Module to control a relay contact over the
DALI bus (DT7) for DIN top-hat rails DIN-EN
60715 TH35. 98x17,5x56 mm. Protection
class IP20. DALI current consumption 2.7 mA.
Compact relay module for direct control of
230 V loads over DALI. Loads without DALI
input are easily integrated in a DALI circuit.
Loads can be switched on/off by DALI com-
mands. The device function complies with
the standard for DALI Device Type 7 switching
function (as of Firmware 2.0). Adjustable
characteristic for power-up and bus power
failure.
The DALI RM16 is powered over the DALI bus.
No additional power supply is required.
Zero passage switch-on. Integrated power-
on current limit, particularly suitable for
loads with very high power-on current
(> 100 A). The interface represents a bus
user and is therefore addressable.
Conguration via DALI Cockpit PC software.
DALI functions and command set:
The DALI RM16 can integrate loads on the
DALI bus and can then switch them on/off.
The DALI RM16 is a control device for non-
dimmable loads based on the DALI speci-
cations in IEC 62386-208 (Device Type 7).
Accordingly, the switch characteristic is
determined by comparing the virtual dim
level (VDAP) with 4 switching thresholds.
The virtual dim level (VDAP) corresponds to
the dim level of a DALI electronic ballast with
DT7 switching actuator
DL-RM16A-HS-WE
GB
Temperature at mounting location:
-20°C up to +50°C.
Storage temperature: -25°C up to +70°C.
Relative humidity:
annual average value <75%.
33 000 006 - 1
Only skilled electricians may install this
electrical equipment otherwise there is
the risk of re or electric shock!
its corresponding characteristics (limited
by MINLEVEL and MAXLEVEL, dimming
speed limited by fade time and fade rate).
There are 2 switching thresholds in each
dimming direction and they are used for
comparison with the virtual dim level. Only
the applicable switching threshold for the
current virtual dimming direction is evaluated.
A threshold with the value 'MASK' is inactive
and is not used in the comparison.
Switch-on/off delays can be implemented
with fading.
The DALI RM16 is powered from the DALI bus.
The relay response to a bus power failure can
be congured by the SystemFailureLevel
(no change, ON or OFF, factory setting: ON).
The power-on response after applying bus
power can be set with PowerOnLevel.
Technical data
Max. connected current 16 A
Screw terminals:
Max conductor
cross-section 2,5 mm2
Must be kept for later use!
Eltako GmbH
D-70736 Fellbach
Technical Support English:
+49 711 94350025
technical-support@eltako.de
eltako.com
05/2022 Subject to change without notice.
The crossed-out waste container indicates
that batteries may not be disposed with
other household or commercial waste.

Specyfikacje produktu

Marka: Eltako
Kategoria: Niet gecategoriseerd
Model: DL-RM16A-HS-WE

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Eltako DL-RM16A-HS-WE, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niet gecategoriseerd Eltako

Eltako

Eltako FUD61NP-230V Instrukcja

1 Października 2024
Eltako

Eltako FT4F-rw Instrukcja

1 Października 2024
Eltako

Eltako FT4F-wg Instrukcja

1 Października 2024
Eltako

Eltako DSZ15DM-3x80A Instrukcja

1 Października 2024
Eltako

Eltako FTN14 Instrukcja

1 Października 2024
Eltako

Eltako FUD71L Instrukcja

1 Października 2024
Eltako

Eltako FTS14EM T Instrukcja

1 Października 2024
Eltako

Eltako FMZ14 Instrukcja

1 Października 2024
Eltako

Eltako FT4F Instrukcja

1 Października 2024

Instrukcje Niet gecategoriseerd

Najnowsze instrukcje dla Niet gecategoriseerd

TechN

TechN RTX 2080 Instrukcja

1 Października 2024
Morrison

Morrison BL260E S2 Instrukcja

1 Października 2024
DAP-Audio

DAP-Audio EB-193B Instrukcja

1 Października 2024
Hard Head

Hard Head 709-197 Instrukcja

1 Października 2024
Hard Head

Hard Head 349-018 Instrukcja

1 Października 2024
Hard Head

Hard Head 349-019 Instrukcja

1 Października 2024
Hard Head

Hard Head 349-017 Instrukcja

1 Października 2024