Instrukcja obsługi Electrolux EWE361MB-DST1
Electrolux
Kotły i bojlery
EWE361MB-DST1
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Electrolux EWE361MB-DST1 (2 stron) w kategorii Kotły i bojlery. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/2
EN ELECTRIC WATER HEATER USER MANUAL
EWE241MX-DST2
EWE381MX1DST2
EWE451MX-DST2
EWE451MB-DST2
EWE481MX1DST2
1. PARTS IDENTIFICATION (NORMAL SHOWER MODEL)
1. Front Cover
2. Main Display
(*LED Display Main PCB
Board behind front cover)
3. 3 in 1 Stop Valve
i) Stop Valve
ii) Flow Regulator Valve
iii) Built-in-Filter
4. Mesh Filter
5. Rail Support
6. Handshower
7. Adjustable Shower Holder
8. PVC Hose
9. Soap Tray
10. Slider Rail
11. Terminal Block
12. Thermostat (Double-Action)
13. Heater Tank
14. PCB Board (Test & Reset)
15. ELCB Board
16. Water Outlet Connection
17. SMPS PCB Board*
18. DC Pump*
19. Heater Base
20. Triac
21. Flow Sensor
22. Water Inlet Connection
23. Rating Label
24. Test & Reset Button
25. Logo Light
Fig 1. (Thailand, Indonesia, Philippines & Vietnam model)
*
Note : (*) For DC PUMP
*
No Pump model DC Pump model*
19
17
20
18
22
21
14
13
16
19
20
22
21
13
14
16
1
2
5
6
7
8
9
10
11
24 23
2. DESCRIPTION OF LCD DISPLAY AND CONTROL PANEL
1. Earth Icon
2. Power Display Bar
3. Temperature Indicator
4. Memory Indicator
5. Litre for EcoShower
6. rMemo y Button
7. Temperature (-) Button
8. Temperature (+) Button
9. Overheat Icon
10. ELCB Icon
11. Thermistor Icon
12. Low Water Pressure Indicator
13. Cold Shower Icon
14. EcoShower Counter
15. Pump Indicator
16. Cold Shower Button
Notes:
1. Memory includes temperature.
2. Buttons are 100% lit when unit is ON and buttons are not lit when unit is OFF or standby mode.
3. The display and buttons should not blink, unless there is an urgent message/ error/ alarm.
While normal operation all interactions shown without the screen segments blinking.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Fig. 1a
3. SAFETY INFORMATION
3.1 Products manufactured by Elect ux are safe rol
provided they are installed, used and maintained in
instructions and reco dations. Always refer mmen
to this manual if you have any doubt.
WARNING !
3.2 EARTHING :
A) The Eart ng inst lation ld be c ed out in hi al shou arri
acc ance with the al W ng lations.ord loc iri Regu
B) The Electric Water Heater must be earthed.
I er ng such as Earth c uctor not mprop groundi ond
ground ined (float g) or having gh isthi res ance to
grou ound c ld cause malfunction to ELCB and
electrical shock. Never use water heater if t re is he
do hiubt on Eart ng inst lation. al
good working order in accordance with our
3.3 If any of the following conditions occur as
contact the Elect ux Cust er S vice Call Centre. rol om er
Never attempt to ir the unit elf : repa yours
.
.
.
.
.
If the Electric Water Heater begins to make an
odd noise,smell or smoke.
If ELCB trips and LCD display does not light up.
Water temperature cannot be controlled.
If the Electric Water Heater shows signs of a
distinct change in performance.
If water leaks from inside.
s wn below, immediately switch off the mains and ho
3.5 For Pump el, it is ly re Mod high c ed ommend
to c nect the Water Inlet nection to st ge on Con ora
water tank , ot wise it may cause ge to the her dama
built in Pump Motor inside.
3.6 When the Shower is ed by someone such us
as child, derly rson, sick rson and physically el pe pe
han pedicapped rson, the rson concerned is pe
dly rkin equested to pay attention and check the
shower temperature by hand from time to time.
User is advised to test and just the waterad
tem rature bepe fore using.
3.7 During taking shower , once stop for a while
for washing with soap or shampoo and resuming
the shower again by turning on 3 in 1 stop valve
or water tap, it is normal that the instant water
temperature output from the water heater will be
higher than the set temperature.To avoid the risk
of scalding, it is advisable to avoid shower with
water output in that period, or let the water flow
for few seconds before continuing bathing.
3.8 During lightning/thunder, switch off the electric
supply to the shower unit in advance to protect the
shower unit against pos ble damage.si
NOTE : When removing the unit from package,
a small amount of ense water may be f nd cond ou
inside. This is normal as the unit is tested during
3.10 Installation must be carried out by a
quali ed personnel and in compliance local fi
CAUTION !
manufacturing process.
authority regulations.
For the correct size of wire conductor
corresponding to different electrical l gs, oadin
please refer to T le 1. ab
This Electric Water Heater operates
at a minimum water ow rate of 2.0 litre/min fl
and maximum working pressure of 6 bars.
For direct connection from the st ge water ora
tank, the Electric Water Heater must have an
installation minimum ght 1.0m below the hei
st ge water tank. ora
The built-in ELCB ll automat lwi ical y cut
o the er supply in case there is a current ff pow
leakage over 15mA rds.upwa
The thermostat will automatically cut off
the power supply if it has sensed an abnormal
rise in water tem rature. pe
The Electric Water Heater will not
function if there is insuf cient water ow fi fl
(min 2.0 liters/min) to trigger the flow s sor. en
3.12
3.13
3.15
3.16
3.14
his Electric Water Heater must be
permanently ected to the direct main conn line
supply.
