Instrukcja obsługi Drawmer 1977


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Drawmer 1977 (12 stron) w kategorii nieskategoryzowany. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/12
OPERATOR’S MANUAL
CONTENTS
Warranty
Safety Consideration
Chapter 1 - Introduction
Introduction
Installation
Power Connection
Audio Connections
Chapter 2 - Control Description
Control Description
Chapter 3 - General Information
If a fault develops
Contacting Drawmer
Specication Data
Block Diagram
Recall Sheet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2 1977 OPERATOR’S ANUALM
Drawmer Electronics Ltd., warrants the Drawmer 1977
Channel Strip to conform substantially to the specications
of this manual for a period of one year from the original
date of purchase when used in accordance with the
specications detailed in this manual. In the case of a
valid warranty claim, your sole and exclusive remedy
and Drawmer’s entire liability under any theory of liability
will be to, at Drawmers discretion, repair or replace the
product without charge, or, if not possible, to refund the
purchase price to you. This warranty is not transferable.
It applies only to the original purchaser of the product.
For warranty service please call your local Drawmer
dealer. Alternatively call Drawmer Electronics Ltd. at
+44 (0)1709 527574. Then ship the defective product,
with transportation and insurance charges prepaid, to
Drawmer Electronics Ltd., Coleman Street, Parkgate,
Rotherham, S62 6EL UK. Write the RA number in large
letters in a prominent position on the shipping box.
Enclose your name, address, telephone number, copy
of the original sales invoice and a detailed description of
the problem. Drawmer will not accept responsibility for
loss or damage during transit.
This warranty is void if the product has been damaged by
misuse, modication or unauthorised repair.
THIS WARRANTY IS IN LIEU OF ALL WARRANTIES,
WHETHER ORAL OR WRITTEN, EXPRESSED,
IMPLIED OR STATUTORY. DRAWMER MAKES NO
OTHER WARRANTY EITHER EXPRESS OR IMPLIED,
INCLUDING, WITHOUT LIMITATION, ANY IMPLIED
WARRANTIES OF MERCHANTABILITY, FITNESS FOR
A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.
PURCHASER’S SOLE AND EXCLUSIVE REMEDY
UNDER THIS WARRANTY SHALL BE REPAIR OR
REPLACEMENT AS SPECIFIED HEREIN.
IN NO EVENT WILL DRAWMER ELECTRONICS LTD.
BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING FROM ANY DEFECT IN THE PRODUCT,
INCLUDING LOST PROFITS, DAMAGE TO PROPERTY,
AND, TO THE EXTENT PERMITTED BY LAW, DAMAGE
FOR PERSONAL INJURY, EVEN IF DRAWMER HAS
BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES.
Some states and specic countries do not allow the
exclusion of implied warranties or limitations on how long
an implied warranty may last, so the above limitations may
not apply to you. This warranty gives you specic legal
rights. You may have additional rights that vary from state
to state, and country to country.
In the interests of product development, Drawmer reserve the right to modify or im-
prove specications of this product at any time, without prior notice.
ONE YEAR LIMITED WARRANTY
COPYRIGHT
This manual is copyrighted © 2023 by Drawmer Electronics Ltd. With all rights reserved. Under copyright
laws, no part of this publication may be reproduced, transmitted, stored in a retrieval system or translated
into any language in any form by any means, mechanical, optical, electronic, recording, or otherwise, without
the written permission of Drawmer Electronics Ltd.
1977
Channel Strip
SAFETY CONSIDERATIONS
CAUTION - MAINS FUSE
TO REDUCE THE RISK OF FIRE
REPLACE THE MAINS FUSE ONLY WITH
A FUSE THAT CONFORMS TO IEC127-2.
250 VOLT WORKING, TIME DELAY TYPE
AND BODY SIZE OF 20mm x 5mm.
THE MAINS INPUT FUSE MUST BE
RATED AT 230V=T250mA and 115V=T500mA.
CAUTION - MAINS CABLE
DO NOT ATTEMPT TO CHANGE
OR TAMPER WITH THE
SUPPLIED MAINS CABLE.
CAUTION - SERVICING
DO NOT PERFORM ANY SERVICING.
REFER ALL SERVICING TO QUALIFIED
SERVICE PERSONNEL.
WARNING
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT EXPOSE
THIS EQUIPMENT TO RAIN OR MOISTURE.
3
1977 OPERATOR’S ANUALM
CHANNEL STRIP
CHAPTER 1
INTRODUCTION
If youre looking to add vintage characteristics and
analogue musicality to your recordings then look no further
than the 1977, Drawmer’s most comprehensive channel
strip to date.
The 1977 gives you the clarity of an ultra clean preamplier,
the precision of the three band parametric equaliser, the
