User Manual for
CPS825AVR with USB Interface and
PowerPanel Plus™ Software
ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:
www.cyberpowersystems.com/faqs.htm
TABLE OF CONTENTS
Thank you for purchasing a CyberPower Systems Product. To enjoy all the features and benefits of this
Uninterruptible Power System (UPS), please read and follow all installation and operation instructions completely.
This UPS is designed to provide guaranteed power protection for connected electronic equipment. The accompanying
PowerPanel Plus™ software saves data, closes open applications and automatically shuts down your computer
system in an intelligent and orderly manner.
IMPORTANT SAFETY INSTRUCTIONS
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of unit. Read this manual thoroughly before attempting to install or
operate.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled
indoor area, free of conductive contaminants. (Please see specifications for acceptable temperature and
humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover secured by star shaped screws. No
user serviceable parts are inside except for the battery. Refer servicing to qualified personnel.
CAUTION! The battery can energize hazardous live parts inside even when the AC input power is
disconnected.
CAUTION! UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not
plug into an outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the unit.
CAUTION! To avoid electrical shock, turn off the unit and unplug it from the AC power source before
servicing the battery or installing a computer component.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell
products for life support or medical applications or for use in any circumstance that would affect operation or
safety of any medical for life support or medical applications or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire, do not use with or near
aquariums. Condensation from the aquarium can cause the unit to short out.
WHAT IS AVR?
This machine provides complete power protection from
utility power that is not always consistent. The
CPS825AVR features a high level of surge suppression
(1260 Joules) for power line surges, and provides long
lasting battery backup with dual 7.2AH batteries for
loss of utility power and voltage sags. The
CPS825AVR ensures consistent power to your
computer system and includes software that will
automatically save your open files and shutdown your
computer system during a utility power loss.
AUTOMATIC VOLTAGE REGULATOR
The CPS825AVR controls utility power voltage levels that can be inconsistent. The incoming utility power may be at a damaging
level to important data files, but with the Automatic Voltage Regulation of the CPS825AVR the computer will only experience a
consistent voltage level. An Automatic Voltage Regulator automatically increases low or decreases high voltage to a consistent,
computer safe 110v/120v. The powerful dual 7.2AH batteries provide power only if the incoming voltage drops below 85v or
increases above 150v.
Description ----------------------------------------------- 1
Determining Power Requirements 1
Hardware Installation Guide ------------------------- 2
Software Installation Guide -------------------------- 2
Software User Manual -------------------------------- 3
Battery Replacement--------------------------------------8
LED Indicators --------------------------------------------9
Trouble Shooting Guide-------------------------------- 10
Specifications -------------------------------------------- 10
Warranty-------------------------------------------------- 11
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Make sure that the total Volt-Amp (VA) requirements of your computer; monitor and peripheral
equipment does not exceed 1440VA.
2. Insure that the equipment plugged into the three battery power-supplied outlets does not exceed the
UPS unit’s rated capacity (825VA/410W for CPS825AVR). If rated unit capacities are exceeded, an
overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
3. If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert Watts
(W) or Amps (A) into VA by doing the calculations below. Note: The below equation only calculates the
maximum amount of VA that the equipment can use, not what is typically used by the equipment at any
one time. Users should expect usage requirements to be approximately 60% of below value.
TO ESTIMATE POWER REQUIREMENTS:
Watts (W) x 2.0 = VA or Amps (A) x 120 = VA
Add the totals up for all pieces of equipment and multiply this total by .6 to calculate actual requirements There
are many factors that can affect the amount of power that your computer system will require. The total load that
you will be placing on the battery-powered outlets should not exceed 80% of the unit’s capacity.
INSPECTION
The box should contain the following:
(1) PowerPanel Plus™ software (floppy disk); (1) serial interface cable (DB-9); (1) serial to USB adapter cable; (1)
telephone communication cable; (1) user manual; (1) warranty registration card; (1) UPS unit.
DESCRIPTION
5. Power Switch
Can be used as the master on/off switch for
computer equipment connected to the battery
power supplied outlets.
6. Power On Indicator
This LED is illuminated when the utility condition
is normal and the UPS outlets are providing
“clean” power, free of surges and spikes.
7. Electrical Wiring Fault Indicator
This LED indicator will illuminate to warn the user
that a wiring problem exists with the AC outlet.
If this LED is illuminated, user is advised to
unplug all electrical equipment from the outlet
and have an electrician check the outlet to insure
proper wiring.
8. Communication Protection Ports
Communication protection ports will protect any
standard modem, fax, or telephone line.
9. Serial Port to PC
This port allows connection and
communication from the DB-9 serial or USB port
on the computer to the UPS unit. The UPS
communicates its status to the PowerPanel
Plus™ software. This interface is also
compatible with the UPS service provided by
Windows NT, Windows 2000 and Windows XP.
1. Battery Backup and Surge Protection Outlets
Provides three battery-supplied outlets with
A
utomatic Voltage Regulation for consistent output
power to connected equipment.
2. “Always-On” Surge Protection Outlets
Provides three surge-protected outlets to protect
connected equipment against surges and spikes.
3. All outlets Designed for AC Adapters
A
llows six AC power adapter blocks to be plugged
into the UPS without making adjacent outlets
inaccessible.
4. Resettable Circuit Breaker
Located on the side of the UPS, the circuit breaker
provides circuit overload and fault protection.
Under normal operating conditions, the circuit
breaker is depressed.
Specyfikacje produktu
Marka: | CyberPower |
Kategoria: | UPS |
Model: | CPS825AVR |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z CyberPower CPS825AVR, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje UPS CyberPower
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
Instrukcje UPS
- UPS Ikea
- UPS AEG
- UPS Voltcraft
- UPS LC-Power
- UPS APC
- UPS Tripp Lite
- UPS Block
- UPS V7
- UPS Digitus
- UPS FSP
- UPS Online USV
- UPS Equip
- UPS Emerson
- UPS JUNG
- UPS Eaton
- UPS Adj
- UPS PowerWalker
- UPS Salicru
- UPS Energenie
- UPS Steren
- UPS East
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Furman
- UPS Minuteman
- UPS Riello
- UPS Maruson
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Approx
- UPS Altronix
- UPS Bxterra
- UPS Middle Atlantic
- UPS Atlantis Land
- UPS FSP/Fortron
Najnowsze instrukcje dla UPS
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
11 Października 2024
9 Października 2024