B) Recommended to install a er switch for pow
easily to switch ON & OFF the er ly to pow supp
electric water heater before and after use.
C) Hous ld ns switch box must have a eho mai
working ELCB (Incoming ns er smai pow upply)
with RCD es ue ent e) of 10mA.(r id curr devic
3.11 A) T
3.9 WARNING :
A) Metallic / chromed hose and conductive
control valve shall not be used.
B) Must use 3 in 1 Stop Valve accessories
provided with the electric water heater.
5.
ELECTRIC WATER HEATER UNIT INSTALLATION
5.1 Select a suitable position in the bathroom.
5.2 Remove the screw (A) at the bottom of the unit. (Fig. 2)
5.3 Remove the Front Cover by lifting up the front cover from the bottom and be careful not to
over pull
5.4 Mark 3 Screw points of the Heater Base on the wall. The Heater Base position should be
1.5m above the bathroom floor and the left side should be at least 80mm from side wall.
The purpose for user easily to press Test & Reset button by themsleve regularly. (Fig.2)
5.5 Select a suitable position for the Shower Set then mark 4 screws point (2 on top and 2 on
bottom). The gap of 2 screw hole was 38mm. It is recommended that the top of the portion is in
level with the top of Electric Water Heater. (Fig. 3)
5.6 Use 6mm diameter drill and make the wall plug holes in depth of 34mm.
5.7 Insert the wall plugs and mount the Electric Water Heater firmly in position with the screws
provided.
5.8 Insert the Shower Holder and Soap Tray into the Slider Rail.
5.9 Mount the Slider Rail to the Rail Bracket .
5.10 Remove the cap from the Rail Bracket (Fig. 3A) and screw the Bracket to marked
position. Replace the cap. (Fig. 3)
the wire connected between the users interface and main control PCB. Next step is
4. ELECTRICAL LOADING TABLE
Voltage Power Current
(AC) (kW) (A)
220V ~
50/60 Hz
Conductor Size (csa)
mm Conduit Cable Flexible Cable
On/ Off Fuse /
Switch (A) MCB (A)
2.4 10.9 2.5 7 / 0.67mm 50 / 0.25 mm 20 20
3.8 17.3 2.5 7 / 0.67mm 50 / 0.25 mm 32 32
4.5 20.5 2.5 7 / 0.67mm 50 / 0.25 mm 32 32
4.8 21.8 2.5 7 / 0.67mm 50 / 0.25 mm 32 32
TABLE 1
disconnect wire from main PCB.
2
Fig. 3
connect the
hand shower
to flexible hose
*
Washer
connect to
water outlet
connection
ELECTRIC WATER HEATER
UNIT INSTALLATION DIAGRAM
285.5mm
SHOWER SET INSTALLATION DIAGRAM
Flexible Angle
Adjustment
Fig. 2
* Optional For AC/DC Pump
Screw
A
5 Spray
Patterns
Selection
Hand
Shower
Flexible
Hose
Soap Tray
Slider Rail Bar
Adjustable
Shower
Holder
Screw
Wall Plug
Mounting
Terminal
150 mm
connect to
water outlet
connection
3 in 1
stop valve
inlet
connect to
water inlet
connection
Wall
Min.
80 mm
Rail bracket cap
Hexagon tool
(Tighten plastic nut before close cap)
Plastic nut
Fig 3A
RAIL BRACKET COVER & CAP DISMANTLE STEPS
1
RAIL BRACKET
2
OPEN THE RAIL
BRACKET COVER
BY TURNING ANTI
CLOCKWISE &
USING SCREW
DRIVER TO OPEN
THE CAP
3
RAIL BRACKET
COVER COME-OUT
1.
Check the position of the Shower Holder Ring.
this side up
2.
Ensure the Shower Holder Ring are insert correctly.
3.
Adjust to your desired position.
5.
Push it until the Shower Holder Ring are fully
insert to the soap tray.
6.
Adjust the Soap Tray until it fit nicely on the
Shower Holder Ring .
4.
The gap of Shower Holder Ring must faced
inside the hook of the Soap Tray .
gap
Method of install the soap tray (straight bar type)
8.
ELECTRICAL INSTALLATION
8.2 Remember to SWITCH OFF the
mains before carrying out any electrical
work.
8.3 Refer to TABLE 1 for the correct
cable size.
8.4 Use double insulation cable of over
2.5mm² for 2.4kW, 3.8kW, 4.5kW,
4.8kW models and 4.0mm² for 3.6.kW.
WARNING! PROCEDURE :
8.6 Insert the ll ed le t wa embedd cab hrough
Side Entry ‘A’ by cutting a le at the urce ho so
co rubb holdrd er er and ad the c le to le le ab Cab
Bracket ‘B’. (Fig. 6)
Fig. 6a
8.1 EARTHING :
A) The Eart ng inst lation shi al hould be
c ed out in acc ance with the local arri ord
W ng lat ns.iri Regu io
B) The Electric Water Heater must be
earthed. I er ng such as Earth mprop groundi
c ductor not on ground ined (float g) or having
high resistance to nd c ld cause grou ou
malfunction to ELCB and electrical shock.
Never use water heater if t re is ubt on he do
Eart ng insthi allation.
8.5 Lead the power cable from MCB to a
“ON/OFF’’double pole Linked Switch having
a contact separation of at least 3mm in all
poles outside the bathroom, then lead a
cable to the terminal block inside the Electric
Water Heater Unit. (Fig. 4)
Note: Refer to No. 3 Safety Information
before Plumbing and Electrical Installation
for safety and warning details.
