Instrukcja obsługi Datalogic Lyn PDA Quick Start Guide

Datalogic Skaner kodów kreskowych Lyn PDA Quick Start Guide

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Datalogic Lyn PDA Quick Start Guide (2 stron) w kategorii Skaner kodów kreskowych. Ta instrukcja była pomocna dla 7 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
Lynx™ PDA Quick Start Guide
THE PACKAGE
The Lynx package includes the following items:
A) Lynx PDA
B) Quick Start Guide/ Safety and Regulatory Addendum/
Wavelink Avalanche Insert/ End User License Agreement
(EULA) Sheet
C) Rechargeable battery pack (standard @1800 mAh for Wi-Fi
models, extended @3600 mAh for HSPA+ models)
D) Power supply
E) AUS plug adapter
F) UK plug adapter
G) EU plug adapter
H) US plug adapter
I) Lanyard
J) Guitar pick stylus
K) Micro-USB cable
822001343
THE TERMINAL
A) Color display
B) ON/OFF power key
C) Receiver
D) LEDs
E) Front scan key
F) Keyboard
G) Microphone
H) Telescope stylus (not
included in the box,
please order it separately,
p/n 94ACC0068)
I) Laser safety label
J) Loudspeaker
K) Color camera
L) Flash
M) Product label (under
battery)
N) MicroSD card slot (under
battery)
O) SIM card slot (under
battery)
P) Reset key (under battery)
Q) Side scan key (right)
R) Up/down volume keys S) Side scan key (left)
T) Headset connector
U) Micro-USB port for
supplying power and data
transfer (host/slave)
V) Data capture window W) Handylink™ connector
(host/slave)
KEYPADS
Alpha-Numeric Keyboard
Numeric Keyboard
1. Call
2. End
3. Soft Key
4. Scan Key
5. Navigation Keys
6. Yellow Modifier
7. Blue Modifier
GETTING STARTED
Insert the Battery
First insert the bottom (contacts) and then the upper side of the
battery pack into the slot. Press until the battery latch clicks.
Charge the Battery
With Power Supply
Insert the micro-USB cable output plug into the micro-
USB connector of the Lynx, making sure that the
arrow on the plug faces upwards:
NOTE
With Single Slot Dock
Do not use the Lynx until standard batteries are
charged for minimum 4 hours and extended
batteries are charged for minimum 6 hours.
CAUTION
The power supply for the Single Slot Dock is included in the Single Slot
Dock box (P/N 94A150036)
Q
R
S
T
U
V W
33
1 2
4
5
6 7
3 3
12
4
5
67
E
A
B
C
D
F
G H
K
J
I
N
K
L
M
I
O
P
J
A
E
F
D
B
H
C
G
SYNCHRONIZE YOUR DEVICE WITH THE PC
Set up Synchronization using Windows Mobile®
Device Center
Windows Mobile Device Center is only compatible with Windows
Vista and Windows 7; if you run Windows XP or earlier, you have
to download Microsoft ActiveSync.
You can establish a connection to your Lynx through the
following interfaces:
USB either directly or through the Single Dock
RS232 either directly (through the Datalogic 94A051972
HandyLink™ cable) or through the Single Dock
Bluetooth®
To establish a partnership between the Lynx and a host PC, start
Windows Mobile® Device Center and follow the steps below:
1. Connect the Lynx to the host PC. Windows Mobile® Device
Center configures itself and then opens.
2. On the license agreement screen, click Accept.
3. On the Windows Mobile Device Center’s Home screen,
click Set up your device.
4. Select the information types that you want to synchronize,
then click Next.
5. Enter a device name and click Set Up.
When you finish the setup wizard, Windows Mobile Device
Center synchronizes the PDA automatically. Microsoft® Office
Outlook® emails and other information will appear on your device
after synchronization.
Communicate with Host
Insert the HandyLink™ cable output plug into the
HandyLink™ connector of the Lynx, making sure that
both the arrows on the connector and the Lynx face
upwards:
NOTE
INSTALLING A MICROSD CARD
1. Turn off the Lynx and shift the battery latch to the left and
remove the battery pack:
2. Open the card slot and insert the microSD card with the
written part downward
3. Shift the microSD card to the right to lock it into the
cardholder; close the card slot:
INSTALLING A SIM CARD
1. Turn off the Lynx and shift the battery latch to the left and
remove the battery pack:
2. Insert the SIM card with the contacts downwards:
SCANNING AND IMAGING
Laser Data Capture
Imager Data Capture
Linear barcode 2D Matrix symbol
ÌBX3ÉÎ
Relative Size and Location of Aiming System Pattern
REFERENCE DOCUMENTATION
For further information regarding Lynx refer to the SDK Help on-Line
and to the Lynx User’s Manual.
For information regarding safety and regulatory refer to the Safety
and Regulatory Addendum or to the dedicated section of the Lynx
User’s Manual.
PATENTS
This product is covered by one or more of the following patents:
Design Pat.: EP 1711946; US D633502; CN ZL201030189483.7.
Utility Patents: EP681257.
Additional patents pending.
SERVICE AND SUPPORT
Datalogic provides several services as well as technical support
through its website.
Please check our website at www.datalogic.com under “Support
& Services”, then “Automatic Data Capture”, and click on the
links indicated for further information including:
- Downloads
- Manuals for the latest versions of user manuals and
product guides.
- Software & Utilities for the latest firmware release for
your product. You can also click on the following link for
direct access to this section:
www.datalogic.com/products_updates.
- Service Program for warranty extensions and maintenance
agreements.
- Repair Centers for a list of authorised repair centers.
- Technical Support Automatic Data Capture email form to
contact our technical support.
WARRANTY TERMS AND CONDITIONS
The warranty period is 1 year for the device and 90 days for
consumables (e.g. battery, power supply, cable etc.) from date of
purchase at our company.
©2012-2013 Datalogic ADC S.r.l. • ALL RIGHTS RESERVED. •
Protected to the fullest extent under U.S. and international laws. •
Copying, or altering of this document is prohibited without express written
consent from Datalogic ADC S.r.l.
Datalogic and the Datalogic logo are registered trademarks of Datalogic
S.p.A. in many countries, including the U.S.A. and the E.U.
Lynx and the Lynx logo are trademarks of Datalogic ADC S.r.l.
All other brand and product names mentioned herein are for identification
purposes only and may be trademarks or registered trademarks of their
respective owners.


Specyfikacje produktu

Marka: Datalogic
Kategoria: Skaner kodów kreskowych
Model: Lyn PDA Quick Start Guide

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Datalogic Lyn PDA Quick Start Guide, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą