Instrukcja obsługi EK Water Blocks EK-FC R9-290X

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla EK Water Blocks EK-FC R9-290X (2 stron) w kategorii Hardwarekoeling. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
All disclosures, noces and warranty condions are being wrien on the EKWB website. Please read terms of use. Released on 2 nd of April 2014. Revision 1.0
Installation and mounting manual for -FC R9-290X Lightning EK
water block
This product is intended for installation only by expert users. Please consult with a qualified technician for installation. Improper installation may result in damage to your equipment. EK Water Blocks assumes no liability
whatsoever, expressed or implied, for the use of these products, nor their installation. The following instructions are subject to change without notice. Please visit our web site at for updates. Before www.ekwb.com
installation of this product please read important notice, disclosure and warranty conditions printed on the back of the box.
Before you start using this product please follow these basic guidelines:
1. Please carefully read the manual before through before beginning with the installation process!
2. Please remove your motherboard from the computer to assure safest mounting process in order to prevent any possible damages to your CPU and/or motherboard’s circuit board (PCB).
3. The EK High Flow and EK-PSC type fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber O-ring gaskets.
4. The use of corrosion inhibiting coolants is always recommended for any liquid cooling system.
STEP 1: GENERAL INFORMATION. Sample picture of R9 Lightning graphics card MSI 290X
STEP 2: PREPARING YOUR GRAPHIC CARD.
1. REMOVING STOCK COOLER: Remove four (4) encircled screws on
the back of the PCB:
STEP 2 cont.: PREPARING YOUR GRAPHIC CARD
1 cont... REMOVING STOCK COOLER. Remove the stock GPU HSF assembly. Remove two (2)
encircled screws attaching the metal plate to the circuit board as well as two (2) screws attaching the I/O
bracket to the HSF. All heat sink assembly screws should be removed.
2. CLEANING THE PCB. Carefully detach the original stock cooler
after removing screws securing it to the board. Wipe off the all
remains (by using non abrasive cloth or
qtip
, as shown on sample
photo) of the original thermal compound until the components and
circuit board are completely clean. EKWB recommends the use of
denatured alcohol for removing TIM leftovers.
3. APPLYING THERMAL COMPOUND. Wipe off the remains
(by using non abrasive cloth or
q-tip
) of the original thermal
compound until the components and circuit board are
completely clean. Apply thermal compound: lightly coat
AMD
GPU chip with enclosed EK-TIM Ectotherm thermal grease.
EKWB recommends to apply thermal grease in cross form for
best performance (see sample picture).
4. CUTTING THERMAL PADS. Your block comes with thermal pads, some of which are already pre-cut. Others
have to be cut to smaller chunks in order to cover all the VRM components such as MOSFETs and drivers.
PLEASE REMOVE THE PROTECTIVE FOIL FROM
BOTH SIDES OF THE THERMAL PADS PRIOR TO
INSTALLATION.
Replacement thermal pads:
Thermal Pad D 0.5mm (RAM 16x),
Thermal Pad 1.0 mm (100x16 ) A mm
STEP 3: INSTALLING THE WATER BLOCK
PLACING THERMAL PADS ON PCB. Place thermal pads on chips so that numbers on chips match size of thermal pads. EKWB made sure users have more than enough
pads to cover all surfaces that need to be covered to make block fully functional). EKWB recommends using small drops of electrically non-conductive (for example: EK-
TIM Ectotherm, Arctic Cooling MX- - -2 ™, MX 4 or GELID GC Extreme™) thermal grease on each phase regulator (that is being covered with thermal pad) in order to
even further improve the thermal performance of the EK-FC -290X Lightning block. R9
1
1
1
1
1
1
1
1
1
1
2
1
1
1: Thermal pad D 0.5mm
(for memory IC):
2: Thermal pad A 1.0mm
(for VDD VRM):
1
1
1
1
1
1
1
1
2
2
2
All disclosures, noces and warranty condions are being wrien on the EKWB website. Please read terms of use. Released on 2 nd of April 2014. Revision 1.0
2. PLACING THE BLOCK ON TO THE GRAPHICS CARD. Carefully position the water
block with preinstalled standoffs on to the graphics card. During this process please
make sure you align mounting holes on the PCB with holes on the water block (same
applies for other tops). Also pay attention not to use too much force by pressing the
block down to the PCB. Chip dies are prone to cracking.
3. ATTACHING THE BLOCK TO THE GRAPHIC CARD. Use Philips screwdriver a
screw with the enclosed M3x4 DIN 7985 screws. EKWB recommends users to start
tightening the screws around the GPU core and continue outwards. Always use a
washer under each and every screw. The original backplate cannot be re-used
without modification when using EK-FC R9-290X Lightning water block.
STEP 4: CHECKING FOR CONTACTS
If necessary temporarily r
emove the water block to check for uniform surface contact between the block and the components, pay special attention to the VRM section of the
graphics card. Check whether the water block makes contact with the intended integrated circuit. Then repeat sub-steps in previous section to re-attach the block. In case you
fail to obtain good contact, please check again that your thermal pad thickness or contact our support service at http://www.ekwb.com/support.
STEP 5: INSTALLATION OF FITTINGS AND TUBING
Screw in the two G1/4 threaded male fittings. Attach the liquid cooling tubes and connect the water-block(s) into the cooling circuit. EKWB recommends using EK-CSQ
fittings with the EK-FC - Lightning series water blocksR9 290X . To ensure that the tubes are securely attached to the barb/fittings, please use hose clamps or an
appropriate substitute.
You can use any opening as an inlet/outlet port.
CAUTION: In case of using connectors other than EK-CSQ or EK-PSC series compression ttings, fi take special attention to the length of the fittings’ male G1/4” thread. In case
the thread is longer than 5 mm please use the enclosed 1.8 mm nickel plated spacer!
5mm is the maximum allowed G1/4” thread length!
STEP 6: INSERTING THE CARD IN YOUR PC CASE
Carefully lift your graphics card with installed block and insert it in your PC’s motherboard PCI-express expansion slot. Please bear in mind that your graphics card is probably
heavier than when it was equipped with original heat sink fan assembly. One needs to be very careful when handling the graphics card. Avoid all un-needed manipulation of the
VGA/water block assembly that might damage your card or water block during final installation.
REQUIRED TOOLS:
scissors Philips head screwdriver
EK-CSQ Fing
Tubing
EK-Plug G1/4
Acetal Terminal
M3x4 DIN7985 screw
PVC washer
If no washer is present on PCB
please use the ones enclosed
with the water block!

Specyfikacje produktu

Marka: EK Water Blocks
Kategoria: Hardwarekoeling
Model: EK-FC R9-290X

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z EK Water Blocks EK-FC R9-290X, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Hardwarekoeling EK Water Blocks

Instrukcje Hardwarekoeling

Najnowsze instrukcje dla Hardwarekoeling

Noctua

Noctua NH-D9 DX-3647 4U Instrukcja

3 Października 2024
Noctua

Noctua NF-A12x15 Instrukcja

3 Października 2024
Noctua

Noctua NF-A4x20 Instrukcja

3 Października 2024
Noctua

Noctua NF-A12X25R PWM Instrukcja

3 Października 2024
Noctua

Noctua NF-A4x10 Instrukcja

3 Października 2024
Cougar

Cougar Poseidon GT 360 Instrukcja

3 Października 2024
In Win

In Win Jupiter AJ120 Instrukcja

3 Października 2024
DeepCool

DeepCool AS500 Plus Instrukcja

3 Października 2024
DeepCool

DeepCool AK500S Digital Instrukcja

3 Października 2024