NOTE:
Refer to TABLE 1 for electrical loading and
correct size of wire conductor
Fuse Distributor Board
Miniature Circuit Breaker (MCB)
ON/OFF Double Pole Switch
Double PVC cable
Cable
Brown or Red = Live (L)
Blue or Black = Neutral (N)
Green or Green/ Yellow = Earth ( )
Fig. 4
Fig. 5
8.8 ect the LCD ay c le from front Conn displ ab
cov Maer to the in Control PCB. Cla abmp the c le
to the rrect position. co CHEC TH WIRING K IF E
CONNECTION S CORRECT and ce the I repla
cover. (Fig. 6a)
8.7 nect the c le as f ng: (Fig. 5)Con ab ollowi
BROWN or RED --L E (L)IV
BLUE or BLACK --NEUTRAL (N)
GREEN or GREEN/YELL --EARTH ( )OW
s
L
N
L
N
Ground
ELCB 15mA
s
L
N
L
N
Ground
ELCB 15mA
s
L
N
L
N
Ground
ELCB 15mA
Fig. A correct wiring connection
Fig. B wrong wiring connection (neutral and
earth reversed)
Fig. C wrong wiring connection (live connected
to neutral , neutral connected to earth)
8.9 Ex le of amp wro wiri onnng ng c ection to the
Electric Water Heater
Min.
80 mm
REV 0
A
Fig. 6
B
3
4
3
4
3
4
11
12 12
15 15
*For Pump Model only
3.4 If the Red (POWER) Indicator does not go off
when you turn off the water, switch OFF the
mains supply and contact Electrolux Consumer
Care Centre for repair service.Special skill is
required for repairing.
NEVER try to repair the unit by yourself.
RAIL BRACKET COVER & CAP DISMANTLE STEPS
6.
RAIN SHOWER SET INSTALLATION PROCEDURES (MALAYSIA ONLY)
RAIL BRACKET OPEN THE RAIL
BRACKET COVER
BY TURNING ANTI
CLOCKWISE & USING
SCREW DRIVER TO
OPEN THE CAP
RAIL BRACKET
COVER COME-OUT
shower holder
top rail bracket
slider rail
selector valve
1. 2.
STEP 1
Insert the Top Rail Bracket, Adjustable Shower Holder,
Soap Tray & Bottom Rail Bracket to the Slider Rail.
STEP 2
Connect the Selector Valve to the bottom of Slider
Rail.
soap tray
1
2
3
slider rail
soap tray holder
soap tray
Fig. 3B
For Soap Tray
- Insert Soap Tray Holder into Soap Tray
hole. (Fig. 3B)
- Then insert soap tray (with Soap Tray Holder)
into Slider Rail.
- Soap Tray shall be insert to the Slider Rail
after Shower Holder.
Fig. 3A
bottom rail bracket
38mm
38mm
1300mm 650mm
wall plug hole screw
mounting terminal
3.
4.
Select a suitable position for the Rain Shower Set
then mark 4 screws point (2 on top and 2 on bottom).
The gap of 2 screw hole was 38mm. It is
recommended that the Top Rail Bracket position at
height of 1950mm to the floor and Bottom Rail
Bracket 1300mm to the floor.
wall plug
STEP 4
Use 6mm diameter drill and make the wall plug
holes in depth of 34mm. Insert the wall plugs and
mounting terminal firmly in position with the screw
provided.
STEP 3
rail
bracket cap
hexagon tool
plastic nut
STEP 5
Mount the Slider Rail (connected with Rail Bracket,
Adjustable Shower Holder and Selector Valve)
to the mounting terminal by turns the terminal cover.
5. 6.
STEP 6
Remove the cover and cap from the Rail Bracket
(Fig. 3A) and screw the rail bracket by turning the cover
clockwise. Using hexagon tool to tighten the plastic nut
to the desire position and then replace the cover.
rail bracket
cover
1200mm
650mm
100mm
PVC hose
rain
shower
head
shower
head
7. 8.
STEP 7
Connect the Rain Shower Head to the top of Slider
Rail, 1.5Meter PVC Hose to Hand Shower Head and
1Meter PVC Hose to the Heater. Connected be sure
to put in the Rubber Washer.
STEP 8
Recommended Height for Rain Shower Set.
rubber
washer
a
b
c
d
7. PLUMBING PROCEDURE
CAUTION ! IMPORTANT !
WARNING !
This Electric Water Heater is a single point system
and the “Water Outlet” can only be fitted to the
PVC Hose and Handshower set provided.
CONTROL VALVE OR FITTING CANNOT BE
ALLOWED FITTING TO THE WATER OUTLET.
7.1 Connect the 3 in 1 Stop Valve to the Water
Inlet connect with washer. Use correct tools to
tighten and be careful not to over tighten and
damage the plastic nut.
7.2 Connect the incoming water piping to the
3 in 1 Stop Valve (1/2” BSP). Make sure to put
the Mesh Filter between
3 in 1 Stop Valve and incoming water piping.
7.3
Turn on the water mains to drain out all
plumbing dirts, at the same time fill up the
heater tank before connect shower head.
7.4 Connect the shower head to the hose.
(rain shower installation procedure step 7)
(Be sure to put in the Washer.)
7.6 THE HEATER TANK MUST BE FILLED UP
WITH WATER BEFORE TURNING ON THE
ELECTRICITY SUPPLY TO PREVENT ANY DRY
BURNT DAMAGE TO THE HEATING ELEMENT.
7.7 Hook the Handshower to the Slider Rail
Shower Holder and adjust to your ideal position.
7.8 Check if any water leakage.
7.9 Do not use white tape during piping installation.
7.10 THE WATER INLET AND OUTLET MUST BE
INSTALLED IN CORRECT DIRECTION,
OTHERWISE HEATER UNIT WILL NOT FUNCTION.
