Instrukcja obsługi CyberPower Value2200ELCD

CyberPower UPS Value2200ELCD

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla CyberPower Value2200ELCD (2 stron) w kategorii UPS. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
TECHNICAL SPECIFICATIONS
Model Value600
ELCD
Value800
ELCD
Value1000
ELCD
Value1200
ELCD
Value1500
ELCD
Value2200
ELCD
Capacity (VA) 600VA 800VA 1000VA 1200VA 1500VA 2200VA
Capacity (Watts)
360W 480W 550W 720W 900W 1320W
Input
Frequency 50/60Hz(Auto Sensing)
Output
On Battery Output
Voltage Simulated Sine Wave at 230Vac +/-7%
On Battery Output
Frequency 50/60 Hz +/-1%
Overload
Protection On Utility: Circuit Breaker, On Battery: Internal Current Limiting
Physical
Total # of UPS
Receptacles 2 4
Maximum
Dimensions 140mm(H) 100mm(W) 300mm(D) 
190mm(H) 140mm(W) 326mm(D) 
Weight 4.6 kg 5.2 kg 5.6 kg 11.2 kg 13.2 kg 14.5 kg
Battery
Sealed
Maintenance Free
Lead Acid Battery
12V /
7.2Ah x1
12V / 9Ah
x1
12V / 9Ah
x1
12V / 7Ah
x2
12V /
8.5Ah x2
12V / 9Ah
x2
Typical Recharge
Time 8 Hours
Warning Diagnostics
Indicators Power On, UPS Status Display, Capacity Display, Digital Value Display
Audible Alarms On Battery, Low Battery, Overload
Environmental
Operating
Temperature 0 C to 40 C  
Operating Relative
Humidity 0 to 90%
Communication
PowerPanel®
Personal Edition
Software
Windows 7/Vista/XP/2000/Server 2003, Linux
Management
Auto-Charger Yes
Auto-Restart Yes
USB Yes
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Indication
Line mode
Select SW
Press
UPS Status Display Capacity Display Digital Value Display
Load
Cap.
Battery
Cap.
Input
Voltage
Output
Voltage
Run
Time
%
of Load
%
of Batt.
Initial V X -- X V X V
1st V X -- X V X V
2nd V X -- X V X V
3rd V X -- X X V V
4th V X -- X V X V
5th(Return) V X -- X V X V
Press >3sec
(Sound Disable) V X V X -- -- -- -- -- -- --
Press >3sec
again
(Sound Enable)
V X X X -- -- -- -- -- -- --
(Overload) V X -- V -- -- -- -- -- -- --
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
Battery mode
Select SW
Press
UPS Status Display Capacity Display Digital Value Display
Load
Cap.
Battery
Cap.
Input
Voltage
Output
Voltage
Run
Time
%
of Load
%
of Batt.
Initial X V -- X X V V
1st X V -- X X V V
2nd X V -- X V X V
3rd X V -- X X V V
4th X V -- X X V V
5th(Return) X V -- X X V V
Press >3sec
(Sound Disable) X V V X -- -- -- -- -- -- --
Press >3sec
again
(Sound Enable)
X V X X -- -- -- -- -- -- --
(Overload) X V -- V -- -- -- -- -- -- --
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
CYBERPOWER GREENPOWER UPS™ TECHNOLOGY
CyberPower’s Green Commitment
CyberPower is dedicated to the development of green products, and has adopted
Green practices throughout its business, including: membership in Climate Savers
Computing Initiative (CSCI), accordance with the Restriction on Hazardous
Substances (RoHS), Waste Electrical and Electronic Equipment (WEEE) protocols,
as well as ISO 14001 and IECQ QC080000. CyberPower pledges to provide the
advanced energy solution for the environment and become a leading eco-friendly
organization in the UPS industry.
Reduce Energy Cost with GreenPower UPSTM Technology
CyberPower’s goal is not only to provide eco-friendly products but also to bring the best value for
consumers. The advanced energy-saving design improves the operating efficiency and eliminates
waste energy consumption As a result, consumers will enjoy significant energy cost savings with the .
adoption of GreenPower UPSTM technology.
TROUBLE SHOOTING
Problem Possible Cause Solution
The UPS does
not perform
expected
runtime.
Batteries are not fully charged.
Recharge the battery by leaving the UPS
plugged in.
Battery is slightly worn out. Contact CyberPower Systems Technical
Support.
The UPS will not
turn on.
The on/off switch is designed
to prevent damage by rapidly
turning it off and on.
Turn the UPS off. Wait 10 seconds and then
turn the UPS on.
The unit is not connected to an
AC outlet.
The unit must be connected to a 220-240V
50/60Hz outlet.
The battery is worn out. Contact CyberPower Systems Technical
Support.
Mechanical problem. Contact CyberPower Systems Technical
Support.
Outlets do not
provide power to
equipment
Circuit breaker is tripped due
to overload
Turn the UPS off and unplug at least one
piece connected equipment. Unplug the
power cord of the UPS then press the circuit
breaker knob.
Batteries are discharged Allow the unit to recharge for at least 4
hours.
Unit has been damaged by a
surge or spike.
Contact CyberPower Systems Technical
Support.
PowerPanel®
Personal Edition
is inactive
The serial/USB cable is not
connected.
Connect the serial/USB cable to the UPS
unit and an open serial port on the back of
the computer. You must use the cable that
came with the unit.
The unit is not providing
battery power.
Shutdown your computer and turn the UPS
off. Wait 10 seconds and turn the UPS back
on. This should reset the unit.
For more information, visit www.cyberpower.com
All rights reserved. Reproduction without permission is prohibited.
11F., No.26, Jinzhuang Rd., Neihu Dist., Taipei City 114, Taiwan


Specyfikacje produktu

Marka: CyberPower
Kategoria: UPS
Model: Value2200ELCD

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z CyberPower Value2200ELCD, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje UPS CyberPower

CyberPower

CyberPower SM180KMFX Instrukcja

9 Października 2024
CyberPower

CyberPower RT33030KE Instrukcja

9 Października 2024
CyberPower

CyberPower SM300KMFX Instrukcja

9 Października 2024
CyberPower

CyberPower OLS3S20KEXL Instrukcja

9 Października 2024
CyberPower

CyberPower UT1050EI Instrukcja

9 Października 2024
CyberPower

CyberPower BU600E Instrukcja

9 Października 2024
CyberPower

CyberPower VP700ELCD Instrukcja

9 Października 2024
CyberPower

CyberPower VP1000ELCD Instrukcja

9 Października 2024

Instrukcje UPS

Najnowsze instrukcje dla UPS

APC

APC Back-UPS BN575G Instrukcja

12 Października 2024
APC

APC Smart-UPS SMC1000-2UC Instrukcja

12 Października 2024
APC

APC Back-UPS BX550CI-AR Instrukcja

12 Października 2024
APC

APC Back-UPS BN600G Instrukcja

12 Października 2024
APC

APC Back-UPS BX650CI-GR Instrukcja

12 Października 2024
APC

APC Back-UPS BX950U-FR Instrukcja

12 Października 2024
APC

APC Back-UPS BX650LI Instrukcja

12 Października 2024
APC

APC Easy UPS BVX1000UXI Instrukcja

12 Października 2024
Eaton

Eaton EX 3000VA 3U XL Instrukcja

11 Października 2024