Instrukcja obsługi Eastron SDM72D-M
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Eastron SDM72D-M (12 stron) w kategorii miary. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/12

Eastron SDM72D-M User Manual V1.5
Zhejiang Eastron Electronic Co.,Ltd. Tel: 0086-573-83698881 83698882 Fax: 0086-573-83698883
Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. Web: www.eastron.com.cn Email: sales@eastrongroup.com
- 1 -
Measures active kWh & W.
Resettable partial energy
Bi-directional measurement IMP & EXP
Pulse Output
RS485 Modbus
Din rail mounting 35mm
Direct connection, up to 100A
Better than Class 1/ B accuracy
SDM72D-M
Three Phase Four Wire Energy Meter
User Manual V1.3
2017

Eastron SDM72D-M User Manual V1.5
Zhejiang Eastron Electronic Co.,Ltd. Tel: 0086-573-83698881 83698882 Fax: 0086-573-83698883
Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. Web: www.eastron.com.cn Email: sales@eastrongroup.com
- 2 -
Introduction
The SDM72D-M is digital three phase 4 wire energy meter with a white back-lighted LCD screen for perfect
reading. The unit measures and displays active energy (kWh) and power ( W), imported and exported. A resettable
partial energy is provided, so the user can easily check the energy imported and energy exported during a certain
period. SDM72D-M supports max.100A direct connection, saves the cost and avoid the trouble to connect
external CTs, giving the unit a cost-effective and east operation. Built-in interfaces provides pulse and RS485
Modbus RTU outputs. Configuration is password protected.
PART 1 Specification
General Specifications
Voltage AC (Un) 3x230(400)V
Voltage Range 80~120% Un
Base Current (Ib) 10A AC
Max. Current (Imax) 100A AC
Mini Current (Imin) 5% of Ib AC
Starting current 0.4% of Ib
Power consumption <2W/10VA
Frequency 50/60Hz
AC voltage withstand 4KV for 1 minute
Impulse voltage withstand 6KV-1.2uS wavform
Overcurrent withstand 30max 0I for 0.01s
Pulse output rate 1000imp/kWh (Pulse 2)
Display LCD with backlit
Max. Reading 999999.9kWh
Active energy Class 1 IEC62053-21
Class B EN50470-3
Unit Characteristics
The Unit can measure and display:
Power
Active energy imported and exported
Pulse output indicates real-time energy measurement. An RS485 output allows remote monitoring from another
display or a computer.
RS485 Serial Modbus RTU
–
–
–
––
This unit uses an RS485 serial port with Modbus RTU protocol to provide a means of remotely monitoring and
controlling the Unit
Set-up screens are provided for setting up the RS485 port.

Eastron SDM72D-M User Manual V1.5
Zhejiang Eastron Electronic Co.,Ltd. Tel: 0086-573-83698881 83698882 Fax: 0086-573-83698883
Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. Web: www.eastron.com.cn Email: sales@eastrongroup.com
- 3 -
Pulse output
The unit provides pulse output for active kWh. The Pulse output is passive type.
The pulse out is fixed up with total kWh. The constant is 1000imp/kWh.
RS485 Output for Modbus RTU
For Modbus RTU, the following RS485 communication parameters can be configured from the Set-up menu:
Baud rate 1200,2400, 4800, 9600
Parity none (default)/odd/even
Stop bits 1 or 2
RS485 network address nnn – 3-digit number, 001 to 247
Modbus™ Word order Hi/Lo byte order is set automatically to normal or reverse. It cannot be configured
from the set-up menu.
Environment
Operating temperature -25 to +55℃ ℃
Storage and transportation temperature -40 to +70℃ ℃
Reference temperature 23 2℃± ℃
Relative humidity 0 to 95%, non-condensing
Altitude up to 3000m
Warm up time 10s
Installation category CAT III
Mechanical Environment M1
Electromagnetic environment E2
Degree of pollution 2
Mechanics
Din rail dimensions 72x100x66 (WxHxD) DIN 43880
Mounting DIN rail 35mm
Sealing IP51 (indoor)
Material self-extinguishing UL94V-0
PART 2 Operation
Initialization Display
When it is powered on, the meter will initialize and do self-checking.
Specyfikacje produktu
Marka: | Eastron |
Kategoria: | miary |
Model: | SDM72D-M |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Eastron SDM72D-M, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje miary Eastron

5 Maja 2024
Instrukcje miary
- miary PeakTech
- miary Joy-It
- miary SHX
- miary Voltcraft
- miary Bosch
- miary GW Instek
- miary Panasonic
- miary Be Cool
- miary Rossmax
- miary Hazet
- miary Garmin
- miary Testo
- miary ORNO
- miary Chauvin Arnoux
- miary Uni-T
- miary Owon
- miary Hilti
- miary Schneider
- miary Sonel
- miary Perel
- miary Janitza
- miary Trotec
- miary Velleman
- miary Intellinet
- miary Gossen Metrawatt
- miary Fluke
- miary Megger
- miary Greisinger
- miary Mitsubishi
- miary Weidmüller
- miary Camille Bauer
- miary Metrix
- miary Rigol
- miary TDE Instruments
- miary Hama
- miary Eltako
- miary Hager
- miary Extech
- miary Testboy
- miary Stabila
- miary Kyoritsu
- miary Klein Tools
- miary ENTES
- miary Burg Wächter
- miary Lund
- miary Wiha
- miary Pico
- miary Stahlwille
- miary AkYtec
- miary Wachendorff
- miary Kern
- miary Adwa
- miary Müller
- miary Beha-Amprobe
- miary Ermenrich
- miary Laserliner
- miary Cocraft
- miary Kopp
- miary Hikmicro
- miary Siglent
- miary Murideo
- miary Ideal
- miary ABB
- miary Flir
- miary Cablexpert
- miary Tektronix
Najnowsze instrukcje dla miary

28 Września 2024

26 Września 2024

24 Września 2024

24 Września 2024

24 Września 2024

24 Września 2024

24 Września 2024

16 Września 2024

14 Września 2024

14 Września 2024