7.11 DO NOT APPLY PLUMBING CEMENT ON
CONNECTION. WHENEVER NECESSARY, USE
ONLY THREAD OR SEALING TAPE AT 3 IN 1
STOP VALVE INLET ONLY. (FIG 2)
7.12 Must use 3 in 1 Stop Valve accessories
provided with the electric water heater.
For Pump Model, it is highly recommended to
connect Water Inlet Connection to storage
supply tank , otherwise it may cause damage to
the Pump Motor.
7.5 Connect the Hose to the water outlet.
(rain shower installation procedure step 7)
(Be sure to put in the Washer.)
25
1. PARTS IDENTIFICATION (RAIN SHOWER MODEL)
1. Front Cover
2. Main Display
(*LED Display Main PCB
Board behind front cover)
3. 3 in 1 Stop Valve
i) Stop Valve
ii) Flow Regulator Valve
iii) Built-in-Filter
4. Mesh Filter
5. Rail Support
6. Handshower
7. Adjustable Shower Holder
8. PVC Hose
9. Soap Tray
10. Slider Rail
11. Terminal Block
12. Thermostat (Double-Action)
13. Heater Tank
14. PCB Board (Test & Reset)
15. ELCB Board
16. Water Outlet Connection
17. SMPS PCB Board*
18. DC Pump*
19. Heater Base
20. Triac
21. Flow Sensor
22. Water Inlet Connection
23. Rating Label
24. Rain Shower Head
25. AC Pump*
26. Test & Reset Button
27. Logo Light
Fig 1a. (Malaysia only)
*
*
AC Pump Model* DC Pump Model*
19
17
20
18
22
21
14
15
16
19
20
22
21
13
14
16
1
2
5
6
7
8
9
10
11
26 23
3
4
3
4
11
12 12
3
4
8
25
15
*For Pump Model only
24
13
*
EWE361MB-DST1
EWE361MA-DST1
27
NORMAL SHOWER INSTALLATION
(
Thailand, Indonesia, Philippines & Vietnam model
)
(THAILAND, INDONESIA, PHILLIPINES & VIETNAM MODELS)
3.6 15.0 4.0 7 / 0.85mm 56 / 0.30 mm 32 32
240V ~
50/60 Hz
(Malaysia
model only)
9.2 MANUALLY CHANGE TEMPERATURE
(i)
(ii)
(iii) (iv)
Press (+) button
- ee goes up. Degr
- P er display bar level c ges ow han
acc gly to reach the des ed ordin ir
t rature.empe
Press and hold (+) button for 2 sec
- T rature gits rises at faster s ed empe di pe
up to the max um 45 ee.im degr
- P er display bar just acc ly. ow ad ording
- If actual t rature c not reach the SET empe an
t rature, the “MAX” ll ow & empe wi sh blink. If
the actual t rature reaches SET t ratureempe empe
, “MAX” ll dis ar.wi appe
- ee es wn. Degr go do
- P er display bar level cow hanges
acc gly to reach the des ed ordin ir
t raturempe e.
- T rature gits falls at faster sempe di pe doed wn to 32
ee and stop autosc ll.degr ro
- P er lay bar just acc gly.ow disp ad ordin
- If the setting reached 32 degree, presses DOWN
button one re time ll t er the cold water function.mo wi rigg
The temperature can be gradually controlled by pressing either UP or DOWN button: -
Notes: The ry icator ll ar in the ent that the al ection for the t rature memo ind wi appe ev manu sel empe
and/or mp (*) v ue nation ch is same as st ed ry, the ry icator ll ghts up.pu al combi whi or memo memo ind wi li
Press (-) button Press and hold DOWN button for 2 sec
9. TEST OPERATION
9.1 TEST RUN
- The icons ll ink 2 times arth, wi bl (e
overheating, electrical leak and
t mistor) after switch ON.her
(i)
(ii)
(iii)
when the 3 in 1 stop valve is turns on
SafeReady
- Last used setting ll be activate if the wi
3 in 1 stop valve is turns on.
Before switch ON electricity supply, please check the electrical wiring connection properly to the
Electric Water Heater : -
- When 3 in 1 stop valve is turns off,
Electric Water Heater goes to
pre-standby.
- If the 3 in 1 stop valve not ON, after 5
minutes will go to standby mode. (50% light dimmer,
after 15 minutes, the light will turn off)
(iv)
9.3 COLD SHOWER SHORTCUT
Water heater is running
- User presses the cold s er how
button.
- After Pressed display c ed hang
to 8.3 i). (i
(i)
(ii)
- Electric Water Heater turn off the heating element.
- Temperature digits changes to two lines.
- The cold setting ( ) icon lights up on the display.
Cold shower function can be activate via shortcut button: -
Cold setting activated
9. TEST OPERATION
(CONT’D)
(iii) (iv)
- Presses the cold shower button
then display will go back to
previous setting.
Cold setting deactivated Cold setting deactivated (Alternative)
- Pressing the M1/ M2/ M3 will go to memory setting.
- Pressing up button will adjust setting temperature.
- Pressing down button will not affect cold setting.
9.4 FOR PUMP MODEL
The pump will ON when the Power supply on and 3 in 1 Stop Valve opened.
