Instrukcja obsługi Dimplex PX01001


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Dimplex PX01001 (3 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 8 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/3
Contact Details
Pleasenotethat some contact ofthe details on 
thisPDFdocumentmaynotbe current.
Pleaseuse  the following detailsifyouneedto
contactus:
Telephone:0844 879 3588
Email:customer.services@gdcgroup.co.uk
The widecustomer alsosupportsection websiteofour  features a
rangeof ofinformationwhichmaybe use availabletoyouandis 
24 ahours day.Itincludes:
Operating  and installation instructions
Easy   ‘How to use’ guides for storage heaters
Service  and repairs
Wheretobuyourproducts
Literature downloads
Heating  requirement calculator
 ‐Visit www.dimplex.co.uk/support
A division of GDC Group Ltd
Millbrook House Grange Drive Hedge End Southampton SO30 2DF
www.dimplex.co.uk
Re
g
istered No: 1313016 En
g
land
VAT GB 287 1315 50004
EEE Producer Registration Number
WEE/GE0057TS
Paper from sustainable sources
2. The location of the control is important, it will not function
correctly if above or within 500mm of a heat source or
draught. Care must also be taken not to obscure the slots at
the top or bottom of the control and that it is not exposed to
direct bright sunlight or close to a lamp fitting. Best
temperature accuracy will be achieved by mounting on an
internal wall or partition.
3. The pattress boxes (not provided) should have a depth of at
least 25mm. Plastic pattress boxes with vertical pillars are not
suitable.
Vertical tabs in metal pattress boxes should be removed.
Ensure all entries into the pattress boxes are sealed to
prevent draughts.
4. Before fitting to the mounting box setback temperature,
comfort temperature and comfort period must be selected. To
do this, adjust the appropriate dial on the reverse of the PCB.
5. The supply cable is not provided and should therefore be
selected to suit the appliance.
Warning: Although the control does not need an earth, the
appliance probably does. Ensure that the mounting box is
fitted with an earth terminal for earth continuity to the
appliance.
6. To connect the control in circuit wire in to the clearly marked
terminal block on the rear of the controller. The control must
only be connected via fixed wiring.
7. Secure the control to the pattress box such that there are no
gaps between the controller and wall or pattress box.
Note: If tamperproof screws are required they should be M3 x 40mm
long, counter sunk with a head diameter of no more than 6.5mm.
Installation and
Operating Instructions
Press Button Delay Timer -
Model No. PX01001
Safety Warnings
1. WARNING: DO NOT USE THIS APPLIANCE IN THE
IMMEDIATE SURROUNDINGS OF A BATH, A SHOWER
OR SWIMMING POOL
2. WARNING: DO NOT USE WHERE EXCESSIVE DUST OR
MOISTURE IS PRESENT
3. WARNING: FOR USE IN NORMAL POLLUTION
SITUATIONS ONLY
General Description
The PX01001 timer/thermostat can be used in conjunction with
heating appliances. They may be flush or surface mounted using a
standard 25mm box. The control is rated at 16A (250VAC) and can
be used in conjunction with heating appliances with a maximum total
input of 13 A resistive L.C. 230V - 50Hz. The controller cannot be
used with a Quartz heater without a suitable in-line contactor.
Control action: Type 1B
Operating Instructions
The PX01001 controls the room temperature by interrupting the
power supply to the appliance, therefore the appliance should
always be switched on and its thermostat set to maximum
temperature. Note this will not be reached if the pre-determined
maximum level is below that of the appliance thermostat setting.
When the comfort mode is activated by pressing the
centre of the control face, the green light illuminates.
The comfort mode allows the room to be heated to a pre-
determined temperature for a pre-determined time
period.
The red light indicates that the heater is operating.
Note that the heater will remain on for a minimum of 1
minute.
The red light may also be illuminated in the set back
mode when the PX01001 switches the heater on to
maintain the predetermined background temperature.
Installation
Before undertaking installation work, ensure the electricity supply is
disconnected from any relevant fixed wiring.
1. The control and heater should be installed in compliance with
the IEE Wiring Regulations
co mfort
control
Dimplex
TOUCH
85mm
85mm
25mm
boost
Main Dimensions
boost
Ensure 500mm clearance from any heat source or draught.
T0105/004/A
General Cleaning
WARNING
BEFORE UNDERTAKING CLEANING WORK ON THE
CONTROLLER OR APPLIANCE IMMEDIATELY DISCONNECT
THE ELECTRICITY SUPPLY BY SWITCHING OFF AT THE
ADJACENT DOUBLE POLE SWITCH.
The outside of the appliance should be wiped over with a soft damp
cloth and then dried. Do not use detergents or abrasives.
After Sales Service
Your Dimplex Comfort Control is guaranteed for one year from date
of purchase. We undertake to exchange or repair free of charge
within this period, any part found to be defective.
Should you require after sales service, please get in touch with the
supplier through whom you purchased the appliance, or your
nearest Service Agent.
Please do not initially return a faulty appliance or part of an appliance
to us as this may result in transit damage and/or delay in providing
service. Let us know your difficulty quoting the model number and
series of the appliance. We will then take the appropriate action.
L
Live
Output
Live
Neu- N
Setback
temp.
Comfort
temp.
Timing
16ºC 25ºC 19ºC C
Comfort Temperature Setback Temperature
Glen Dimplex UK Ltd
Millbrook House
Grange Drive
Hedge End
Southampton
Hampshire SO30 2DF
Customer Services: Tel. 0870 7270101
Fax. 0870 7270102
email customer.services@glendimplex
Republic of Ireland Tel. 01 8424833
HEATER
OUT
IN
IN
OUT
L
N
Control SWITCHED
FUSED
SPUR
Minimum 500mm
230VAC MAINS
FROM FUSED or
BREAKERED
SOURCE
Ensure the heater is properly
earthed with the Fused Spur
Wi i ir ng D a agr m
HEATER
OUT
IN
IN
OUT
L
N
Control SWITCHED
FUSED
SPUR
Minimum 500mm
230VAC MAINS
FROM FUSED or
BREAKERED
SOURCE
Ensure the heater is properly
earthed with the Fused Spur
Al it te arn ve
0 240
Timing (Mins)
Installation contd..


Specyfikacje produktu

Marka: Dimplex
Kategoria: Niesklasyfikowane
Model: PX01001

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Dimplex PX01001, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Dimplex

Dimplex

Dimplex GDDEU30 Instrukcja

2 Października 2024
Dimplex

Dimplex OCR20Tie Instrukcja

2 Października 2024
Dimplex

Dimplex OPH13 Instrukcja

30 Września 2024
Dimplex

Dimplex ALM20E Instrukcja

28 Września 2024
Dimplex

Dimplex TDTR175C Instrukcja

27 Września 2024
Dimplex

Dimplex BYP20 Instrukcja

22 Września 2024
Dimplex

Dimplex MZT20E Instrukcja

20 Września 2024
Dimplex

Dimplex MZT20BL-E Instrukcja

20 Września 2024
Dimplex

Dimplex GLN20BR Instrukcja

19 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024