Instrukcja obsługi Doepfer A-196


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Doepfer A-196 (8 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/8
doepfer System A - 100 PLL A-196
1
1. Introduction
Module A-196 contains a so-called Phase Locked
Loop circuit (PLL). A PLL consists of three parts:
VCO (linear voltage-controlled oscillator with rectangle
output), phase comparator (PC), and low-pass filter
(LPF). The three parts are connected in the A-196 with
normalled sockets to form the standard closed-loop
PLL frequency-feedback system. The normalled soc-
kets allow individual access to each part of the PLL
and enable other patches than the standard PLL (e.g.
insertion of external modules).
The andVCO is equipped with the controls Range
Offset. The range switch is used to select one of three
frequency ranges. The Offset control defines the maxi-
mum frequency of the VCO.
The module contains three different types of phase
comparators that are selected with a 3-position
switch.
The LED indicates if the PLL is locked for PC2 , i.e. if
the frequency of the internal VCO is the same as the
frequency of the external input signal.
The frequency of the built-in low pass filter is manu-
ally adjusted with the frequency control.
CV In
locked (2)
Offset
A-196
PLL
Out
In 1
Range
Out
VCO
Type
In 2
(Signal)
Out
PC
LPF
Frequ.
A-196 PLL System A - 100 doepfer
2
2. Basic principles
The three units VCO, phase comparator (PC) and low
pass filter (LP) form a standard closed-loop frequency-
feedback system: The VCO output (linear response,
rectangle output) is compared with an external signal
(e.g. A-110 VCO) in the PC. The PC output is a digital
high/low signal that indicates if the frequency resp.
phase difference of the two input signals is negative,
zero or positive. This signal is processed by the LP to
generate a smooth control voltage that controls the
frequency of the VCO. The units VCO, PC and LPF
form a frequency feedback loop that works like this:
The CV (LP output) increases (decreases) as long as
the external frequency is higher (lower) than the fre-
quency of the internal VCO and stops increasing as
soon as both frequencies become identical.
But there are some stumbling blocks: Different types
of phase comparators with advantages and disad-
vantages can be made. Some phase comparators e.g.
even lock at harmonics, i.e. if the two frequencies to be
compared are integer multiples. For some applications
this "fault" may be used to create interesting effects.
The A-196 contains 3 different types of phase compa-
rators: PC1 is a simple exclusive OR, that even locks
at harmonics. PC2 is a so-called RS flipflop and PC3 a
more complex digital memory network. The user can
select one of the three phase comparators with a
3-position switch. When PC2 is used a LED displays
the "locked" state, i.e. when the frequency of the
internal VCO is identical to the external frequency.
Special attention has also to be directed to the fre-
quency of the LP. To obtain a smooth control voltage
for the VCO the frequency of the LP has to be much
smaller than the lowest frequency of the internal or
external audio signal. Otherwise the frequency of the
internal VCO will jitter or wobble around the correct
frequency. But for special effects this frequency jitter
can be used intentionally.
Example: frequencies in the range 50Hz...1kHz have
to be processed with the PLL. Therefore the frequency
of the LP has to be about 10Hz or even less. Such a
low frequency of the LPF causes a noticeable slew of
the internal VCO. When the frequency of the external
signal jumps e.g. between 50Hz and 1kHz it takes
about 0.1 second until the internal VCO reaches the
new frequency (like portamento). Consequently one
has to find a compromise between the frequency jitter
and portamento. But these remarks are valid only for
the "ideal" working PLL. As the A-196 is used in a
musical enviroment these "problems" and "dis-
advantages" with jitter and slew time lead to additional
musical applications like portamento effects, wobbling
frequencies or harmonic locking according to the type
of frequency comparator and time constant of the PLL
low pass filter.
doepfer System A - 100 PLL A-196
3
Fig. 1: Internal construction of the A-196


Specyfikacje produktu

Marka: Doepfer
Kategoria: Niesklasyfikowane
Model: A-196

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Doepfer A-196, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Doepfer

Doepfer

Doepfer A-100 Instrukcja

4 Października 2024
Doepfer

Doepfer Dark Link Instrukcja

22 Września 2024
Doepfer

Doepfer A-196 Instrukcja

22 Września 2024
Doepfer

Doepfer A-134 Instrukcja

21 Września 2024
Doepfer

Doepfer A-135-2v Instrukcja

21 Września 2024
Doepfer

Doepfer A-145 Instrukcja

21 Września 2024
Doepfer

Doepfer A-101-2 Instrukcja

21 Września 2024
Doepfer

Doepfer A-99 Instrukcja

20 Września 2024
Doepfer

Doepfer A-103 Instrukcja

20 Września 2024
Doepfer

Doepfer A-165 Instrukcja

20 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024