N otes: 1. If actual t rature c not reach the set t rature, full er bar ll be s wn and empe an empe pow wi ho
‘MAX’ dis ay ll ink.pl wi bl
It ght due to flow rate too gh or inc ng water t rature too low. mi hi omi empe
Adjust the 3 in 1 stop valve to uce water flow.red
2. It is ed not to rate the mp for re than 30 nutes. recommend ope pu mo mi
(iii) (iv)
- Press any button except your c ent urr
s ected ory (1, 2 & 3) and el mem
EcoS er button to exit your selected how
ory.mem
Deactivate the memory function - The ory dicator ll ar in mem in wi appe
the event that the selecte d t ratureempe
v ue are the same as st ed ory, al or mem
the ory icator ll ghts up.mem ind wi li
9.5 MEMORY SETTING
Memory function
- P ss M button for 3 sec ds, ry 1, 2re on Memo
d 3 l r.an wil appea
- P ss M button to s ct the y r,re ele memor numbe
s ected ry r l k.el memo numbe wil blin
- P ss the T at e (+) or ) to c ose re emper ur (- ho
des e t at e d ave for 3 sec ds.ir emper ur an le on
- Once p to ate the sett g has n bee indic in bee
st d.ore
(i)
(ii)
This Electric Water Heater allows user to store up to 3 desired settings (M1/ M2/ M3) for easy access: -
Memory selection
- User may selects a des ed stir ored setting
by pressing M button.
9.6 ELCB TESTING
This procedure is highly recommended to test at least once a month:-
Press TEST button
- The E1 ay ink & ep 3 times displ bl be
and auto turn OFF.
(i)
a) ELCB ok: -
Press TEST/ RESET button
- The E4 ay ink & ep 3 times displ bl be
and auto cut off, c not be set and an re
ease contact Elect lux cust er pl ro om
rvice call centre.se
(i)
b) ELCB failure: -
(ii)
Press RESET button
- The Electric Water Heater recover, the
icons arth, ov eating, electrical leak (e erh
and t mistor) ll ink 2 times & back to her wi bl
evious display. pr
ELCB TEST/RESET BUTTON
9.8 ECOSHOWER OPERATION
Normal usage
(i)
- al display en 3 in 1 Norm wh
stop valve ng turns on. bei
EcoShower is to calculate water consumption by bucket (1 bucket = 20 Liters) and have Eco friendly
environment benefits for user notification of water consumption on each shower. EcoShower will start activate
whenever 3 in 1 stop valve being turns on.
9.7 LOW WATER PRESSURE
(i)
(ii)
Low water pressure
- Low water pressure dicator ll be in wi
ed on sc en en water pressure appear re wh
is er than activation flow rate. low
ow water essure dicator ll be (L pr in wi
occas al dis ed if water pressure is ion appear
too low ow 0.8 Litre/min, the display ll bel wi
be me to the e-st dby sc en and beco pr an re
we can not activate any button on the display
of Electric Water Heater).
- Pump button ways ghts up if the al li 3 in 1
stop valve en ng e-st dby de op duri pr an mo
(For el with mp function only). mod pu
- ng the st dby de, en turn on the Duri an mo wh
3 in 1 stop valve, if the water flow rate still
c not activate the Electric Water Heater, the an
low pressure dicator ll be ed.in wi appear
Activate pump function
- To increase the water pressure, user presses and
ld the ( ) button for few sec ds.ho on
- Pump activate at full s ed and flow rate ll be pe wi
increased.
- Low water pressure dicator ll be dis ed in wi appear
and the Electric Water Heater ll work lly if wi norma
the flow rate can be intain er than the ma high
activation flow rate.
- If the Electric Water Heater still be not le to intain ab ma
the flow rate above the activation flow rate and the Low
water pressure dicator still ar, user may eat in appe rep
the above step by presses and ld (ho ) button.
(It is not rec ed to eat the step re than ommend rep mo
3 times if the water pressure still be not st le and ab
c not intain above activation flow rate).an ma
- It is not rec ed to rate the mp for re ommend ope pu mo
than 30 nutes. mi
This Electric Water Heater can start and function at minimum rated flow rate . :-
(iii) (iv)
- The EcoS er ration cont ues.how ope in
- The EcoS er bucket counter ll how wi
acsent 1 bucket each time the
EcoS er liters counter reach 20 liters. how
- The EcoS er liters counter ll be reset how wi
to 0 each time en ch 20 liters. wh rea
(Present display 1 bucket & 0 liters
ng to 20 liters water consumption)meani
- Turn off the 3 in 1 stop valve the display es go
into -st dby.pre an
- If the user cont ue s er within in how 15 nutes mi
from previous section, the counter ll cont ues. wi in
(Present display 3 bucket & 5 liters ng to 65 meani
liters water consumption)
10.
HANDSHOWER SPRAY
This Innovative adjustable Handshower has 5 different spray patterns (STANDARD, JUMBO, SOOTHE,
MIX and MASSAGE. The patterns are described as following:
Fig. 7
STANDARD SPRAY SOOTHE SPRAY JUMBO SPRAY MIX SPRAY MASSAGE SPRAY
Move the Handshower to the desired angle. A ratchet mechanism in the Shower Holder will hold the
Handshower in selected position. (Fig. 8)
Holder
Knob
Fig. 8
11. MAINTENANCE
10.1 TEST THE ‘ELCB’ REGULARLY
(This procedure is highly recommended test
at least once a month)
Turn on the electricity and water supply, LCD
display will lights up after self checking.
Press the ELCB Test Button, Electric Water
Heater should go off. Press the Reset Button
to resume the electricity supply.
(Refer to 8.6)
10.2 CLEAN THE FILTER REGULARLY
Clean the Mesh Filter regularly to prevent
blockage. (Fig. 9) Remove the Built-in Filter
by turning its cap anticlockwise. Whenever
need flush the internal stainer with water to
remove any trapped sediments. (Fig. 10)
Whenever fixing back the Built-In Filter,
beware of the alignment of Internal Strainer.
Use the protruded guideline within 3 in 1
Stop Valve to position the Internal Strainer.
Read the section ‘ 3. SAFETY INFORMATION ’ first.
WARNING !