silkiness of the soft knee compressor and added to this
the ability to dial in as much warmth as you desire via the
3 types of variable harmonic saturation.
The pristine preamplier not only incorporates mic, line and
instrument D.I. with 66dB of stepped gain, allowing you
to make ultra clean, transparent and precise recordings,
sweeten up dull audio or perfect your guitar sound, but
also mic matching via switched impedance that brings out
the best of every mic in your studio. Whether high-end,
ribbon or even your dullest mic you will be able to nd it’s
sweet spot.
The 1977 incorporates a true ‘parametric’ equaliser, with
three bands of fully variable frequency control and cut
and boost of +/-12dB’s and, in addition, a fully variable
bandwidth control of the mid band, making it incredibly
versatile and capable of modifying everything from subtle
ne tuning to tone sculpting problematic recordings, and,
of course, anything in between.
A full featured compressor allows you to control the
dynamics of your recordings and our trademark Big’
and ‘Air modes help to preserve the very deep lows and
enhance the sparkling highs that lesser compressors
remove. The compressor section also incorporates variable
harmonic Saturation with a choice of 3 styles, that will allow
you to warm up your recordings with complete precision.
The output section includes wet/dry mix for parallel a
processing that allows you to easily dial in how much EQ
and compression is used via a single knob, plus an output
fade control to either add fade outs or to boost the level to
match high end audio interface audio input levels, along
with a large backlit VU meter for accurate monitoring.
And nally, a Preamp Direct switch that bypasses the EQ,
compressor and Saturation completely to provide an ultra
clean microphone output.
The result of all these features is a modern take on vintage
gear that gives you an incredible degree of control over
the clarity, tone and warmth of your recordings, helping
you to capture perfect audio every time.
Features:
A THAT Corporation ultra clean mic preamplier with
66dB of gain with phantom power and switchable mic
impedance for accurate mic matching
Separate Line & Mic input XLRs and pro quality
instrument DI input with through output. Plus an XLR
for the dedicated ultra clean direct pre-amp output and
also for the overall output.
FETs can be bypassed altogether to provide ultra clean
outputs.
A variable high pass lter control removes any rumble
and allows you to tighten up the bottom end
Phase reverse.
Vintage-style three band full parametric EQ which takes
its inspiration from 1970’s-era analogue gear, with
variable frequency, +/-12dB cut and boost and variable
bandwidth. Switch able slopes plus low peak settings
allows you to adjust the focus and also magnify the
bottom and top ends.
Compressor includes standard controls and also ‘Big’
and ‘Air Modes Help to preserve the very deep lows
and enhance the sparkling highs.
Rear panel Side-chain insert point provides even further
control.
3 types of variable Saturation adds vintage warmth.
The order of the EQ and Compressor can be swapped
and also each can bypassed to allow for comparisons.
Variable Wet/Dry Mix plus Output Gain knobs give a
‘Parallel E.Q. and Compression’ function without the
need for external mixing devices, providing complete
and e󰀨ortless control over the amount of equalisation
and compression used and output levels.
A backlit Analogue V.U. Meter with Switch able +10dB
Re-scale Mode.
Time delay relays on the output for clean power up/down.
Internal Low Hum Toroidal Linear Power Supply with
Voltage Selector Switch.
Classic Drawmer build quality with rugged steel chassis
and aluminium front panel.
Designed and Handmade by Drawmer in the UK.


Specyfikacje produktu

Marka: Drawmer
Kategoria: nieskategoryzowany
Model: 1977

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Drawmer 1977, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Drawmer

Drawmer

Drawmer 1960 Instrukcja

24 Września 2024
Drawmer

Drawmer 1977 Instrukcja

24 Września 2024
Drawmer

Drawmer 4X4R Instrukcja

24 Września 2024
Drawmer

Drawmer DMS-2 Instrukcja

24 Września 2024
Drawmer

Drawmer DL441 Instrukcja

24 Września 2024
Drawmer

Drawmer DS404 Instrukcja

24 Września 2024
Drawmer

Drawmer DS201 Instrukcja

24 Września 2024

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024