Instrukcja obsługi CyberPower CPS1500PIE
CyberPower
UPS
CPS1500PIE
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla CyberPower CPS1500PIE (19 stron) w kategorii UPS. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/19
User’s Manual
CPS1500PIE
K01-0000133-03
EN
CyberPower Systems, Inc.
Website: www.cpsww.com
CPS15 PIE 00
Copyright © 20 CyberPower Systems, Inc.14
1
SAFETY AND EMC INSTRUCTIONS
Safety and EMC instructions
This manual contains important safety instructions. Please read and follow all instructions carefully during
installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or
operate your Emergency Power System (EPS).
CAUTION! To prevent the risk of re or electric shock, install in a temperature and humidity
controlled indoor area free of conductive contaminants. (Please see specications for acceptable
temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover.
CAUTION! EPS must be connected to an AC power outlet with circuit breaker protection. Do not
plug into an outlet that is not grounded. If you need to de-energize this equipment, turn o and unplug the
unit.
CAUTION! To avoid electrical shock, turn o the unit and unplug it from the AC power source before
servicing EPS, replacing the external battery or installing equipment.
CAUTION! To reduce the risk of re, only connect the EPS to a circuit with 16 amperes
( maximum branch circuit over-current protection in accordance with the CE
CPS 00PIE15 Series)
requirement.
CPS 00PIE Series include CPS1500PIE CPS 00PIE- CPS 00PIE-UK and other versions. 15 , 15 FR, 15
CAUTION! The building wiring socket outlet (shockproof socket outlet) must be easily accessible
and close to the EPS.
CAUTION! Please use only VDE-tested, CE-marked mains cable (e.g. the mains cable of your
equipment) to connect the EPS to the building wiring socket outlet (shockproof socket outlet).
CAUTION! Please use only VDE-tested, CE-marked power cables to connect the loads to the EPS.
CAUTION! When installing the equipment, ensure that the sum of the leakage current of the EPS
and the connected equipment does not exceed 3.5mA.
CAUTION! This is permanently connected equipment and only qualied maintenance personnel
may carry out installations.
CAUTION! Do not disconnect the mains cable on the EPS or the building wiring socket outlet
(shockproof socket outlet) during operations since this would remove the protective ground of the EPS
and of all connected loads.
CAUTION! The EPS shall be connected to the emergency switching device.
CPS1500PIE
Copyright © 20 CyberPower Systems, Inc.14
2
DO NOT USE FOR MEDICAL SUPPORT EQUIPMENT!OR LIFE DO NOT use in
any circumstance that would aect operation or safety of any life support equipment or with any medical
applications or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of re or electric shock,
do not use with or near an aquarium. Condensation from the aquarium can cause the unit to short out.
DO NOT USE WITH LASER PRINTERS! The power demands of these devices will
overload and possibly damage the unit.
DO NOT INSTALL THE EPS WHERE IT WOULD BE EXPOSED TO DIRECT
SUNLIGHT OR NEAR HEAT!
DO NOT BLOCK OFF VENTILATION OPENINGS IN THE EPS HOUSING! ’S
DO NOT CONNECT DOMESTIC APPLIANCES SUCH AS HAIR DRYERS TO
EPS OUTPUT SOCKETS.
SAFETY:
EN62040-1- 1
EMI:
Conducted Emissi IEC/EN 62040-2 Category C2 on: …
Radiated Emission: IEC/EN 62040-2 Category C2 ……
Harmonic Current: IEC/EN61000-3-2
Voltage Fluctuations and Flicker: IEC/EN61000-3-3
EMS:
IEC/EN61000-4-2(ESD)
IEC/EN61000-4-3(RS)
IEC/EN61000-4-4(EFT)
IEC/EN61000-4-5(lightning surge)
IEC/EN61000-4-6(CS)
IEC/EN61000-4-8(Magnetic)
IEC/EN61000-2-2 (Immunity to low frequency signals)
Specyfikacje produktu
Marka: | CyberPower |
Kategoria: | UPS |
Model: | CPS1500PIE |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z CyberPower CPS1500PIE, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje UPS CyberPower
3 Stycznia 2025
3 Stycznia 2025
30 Grudnia 2025
8 Grudnia 2024
8 Grudnia 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
Instrukcje UPS
- UPS Ikea
- UPS AEG
- UPS Lenovo
- UPS Voltcraft
- UPS LC-Power
- UPS Conceptronic
- UPS Siemens
- UPS APC
- UPS Tripp Lite
- UPS Block
- UPS Gembird
- UPS V7
- UPS Digitus
- UPS FSP
- UPS GYS
- UPS Online USV
- UPS Equip
- UPS Emerson
- UPS JUNG
- UPS Eaton
- UPS Adj
- UPS PowerWalker
- UPS Salicru
- UPS Energenie
- UPS Steren
- UPS East
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Furman
- UPS Minuteman
- UPS Riello
- UPS Maruson
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Approx
- UPS Altronix
- UPS Bxterra
- UPS Middle Atlantic
- UPS Atlantis Land
- UPS FSP/Fortron
Najnowsze instrukcje dla UPS
1 Stycznia 2025
31 Grudnia 2025
31 Grudnia 2025
30 Grudnia 2025
29 Grudnia 2024
28 Grudnia 2024
28 Grudnia 2024
28 Grudnia 2024
14 Grudnia 2024
14 Grudnia 2024