10.3 If the Electric Water Heater does not
go off when you press the ELCB Test Button,
switch OFF the mains supply and contact
Electrolux Customer Service Call Centre for
repair service. Special skill is required for
repairing. NEVER try to repair the unit by
yourself.
10.4 CLEANING PRECAUTION !
Do not use thinner,alcohol,petrol or any other
organic solutions to clean the set. Use only
damped cloth with mild detergent.
Fig. 10
FILTER UNIT CLEANING
12. TROUBLESHOOTING
Problem/Symptom Cause Action/Cure
Electric Water Heater
fail to rate, no ope
power.
Int upted err pow super ply.
Electric Water Heater
malfunction.
Water too hot. Not gh water f ingenou low
t gh the s er.hrou how
Blockage in water ply.sup
Inc ng water omi
t rature too gh.empe hi
Water too cool or cold. Too much water flow.
Water pressure lowbe
minimum ed andrequir
water heater not function.
Inc ng water omi
t rature too low.empe
Electrical malfunction of
Electric Water Heater.
Safety T mostat cher ut-out
operated.
Check the re c nection and in werwi on ma po
s ply f it still fail to up . I operate, contact
Elect lux Custro omer Service ll Centre.Ca
Check other ances are having same appli
phenomenal and contact cal Electricity lo
S ly any. Let the Electric Water upp Comp
Heater checked f it still fail to rate, . I ope
contact Electrolux Customer Service Call
Centre.
I ease flow rate via water flow cont lerncr ro
or 3 in 1 Stop v ve.al
Blocked of s er ad - c an how he le or lace.rep
Check if 3 in 1 stop v ve are fully turns on.al
Cleaning sh Filter and Built In Filter. Me
(Refer to 10.2)
Reduce the setting t rature viaempe
t rature uster. (Up , wn button)empe adj do
Reduce flow rate via water flow cont er rol
or 3 in 1 Stop v ve.al
Check water supply from ins or tank fed? ma
If tank fed, mb to ins water s ply replu ma up
and check if the water pressure is gh.enou
If mains fed, make sure that mains
3 in 1 stop valve is fully turns on and that
t re are no other restrictions in the water he
s ly le water heater is in use. upp whi
I ease the setting t rature viancr empe
t rature uster or 3 in 1 Stop valve.empe adj
Contact Electrolux Cust er Service ll om Ca
Centre.
Safety T mostat cut-out rated. her ope
Contact Electrolux Customer Service Call
Centre.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Water flow too low.
3 in 1 Stop Valve Filter /
Mesh Filter ocked.bl
Clean the filter (refer 10.2).
-
3 in 1 Stop Valve not
fully open.
-Open 3 in 1 Stop Valve to re flow rate.desi
Water s ply insufficent.up - Check house water ly.supp
Water hot after close
and en of 3 in 1 reop
Stop Valve or Water
Tap.
Water t rature herempe hig
than set temperature when
3 in 1 Stop Valve or Water
Tap is OFF a le and whi
reopen in.aga
Avoid s er with water output in that how
period.
-
Let the water flow few seconds before
cont ue bat ng. in hi
-
12. TROUBLESHOOTING (CONT’D)
Notes:
* It is advised all electrical int ance/ rs to the s er s ld be cma en repai how hou arried out by
a suitably lified person. qua
* In the unlikely event of Electric Water Heater f re other than detailu ailed in the fault findi pang ge,
please contact Elect ux Cust er Service ll Centre for advice.rol om Ca
Problem/Symptom Cause Action/Cure
Electrical leak can be
t ed at any time in rigger Contact Electrolux Cust er S ce Callom ervi
Centre.
If the Electric Water Heater is
not earthed ly, the earth proper
icon ll wi appear on sc en re
during usage or st dby.an
The E2 and t mistor iconher
will ar and nk on sc en appe bli re
in sync nisation with the hro
beep due to t istor E or. herm rr
E4 ll wi blink in synchronisation
with the beeps 3 times if the
Its rec ed er must have er omend us prop
earth c ected to water heater.onn
Contact Electrolux Cust er Service Callom
Centre.
The on nk until t ratureic bli empe
drop then return to malnor
funct lity. iona
In the re case, the on ra ic does not return
to al funct lity (safety t ostat norm iona herm
cut
-out rated), Contact Electope rolux
Cust er S ce ll Centre.om ervi Ca
Contact Electrolux Cust er S ce Callom ervi
Centre.
Display a arppe E1 with
Display a ar Ear Iconppe th
Display a arppe E2 and
Th rm store i Icon
Display a ar ppe
o h t iconver ea
Display a r E4ppea
-
-
-
-
-
-
Earth icon also appear if Live
& Neutral reverse c ectiononn
-Connect ve / Neutral ectly.Li corr-
The heater ll be stops wi
working and shows the
ov eat icon nking and erh bli
beep 3 times if the t rature empe
meas ed is ur above 55 degrees.
-
13.WIRING DIAGRAM
WIRING DIAGRAM-DPDT*MODEL (NO PUMP/AC PUMP)
T2
G
LIVE
NEUTRAL
TRIAC
Nout
(N
in )
(L
in )
Main Supply
220/230/240 V~a.c.
MAIN CONTROL BOARD
TOUCH SCREEN
Electronic
ELCB,15mA
Sensit ivity
Reset
Test
FLOW SENSOR ASSY.
Lout
Auto -Reset * Ma nual-Reset
Double Act ion Thermost at
E
EARTH
(*) For PUMP Model
AC PUMP
(*) For PUMP Model
* Manual Reset (90°C Thermostat)
For Models rated 4.8kW and below, thermostat is manually resetable.
For models rated 6.0kW and above, thermostat needed to be replaced
once permanently tripped.
