Instrukcja obsługi CyberPower CPS600E
CyberPower
UPS
CPS600E
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla CyberPower CPS600E (44 stron) w kategorii UPS. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/44
K01-0000208-02
CPS600E-DE
User’s Manual
2
SAFETY AND EMC INSTRUCTIONS
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of the unit. Read this manual thoroughly before attempting to unpack,
install, or operate your Emergency Power System (EPS).
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled
indoor area free of conductive contaminants. (Please see specifications for acceptable temperature
and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover, except to service the battery.
There are no serviceable parts inside, except for the battery.
CAUTION! EPS must be connected to an AC power outlet with circuit breaker protection. Do not plug
into an outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the
unit.
CAUTION! To avoid electrical shock, turn off the unit and unplug it from the AC power source before
servicing EPS, replacing the external battery or installing equipment.
CAUTION! To reduce the risk of fire, only connect the EPS to a circuit with 10 amperes maximum
branch circuit over-current protection in accordance with the CE requirement.
CAUTION! The building wiring socket outlet (shockproof socket outlet) must be easily accessible and
close to the EPS.
CAUTION! Please use only VDE-tested, CE-marked mains cable (e.g. the mains cable of your
equipment) to connect the EPS to the building wiring socket outlet (shockproof socket outlet).
CAUTION! Please use only VDE-tested, CE-marked power cables to connect the loads to the EPS.
CAUTION! When installing the equipment, ensure that the sum of the leakage current of the EPS and
the connected equipment does not exceed 3.5mA.
CAUTION! Do not disconnect the mains cable on the EPS or the building wiring socket outlet
(shockproof socket outlet) during operations since this would remove the protective ground of the EPS
and of all connected loads.
CAUTION! This is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!
DO NOT use in any circumstance that would affect operation and safety of any life support equipment,
any medical applications or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use
with or near an aquarium. Condensation from the aquarium can cause the unit to short out.
DO NOT INSTALL THE EPS WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR
HEAT!
DO NOT BLOCK OFF VENTILATION OPENINGS IN THE EPS’S HOUSING!
SAFETY:
EN62040-1-1
EMI:
Conducted Emission: IEC/EN 62040-2…Category C2
Radiated Emission: IEC/EN 62040-2……Category C2
Harmonic Current: IEC/EN61000-3-2
Voltage Fluctuations and Flicker: IEC/EN61000-3-3
3
EMS:
IEC/EN61000-4-2(ESD)
IEC/EN61000-4-3(RS)
IEC/EN61000-4-4(EFT)
IEC/EN61000-4-5(lightning surge)
IEC/EN61000-2-2 (Immunity to low frequency signals)
INSTALLING YOUR EPS
UNPACKING
Inspect the EPS upon receipt. The box should contain the following:
(1) EPS Unit x 1; (2) User Manual x 1; (3) Input Power Cord x 1; (4) DC Fuse x 2
AUTOMATIC VOLTAGE REGULATOR
Utility power is inconsistent. The EPS increases low voltage to computer safe 230 volts. The EPS
automatically provides battery backup (External battery connection required) if the voltage drops below
170 volts or exceeds 270 volts.
HARDWARE INSTALLATION GUIDE
1. Your new EPS may be used immediately upon receipt. However, recharging the external battery
for at least 8 hours is recommended to ensure that the battery’s maximum charge capacity is
achieved. To recharge the external battery, simply leave the unit plugged into an AC outlet when
EPS is ON.
2. DO NOT use with medical or life support equipment. DO NOT use with or near aquariums
as condensation may cause the unit to short out.
3. After connecting the hard wires, plug the EPS into a 2 pole, 3 wire grounded receptacle (wall
outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not
service equipment with large electrical demands (e.g. air conditioner, copier, etc…). The warranty
prohibits the use of extension cords, outlet strips, and surge strips.
4. Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit
will beep once.
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To
correct this, turn the EPS off and unplug the equipment from the AC outlet. Ensure that the
equipment plugged into the outlet does not exceed the UPS unit’s rated capacity (600VA/420W for
CPS600E-DE). If the rated capacities of the unit are exceeded, an overload condition may occur
and cause the UPS unit to shut down or the input fuse to blow. For more information, refer to the
“Troubleshooting” section.
6. To maintain optimum battery charge performance, make the EPS plugged into an AC outlet at all
times.
7. The UPS is designed for horizontal or wall-mount use only. To ensure safety, please follow the
placement directions as shown below.
Specyfikacje produktu
Marka: | CyberPower |
Kategoria: | UPS |
Model: | CPS600E |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z CyberPower CPS600E, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje UPS CyberPower
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
Instrukcje UPS
- UPS Ikea
- UPS AEG
- UPS Voltcraft
- UPS LC-Power
- UPS APC
- UPS Tripp Lite
- UPS Block
- UPS V7
- UPS Digitus
- UPS FSP
- UPS Online USV
- UPS Equip
- UPS Emerson
- UPS JUNG
- UPS Eaton
- UPS Adj
- UPS PowerWalker
- UPS Salicru
- UPS Energenie
- UPS Steren
- UPS East
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Furman
- UPS Minuteman
- UPS Riello
- UPS Maruson
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Approx
- UPS Altronix
- UPS Bxterra
- UPS Middle Atlantic
- UPS Atlantis Land
- UPS FSP/Fortron
Najnowsze instrukcje dla UPS
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
12 Października 2024
11 Października 2024
9 Października 2024