Instrukcja obsługi CyberPower OLS6000ECXL

CyberPower UPS OLS6000ECXL

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla CyberPower OLS6000ECXL (24 stron) w kategorii UPS. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/24
Userˊ
ˊ
ˊ
ˊˊs Manual
OLS6000EC(XL)
OLS10200 (XL) EC
CyberPower Systems Inc.
www.cyberpower.com
K01-C000829-00
1
1. Safety
Please read carefully the following user manual and the safety instructions
before installing the unit or using the unit!
1.1. Installation
This is permanently connected equipment, and it must be installed by qualified
maintenance personnel.
Condensation may occur if the UPS is moved directly from a cold to a warm
environment. The UPS must be absolutely dry before being installed. Please
allow an acclimatization time of at least two hours.
Do not install the UPS near water or in damp environment.
Do not install the UPS where it would be exposed to direct sunlight or near heat.
Do not connect appliances or items of equipment which would overload the UPS
(e.g. laser printers, etc.) to the UPS output.
Do not block ventilation openings in the UPS’s housing. Ensure allow at least
0.5m of space on front and rear of the UPS.
Place cables in such a way that no one can step on or trip over them.
Connect UPS with the earth reliably before connecting to the building wiring
terminal, and external battery source must also be earthed.
An integral single emergency switching device which prevents further supply to
the load by the UPS in any mode of operation should be provided in the building
wiring installation.
An appropriate disconnect device as short-circuit backup protection should be
provided in the building wiring installation.
The equipment is powered by two sources: the mains source, the internal
battery or the external battery source.
With the installation of the equipment, the sum of the leakage current of the UPS
and the connected load does not exceed 5% of rated value of input current.
1.2. Operation
Do not disconnect the main cable on the UPS or the building wiring terminals
during operation since this would remove the protective earth from the UPS and
all connected loads.
The UPS output terminal block may still be electrically lived even if the UPS is
2
not connected to the building wiring terminal for there is internal current source ,
(batteries).
In order to fully disconnect the UPS, first turn the input breaker in the "OFF"
position, then disconnect the mains lead.
Indiscriminate operation of switches may cause output loss or damage to
equipment. Refer to instruction before conducting any control.
While the UPS work as a parallel system, the external parallel cable should be
reinforced insulation.
Ensure that no liquid or other foreign objects can enter the UPS.
1.3. Maintenance, Servicing and Faults
Do not remove the enclosure since the UPS operates with hazardous voltages.
It is to be serviced only by qualified maintenance personnel.
Risk of electric shock. Even after the unit is disconnected from the Caution!
mains power supply (building wiring terminal) components inside the UPS are
still connected to the battery which are potentially dangerous.
Before carrying out any kind of service or maintenance, isolate UPS and
disconnect the batteries. Verify that no current is present and no hazardous
voltage exists in the capacitor or BUS capacitor.
Batteries must be replaced only by qualified personnel.
Batteries have a high short-circuit current and pose a risk of shock. Take all
precautionary measures specified below and any other necessary measures
when working with batteries:
─ remove all jewellery, wristwatches, rings and other metal objects
─ use only tools with insulated grips and handles.
When changing batteries, replace with the same quantity and the same type of
batteries.
Do not attempt to dispose of batteries by burning them. It could cause explosion.
The UPS may be connected to external battery package. Proper disposal of
batteries is required. Refer to your local codes for disposal requirements.
Do not open or destroy batteries. Effluent electrolyte can cause injury to the skin
and eyes. It may be toxic.
Replace the fuse only by a fuse of the same type and of the same spec in order
to avoid fire hazards.


Specyfikacje produktu

Marka: CyberPower
Kategoria: UPS
Model: OLS6000ECXL

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z CyberPower OLS6000ECXL, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje UPS CyberPower

CyberPower

CyberPower SM180KMFX Instrukcja

9 Października 2024
CyberPower

CyberPower RT33030KE Instrukcja

9 Października 2024
CyberPower

CyberPower SM300KMFX Instrukcja

9 Października 2024
CyberPower

CyberPower OLS3S20KEXL Instrukcja

9 Października 2024
CyberPower

CyberPower UT1050EI Instrukcja

9 Października 2024
CyberPower

CyberPower BU600E Instrukcja

9 Października 2024
CyberPower

CyberPower VP700ELCD Instrukcja

9 Października 2024
CyberPower

CyberPower VP1000ELCD Instrukcja

9 Października 2024

Instrukcje UPS

Najnowsze instrukcje dla UPS

APC

APC Back-UPS BN575G Instrukcja

12 Października 2024
APC

APC Smart-UPS SMC1000-2UC Instrukcja

12 Października 2024
APC

APC Back-UPS BX550CI-AR Instrukcja

12 Października 2024
APC

APC Back-UPS BN600G Instrukcja

12 Października 2024
APC

APC Back-UPS BX650CI-GR Instrukcja

12 Października 2024
APC

APC Back-UPS BX950U-FR Instrukcja

12 Października 2024
APC

APC Back-UPS BX650LI Instrukcja

12 Października 2024
APC

APC Easy UPS BVX1000UXI Instrukcja

12 Października 2024
Eaton

Eaton EX 3000VA 3U XL Instrukcja

11 Października 2024