* DPDT : Double Pole Double Action Thermostat
WIRING DIAGRAM-DPDT*MODEL (FOR VIETNAM MODELS ONLY) (DC PUMP)
T2
G
LIVE
NEUTRAL
TRIAC
Nout
(N
in
)
(L
in
)
Main Supply
220/230/240 V~a.c.
Electronic
ELCB, 15mA
Sensitivity
Reset
Test
FLOW SENSOR ASSY.
Lout
Double Action Thermost at
E
EARTH
(*) For PUMP Model
Heating Element A
Heating Element B
Auto-Re set * Manual-Reset
Relay 1
Relay 2
Relay 3
MAIN CONTROL BOARD
TOUCH SCREEN
SMPS PCB
ASSY
Silent Pump
14.
ELECTRICAL SPECIFICATION
Note : The specification, actual product’s cosmetic design and accessories parts shown are
correct at the time of printing and may be subjected to change without prior notice.
3.5 kg - ELCB , DPDT, NO PUMP
4.6 kg - ELCB , DPDT, AC PUMP
3.8 kg - ELCB , DPDT, DC PUMP
2 Litre / min
6.0 Bar (0.6 MPa ; 87.02 psi)
ELECTRONIC POWER CONTROL
TYPE
ELECTRICAL LOADING
Min. WATER FLOW RATE
Max. INLET WATER PRESSURE
WATER CONNECTION
DIMENSIONS
GROSS WEIGHT
2.4kW 220V a.c. 10.9A 50Hz and 60Hz
3.8kW 220V a.c. 17.3A 50Hz and 60Hz
4.5kW 220V a.c. 20.5A 50Hz and 60Hz
4.8kW 220V a.c. 21.8A 50Hz and 60Hz
1/2” BSP SINGLE POINT SYSTEM
220 (W) X 401 (H) X 80 (T) mm
Min. INLET WATER PRESSURE
0.1 Bar (10 kPa ; 1.45 psi)
CONSUMER CARE
Indonesia
Hotline service: 08041119999
PT. Electrolux Indonesia
Electrolux Building
Jl.Abdul Muis No.34, Petojo Selatan,
Gambir Jakarta Pusat 10160
Email:customercare@electrolux.co.id
SMS & WA : 0812.8088.8863
Malaysia
Consumer Care Center Tel: 1300-88-11-22
Electrolux Home Appliances Sdn. Bhd.
Corporate Office Address: Unit T2-7, 7th Floor, Tower 2 ,
Jaya33 Hyperoffice, No. 3, J alan Semangat, Seksyen 13,
46100 Petaling Jaya, Selangor
Office Tel : (+60 3) 7843 5999
Office Fax : (+60 3) 7955 5511
Consumer Care Center Address: Lot C6, No. 28,
Jalan 15/22, Taman Perindustrain Tiong Nam,
40200 Shah Alam, Selangor
Consumer Care Center Fax : (+60 3) 5524 2521
Email : malaysia.customercare@electrolux.com
Philippines
Consumer Care Center Toll Free : 1-800-10-845-CARE 227
Cons umer Care Hotline : (+63 2) 845 CARE 2273
Electrolux Philippines, Inc.
10th Floor. W5th Avenue Building
5th Avenue Corner 32nd Street
Bonifacio Global City,
Taguig Philippines 1634
Trunkline: +63 2 737- 4756
Website : www.electrolux.com.ph
Email : wecare@electrolux.com
Singapore
Consumer Care Center Tel: (+65) 6727 3699
Electrolux S.E.A. Pte Ltd.
1 Fusionopolis Place,
#07-10 Galaxis, West Lobby
Singapore 138522.
Office Fax : (+65) 6727 3611
Email : customer-care.sin@electrolux.com
Thailand
Consumer Care Tel : (+66 2) 725 9000
Electrolux Thailand Co., Ltd.
Electrolux Building 14th Floor
1910 New Phetchaburi Road,
Bangkapi, Huai Khwang, Bangkok 10310
Office Tel : (+66 2) 7259100
Office Fax : (+66 2) 7259299
Email : customercarethai@electrolux.com
Vietnam
Consumer Care Center Toll Free : 1800-58-88-99
Tel : (+84 8) 3910 5465
Electrolux Vietnam Ltd.
Floor 9th, A&B Tower
76 Le Lai street - Ben Thanh Ward - District 1
Ho Chi Minh City ,Vietnam
Office Tel : (+84 8) 3910 5465
Office Fax : (+84 8) 3910 5470
Email : vncare@electrolux.com
Hongkong
Tel: (+852) 8203 0298
Dah Chong Hong, Ltd. - Service Centre
8/F., Yee Lim Godown Block C
2-28 Kwai Lok Street, Kwai Chung, N.T.
Fig. 9
CLOSE
OPEN
INTERNAL
STRAINER
OPEN CLOSE
FLOW REGULATOR
MESH FILTER
BUILT-IN FILTER
WE’RE THINKING OF YOU
Thank you for purchasing an Electrolux appliance. You’ve chosen a product that brings with
it decades of professional experience and innovation. In genious and stylish, it has been
designed with you in mind. So whenever you use it, you can be safe in knowledge that
you’ll get great results every time. Welcome to Electrolux.
Visit our website to:
Get usage advice, brochures, trouble shooter, service information:
www.electrolux.com
Register your product for better service:
www.registerelectrolux.com
Buy Accessories, Consumables and Original spare parts for your appliance:
www.electrolux.com/shop
CONSUMER CARE AND SERVICE
We recommend the use of original spare parts.
When contacting Service, ensure that you have the following data available.
The information can be found on the rating plate. Model, PNC, Serial Number.
(Right side of unit).
Warning/ Caution-Safety information.
General information and tips.
Environmental information.
Subject to change without notice.
