WARNING - A REGULATED UL / CSA APPROVED 12V DC / 24V AC
power supply is REQUIRED for use with this camera. Use of a non-
regulated, non-conforming power supply can damage this product and
voids the warranty.
Product Information
User Manuals Quick Start Guides
Specification Sheets
Video Tutorials & DemosLatest News
Contents
700+ TVL
VARIFOCAL IR BULLET CAMERA
MODEL: DCB54DL
QUICK START GUIDE
English Version 1.0
www.digimerge.com
IT’S ALL ON THE WEB!
www.digimerge.com
VISIT
Digimerge Technologies Inc.
Copyright © 2012
As our products are subject to continuous improvement, Digimerge
reserves the right to modify product design, specifications and prices,
without notice and without incurring any obligation. E&OE
1 x Weatherproof IR Bullet
Camera with Varifocal Lens
4 x Mounting Screws
1 x Large Allen Key
1 x Small Allen Key
1 x Mounting Template
Features
Safety Precautions
• Use an appropriate low voltage power cable to prevent fire or electrical shock.
• Make sure to install the camera in an area that can support the camera weight.
• There are no user serviceable parts inside the camera. Please do not
disassemble the camera.
• Do not clean the lens cover with an abrasive cleaning material. Please use a
soft cloth to clean the lens cover.
• 1/3” Sony EX-View™ II 960H with Effio DSP / 700+TVL
• Superior low light sensitivity and vibrant color
reproduction
• 110ft (34m) IR Night Vision Range*
• 2.8–12mm Varifocal Lens
• External Zoom / Focus Adjustment
• IP66 Weatherproof Rating**
• Cable Through Bracket Design
• 12V DC / 24V AC Operation
* IR Illumination range under ideal conditions. Objects at or beyond
this range may be partially or completely obscured, depending on the
camera application
** Not recommended for submersion in water
Ultra Resolution,
Outstanding Value Cameras
Ultra Resolution Cameras
with Advanced Features
Fully Connected DVRs
Camera base
Fastening screw
Adjustment ring
Camera Stand Screws
FOCUS ZOOM
Screw
Installing the Camera
ATTENTION - Test the camera prior to selecting a permanent
mounting location by temporarily connecting the camera(s) and
cables to the DVR or Observation System.
Image Sensor 1/3” Sony EX-View™ II 960H
Video Format NTSC
Effective Pixels H: 976 V: 494
Horizontal Resolution 700+ TVL
Scan System 2:1 Interlace
Sync System Internal
S / N Ratio >50dB (AGC Off)
Iris AES
AES Shutter Speed 1/60 ~ 1/100,000 sec.
Min. Illumination 0.15 LUX @ F2.0 (IR Off)
0 LUX (IR LEDs ON)
Video Output Composite 1.0Vpp @ 75ohm
Lens Focal Length / Type 2.8–12mm F1.4 / Varifocal
FOV (Diagonal) 28–93°
Termination Video: BNC Female
IR Range / Qty. 110ft / 34m; 30 LED’s
Power Requirement 12V DC ± 10% / 24V AC ± 10%
Power Consumption 12V: 600mA max / 24V: 400 mA max
Operating Temp. Range –4° ~ 122°F
Environmental Rating IP66
Dimensions (LxWxH) 10.1” x 5.4” x 3.4”
255mm x 137mm x 85mm
Weight (including stand) 1.9lbs / 0.9kg
Dimensions
Camera SpecificationsSetting up the Camera
1. Connect the BNC connector of the camera to
the video cable.
2. DC Power— : Connect a Power Adapter
12V DC Power Adapter (not included) to the
camera. Plug the Power Adapter into a local
power outlet.
•DC Power— (not included): Power Pigtail
Connect a Power Pigtail to the camera.
Connect the terminating wires of the cable
directly to the DC power source.
NOTE: The Power Pigtail is a non-polarity input. You
can connect the wires to either the positive or negative
ports of the DC power source.
•AC Power—Connect a Power Pigtail
(not included) to the camera. Connect the
terminating wires of the cable directly to the
24V AC power source.
3. Adjust the ZOOM and FOCUS knobs as
required.
1. Use the included mounting template to
mark mounting points.
2. Loosen the fastening screw at camera base
using the small allen key.
255mm / 10.1” 137mm / 5.4”
85mm
3.4”
3. Rotate the camera base counter clockwise
to separate it from the camera stand.
4. Mount the camera base to the wall using
the included screws.
NOTE: This camera is not intended for ceiling
mounting. If you mount the camera to a ceiling, the
camera will have to point downwards for adequate
clearance.
5. Loosen the camera
stand screws using
the large allen key.
6. Feed the BNC /
power termination
cable through the
camera base. Connect video and power
cable as described in next section ‘Setting
up the Camera’.
7. Screw the camera clockwise onto the
camera base. Do not tighten all the way.
8. Move the camera to the desired position,
and while holding it firmly in place, turn
the adjustment ring on the camera stand
clockwise to tighten. Next, tighten the two
screws on the camera stand.
NOTE: If the ZOOM and FOCUS knobs are too tight for
adjustment, use a philips screw driver to slightly loosen
the screws on the knobs.


Specyfikacje produktu

Marka: Digimerge
Kategoria: Kamera monitorująca
Model: Echelon DCB54DL

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Digimerge Echelon DCB54DL, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Kamera monitorująca Digimerge

Instrukcje Kamera monitorująca

Najnowsze instrukcje dla Kamera monitorująca