit Self Test
- Stage 2: Analyzing
Stage 2: Analyzing
- Stage 3: Charging
Stage 3: Charging
- Stage 4: Conditioning
Stage 4: Conditioning
-Stage 5: Auto Maintain
(Energy Saver Mode)
- Stage 6:
Stage 6: Storage Recondition Mode
Digital LED Display Bright LED indicators for all six stages in addition to AC Power On
indication.
Integrated Cable Wrap Body Design Minimize storage space. When not using your portable
charger simply wrap the cables around the body of the charger.
Ruggedized Weatherproof Design Our chargers are design with a rugged extruded aluminum
housing and constructed to take on harsh weather conditions.
Built-in Quality and Safety Spark free connections, built-in over-voltage, overload,
over-temperature and reverse polarity protection.
DC Cable Quick Connector Ring Terminal Cable and Clamps (6 amp model only).
Great for vehicle storage during non use periods.
2-Year Limited Warranty See pages 23 and 24.
Introduction
1
Important Safety Instructions
2
SAVE THESE INSTRUCTIONS
This manual contains important safety and operating instructions for the ODYSSEY®
Battery Portable Charger.
WARNING
To reduce the risk of injury to user or property, the user must read and understand the
instruction manual and all warnings on the charger and battery before use.
WARNING
RISK OF EXPLOSIVE GAS MIXTURE. Read instructions in manual before using charger.
1. Connect and disconnect battery leads only when supply cord is disconnected.
2. For a battery installed in a vehicle, first connect the POSITIVE (RED) Clip of the battery
charger to the POSITIVE (POS,P,+) ungrounded post of the battery. Connect NEGATIVE
(BLACK) clip to vehicle chassis or engine block away from battery. Do not connect clip
to carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy gage metal part
of the frame or engine block.
3. Do not overcharge battery - See Instruction Manual.
4. Do not smoke, strike a match or cause a spark in vicinity of battery.
5. Use in well-ventilated area.
6. Refer to Instruction Manual for further details.
WARNING
This equipment employs parts, such as switches and relays, that tend to produce arcs or sparks
and therefore, if used in a garage, locate in a room or enclosure provided for the purpose or not
less than 18 inches above the floor.
CAUTION
Risk of Electric Shock. Connect only to properly grounded outlets.
Do not expose to rain or snow.
If cords or wires/cables become damaged return complete unit to EnerSys® Energy Products Inc
for service/repair immediately before further use.
CAUTION
1. WARNING - RISK OF EXPLOSIVE GASES.
a. WORKING IN THE VICINITY OF A LEAD ACID BATTERY IS DANGEROUS. BATTERIES
GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS
REASON, IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS
EACH TIME YOU USE THE CHARGER.
b. To reduce risk of battery explosion, follow these instructions and those marked on the
battery. Review cautionary marking on these products and on engine.
2. Use charger for charging a LEAD ACID battery only. It is not intended to supply power to an
extra-low-voltage electrical system or to charge dry-cell batteries. Charging dry-cell batteries
may burst and cause injury to persons and property.
3. NEVER smoke, strike a match or cause a spark or flame in vicinity of battery or engine.
4. NEVER charge a frozen, damaged or leaking battery.
5. If it is necessary to remove battery from vehicle to charge it, always remove grounded terminal
from battery first. Make sure all accessories in the vehicle are off in order to prevent an arc.
6. Study all battery manufacturer’s specific precautions such as removing or not removing cell
caps while charging and recommended rates of charge.


Specyfikacje produktu

Marka: Enersys
Kategoria: Ładowarka baterii
Model: ODYSSEY Battery Charger

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Enersys ODYSSEY Battery Charger, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Ładowarka baterii Enersys

Instrukcje Ładowarka baterii

Najnowsze instrukcje dla Ładowarka baterii

MSW

MSW S-CHARGER-20A.2 Instrukcja

15 Października 2024
MSW

MSW S-CHARGER-10A.2 Instrukcja

15 Października 2024
Intenso

Intenso Powerbank 10400 Instrukcja

14 Października 2024
Gembird

Gembird CHM-03 Instrukcja

10 Października 2024
Kostal

Kostal IQ 8.5 Instrukcja

9 Października 2024
Venom

Venom VS5007 Instrukcja

9 Października 2024
Venom

Venom VS5010 Instrukcja

9 Października 2024
Venom

Venom VS2891 Instrukcja

9 Października 2024
Venom

Venom VS2881 Instrukcja

9 Października 2024
Venom

Venom VS2883 Instrukcja

9 Października 2024