- If the user did not shower more than 15 minutes,
the counter will reset to zero.
synchronisation with the
beeps 3 times during usage
or standy.
ELCB have problem during
ELCB test.
3.6kW 240V a.c. 15.0A 50Hz and 60Hz
WIRING DIAGRAM-DPDT*MODEL (DC PUMP)
T2
G
LIVE
NEUTRAL
TRIAC
Nout
(N
in
)
(L
in
)
Main Supply
220/230/240 V~a.c.
MAIN CONTROL BOARD
TOUCH SCREEN
Electronic
ELCB,15mA
Sensitivity
Reset
Test
FLOW SENSOR ASSY.
Lout
Auto- Reset * Manual-Reset
Double Action Thermostat
E
EARTH
SMPS PCB
ASSY
Silent Pump
Specyfikacje produktu
Marka: | Electrolux |
Kategoria: | Kotły i bojlery |
Model: | EWE361MB-DST1 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Electrolux EWE361MB-DST1, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Kotły i bojlery Electrolux
30 Września 2024
29 Września 2024
29 Września 2024
29 Września 2024
29 Września 2024
29 Września 2024
29 Września 2024
5 Lipca 2024
4 Lipca 2024
2 Lipca 2024
Instrukcje Kotły i bojlery
- Kotły i bojlery Tesy
- Kotły i bojlery AEG
- Kotły i bojlery Teka
- Kotły i bojlery Gorenje
- Kotły i bojlery LERAN
- Kotły i bojlery Philips
- Kotły i bojlery Morco
- Kotły i bojlery Dometic
- Kotły i bojlery Bosch
- Kotły i bojlery Whirlpool
- Kotły i bojlery Ferroli
- Kotły i bojlery Midea
- Kotły i bojlery Hisense
- Kotły i bojlery Infiniton
- Kotły i bojlery Panasonic
- Kotły i bojlery Rinnai
- Kotły i bojlery GE
- Kotły i bojlery Taurus
- Kotły i bojlery Orbegozo
- Kotły i bojlery Siemens
- Kotły i bojlery Haier
- Kotły i bojlery Jocel
- Kotły i bojlery Remeha
- Kotły i bojlery Truma
- Kotły i bojlery CATA
- Kotły i bojlery Hotpoint
- Kotły i bojlery Ariston Thermo
- Kotły i bojlery Intergas
- Kotły i bojlery Daikin
- Kotły i bojlery Kospel
- Kotły i bojlery Buderus
- Kotły i bojlery Corbero
- Kotły i bojlery Viessmann
- Kotły i bojlery Fagor
- Kotły i bojlery Vaillant
- Kotły i bojlery Eta
- Kotły i bojlery HTW
- Kotły i bojlery Dimplex
- Kotły i bojlery Baxi
- Kotły i bojlery Arçelik
- Kotły i bojlery Worcester
- Kotły i bojlery Atag
- Kotły i bojlery Rommer
- Kotły i bojlery Inventum
- Kotły i bojlery SVAN
- Kotły i bojlery Solac
- Kotły i bojlery Mora
- Kotły i bojlery VOX
- Kotły i bojlery Junkers
- Kotły i bojlery ACV
- Kotły i bojlery Aspes
- Kotły i bojlery Hitachi
- Kotły i bojlery Respekta
- Kotły i bojlery Technika
- Kotły i bojlery Quantum
- Kotły i bojlery Kelvinator
- Kotły i bojlery Sencor
- Kotły i bojlery Kunft
- Kotły i bojlery De Dietrich
- Kotły i bojlery Nefit
- Kotły i bojlery A.O. Smith
- Kotły i bojlery Stiebel Eltron
- Kotły i bojlery Elco
- Kotły i bojlery Masterwatt
- Kotły i bojlery Nibe
- Kotły i bojlery Elba
- Kotły i bojlery Buffalo
- Kotły i bojlery TTulpe
- Kotły i bojlery Atlantic
- Kotły i bojlery Plieger
- Kotły i bojlery Bulex
- Kotły i bojlery AWB
- Kotły i bojlery Quooker
- Kotły i bojlery OSO
- Kotły i bojlery La Nordica
- Kotły i bojlery Clage
- Kotły i bojlery Noveen
- Kotły i bojlery Joven
- Kotły i bojlery Daalderop
- Kotły i bojlery Fakir
- Kotły i bojlery Cointra
- Kotły i bojlery Eccotemp
- Kotły i bojlery Biasi
- Kotły i bojlery Thermor
- Kotły i bojlery Sentry
- Kotły i bojlery Burco
- Kotły i bojlery Khind
- Kotły i bojlery LEMET
- Kotły i bojlery Duwaco
- Kotły i bojlery IQE
- Kotły i bojlery Wahlbach
- Kotły i bojlery Ygnis
- Kotły i bojlery Dux
- Kotły i bojlery Intellihot
- Kotły i bojlery Airthereal
- Kotły i bojlery Thermoflow
- Kotły i bojlery IStore
- Kotły i bojlery Apricus
- Kotły i bojlery Aquamarin
- Kotły i bojlery Sime
- Kotły i bojlery Hydrotherm
- Kotły i bojlery Amtrol
- Kotły i bojlery Neopower
- Kotły i bojlery Gleamous
- Kotły i bojlery AquaMAX
- Kotły i bojlery My-PV
- Kotły i bojlery EvoHeat
- Kotły i bojlery Rheem
- Kotły i bojlery Solahart
- Kotły i bojlery ENEFT
- Kotły i bojlery Imarflex
- Kotły i bojlery MicroHeat
- Kotły i bojlery Noritz
Najnowsze instrukcje dla Kotły i bojlery
14 Października 2024
13 Października 2024
9 Października 2024
9 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024