AC/DC Enclosed Switching Power Supply
LMF150-23Bxx, LMF150-23Bxx-C, LMF150-23Bxx-Q Series
2020.11.30-A/1 Page 1of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Selection Guide
Certification
Part No.*
Output
Power(W)
Nominal Output
Voltage and Current
(Vo/Io)
Output Voltage
Adjustable Range(V)
Max. Capacitive Load
(µF)
UL/CE/CB/
CCC
LMF150-23B12
150
12V/12.5A
10.2-13.8
5000
LMF150-23B15
150
15V/10A
13.5-18
5000
LMF150-23B24
151.2
24V/6.3A
21.6-28.8
5000
LMF150-23B48
153.6
48V/3.2A
45.6-55.2
3000
Note*Use suffix ”C” for terminal with protective cover and suffix ”Q” for conformal coating.
Input Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Input Voltage Range
AC input
85
--
305
VAC
DC input
120
--
430
VDC
Input Voltage Frequency
47
--
63
Hz
Input Current
85VAC
--
--
2.5
A
115VAC
--
--
2.0
230VAC
--
--
1.0
Inrush Current
115VAC
Cold Start
--
--
30
230VAC
--
--
45
Power Factor
115VAC
At full Load
0.97
0.99
--
--
230VAC
0.91
0.98
--
Leakage Current
277VAC
2mA
Hot Plug
Unavailable
CB RoHS
FEATURES
Universal 85 - 305V AC or 120 - 430VDC Input voltage
Accepts AC or DC input (dual-use of same terminal)
Operating temperature range: -30 to +70℃ ℃
Built-in active PFC function
High I/O isolation test voltage up to 4000VAC
Output short circuit, over-current (Built-in constant
current limiting circuit), over-voltage,
over-temperature protection
Remote ON-OFF control
Safety according to UL/EN/IEC62368, EN60335,
GB4943
Over-voltage class (designed to meet EN61558)
Operating altitude up to 5000m
LMF150-23Bxx series is one of Mornsun’s enclosed AC-DC switching power supply. It features universal AC input and at the same time
accepts DC input voltage, cost-effective, built-in active PFC function, high efficiency and high reliability. These converters offer excellent
EMC performance and meet IEC/EN61000-4, CISPR32/EN55032, UL/EN/IEC62368, EN60335, GB4943 standards and they are widely used in
areas of industrial, LED, street light control, electricity, security, telecommunications, smart home etc.
AC/DC Enclosed Switching Power Supply
LMF150-23Bxx, LMF150-23Bxx-C, LMF150-23Bxx-Q Series
2020.11.30-A/1 Page 2of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Output Voltage Accuracy
Full Load Range
12V/15V
--
±2
--
%
24V/48V
--
±1
--
Line Regulation
Rated Load
--
±0.5
--
Load Regulation
0% - 100% load
--
±0.5
--
Output Ripple & Noise*
20MHz bandwidth
(peak-to-peak value)
12V/15V
--
100
--
mV
24V
--
150
--
48V
--
250
--
Temperature Coefficient
--
±0.05
--
%/
Minimum Load
0
--
--
%
Hold-up Time
230VAC
16
--
--
ms
Short Circuit Protection
Recovery time <3s after the short circuit disappear.
Constant current, continuous, self-recover
Over-current Protection
105%-150% Io, constant current mode, self-recover
Over-voltage Protection
12V
16.8V (Output voltage turn off, re-power on for
recover)
15V
24.5V (Output voltage turn off, re-power on for
recover)
24V
33.6V(Output voltage turn off, re-power on for
recover)
48V
60V (Output voltage turn off, re-power on for
recover)
Over-temperature Protection*
Over-temperature Protection Activation
--
--
85
Over-temperature Protection Deactivation
50
--
--
Remote Control
Open or 0~0.8VDC Power ON
0
--
0.8
VDC
4-10VDC Power OFF
4
--
10
Note *The “Tip and barrel method” is used for ripple and noise test, output parallel 47uF electrolytic capacitor and 0.1uF ceramic capacitor, please refer to
Enclosed Switching Power Supply Application Notes for specific information.
*Over-temperature Protection needs to be tested under rated full load conditions.
General Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Isolation
Input -
Electric Strength Test for 1min., leakage current <10mA
2000
--
--
VAC
Input-output
Electric Strength Test for 1min., leakage current <10mA
4000
--
--
output -
Electric Strength Test for 1min., leakage current <5mA
500
--
--
Insulation
Resistance
Input -
500VDC, 25±5,
Humidity < 95%RH, non-condensing
500VDC
100
--
--
MΩ
Input - output
100
--
--
output -
100
--
--
Operating Temperature
-30
--
+70
Storage Temperature
-40
--
+85
Storage Humidity
Non-condensing
10
--
95
%RH
Switching Frequency
--
--
--
kHz
Power Derating
+50 to +70℃ ℃
2
--
--
%/
-30 to -20℃ ℃
4
--
--
85VAC-100VAC
1.3
--
--
%/VAC
2000m-5000m
5
--
--
%/m
Altitude
--
--
5000
m
Safety Standard
Meet UL/EN/IEC62368/EN60335/GB4943
Safety Certification
UL/EN/IEC62368/EN60335/GB4943
Safety Class
CLASS I
MTBF
MIL-HDBK-217F@25
300,000 h
AC/DC Enclosed Switching Power Supply
LMF150-23Bxx, LMF150-23Bxx-C, LMF150-23Bxx-Q Series
2020.11.30-A/1 Page 3of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Mechanical Specifications
Case Material
Metal (AL1100, SGCC)
Dimensions
179.00 ×99.00 ×30.00mm
Weight
500g (Typ.)
Cooling Method
Free air convection
Electromagnetic Compatibility (EMC)
Emissions
CE
CISPR32/EN55032 CLASS B
RE
CISPR32/EN55032 CLASS B
Harmonic Current
IEC/EN61000-3-2 CLASS A
Voltage Flicker
IEC/EN61000-3-3
Immunity
ESD
IEC/EN 61000-4-2 Contact ±6KV /Air ±8KV
Perf. Criteria A
RS
IEC/EN 61000-4-3 10V/m
perf. Criteria B
EFT
IEC/EN 61000-4-4 ±2KV
perf. Criteria A
Surge
IEC/EN 61000-4-5 ±1KV/±2KV
perf. Criteria A
CS
IEC/EN61000-4-6 10 Vr.m.s
perf. Criteria A
DIP (AC input)
IEC/EN61000-4-11 0%, 70%
perf. Criteria B
Product Characteristic Curve
NoteWith an input voltage between 85-100VAC and a DC input between 120-140VDC the output power must be derated as per the temperature derating
curves;
This product is suitable for applications using natural air cooling; for applications in closed environment please consult Mornsun FAE.
85-305VAC
120-430VDC


Specyfikacje produktu

Marka: Dehner
Kategoria: Niesklasyfikowane
Model: LMF150-23B12

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Dehner LMF150-23B12, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Dehner

Dehner

Dehner LMF200-23B12 Instrukcja

5 Października 2024
Dehner

Dehner LMF320-23B48 Instrukcja

4 Października 2024
Dehner

Dehner LMF200-23B24 Instrukcja

4 Października 2024
Dehner

Dehner LMF320-23B24 Instrukcja

4 Października 2024
Dehner

Dehner LMF320-23B12 Instrukcja

4 Października 2024
Dehner

Dehner LMF150-23B12 Instrukcja

4 Października 2024
Dehner

Dehner LMF200-23B48 Instrukcja

4 Października 2024
Dehner

Dehner LMF150-23B24 Instrukcja

4 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024