160 User Guide
AC Mobile Power Inverter
CPS160PPB2U Specifications
Troubleshooting
Fuse Replacement
Important Safety Information
Package Contents
Product Features
AC Mobile Power Inverter
• User Guide
1. Unplug the inverter from the DC power outlet.
2. Disassemble the DC plug as pictured below.
3. Replace the 15 amp fuse.
4. Reassemble the DC plug as pictured below.
Input Voltage 11 to 15 volts
Output Peak Power 160 Watts
Output Continuous Power 100 Watts
Output Voltage 120 Volts / USB 5 Volts
Output Frequency 60 Hz
Output Waveform Simulated Sine Wave
Protection Features Low Voltage, Overheat,
Overload, Short Circuit
Problem
No AC output power Poor contact with DC power
outlet.
Automotive electrical system
requires ignition to be on.
Car's DC power outlet fuse is
blown.
Over-heating.
Vehicle's battery voltage is
below 11 volts.
Vehicle's battery input voltage
is higher than 15 volts.
Inverter is overloaded.
Ensure the inverter is securely plugged
into vehicle's DC power outlet. Replace
the DC power outlet if necessary.
Turn the vehicle ignition to the
"Accessory" position.
Check the vehicle fuse panel and
replace the damaged fuse.
Allow inverter to cool. Ensure that there
is adequate ventilation around the unit
and load does not exceed the unit's
Continuous Power rating (see
specifications).
Unplug the inverter and start the vehicle
to charge the battery.
Check your vehicle's user guide for
troubleshooting.
Ensure load does not exceed the unit's
Continuous Power rating (see
specifications).
Suggested SolutionsPossible Cause
Before installing and using the CyberPower Mobile Power Inverter
please read and follow these safety instructions:
• Moderate Temperature - Ambient air temperature should be between
32oF - 104oF (0oC - 40oC). Keep the inverter out of direct sunlight.
• Free Air Flow - Keep the inverter's ventilation slots unobstructed to ensure
air flow to the unit. Do not place any items on or over the inverter during
operation. The unit will shut down if it overheats.
Storage Tips
• Proper storage temperature range is 32
oF - 122oF (0oC - 50oC)
• Store and use the inverter in a cool and dry environment.
Avoid exposing the inverter to heating elements, direct sunlight, or high
humidity.
Operating and Storage Tips
Operating Tips
The inverter should only be operated under the following conditions:
• Dry - Do not allow water or other liquids to come into contact with the
inverter.
• Do not operate the CPS160PPB2U near flammable materials, fumes, or
gases.
Always use the inverter where there is adequate ventilation. Do not
obstruct the ventilation slots.
• Never immerse the unit in water.
• Proper cooling is essential when operating the inverter. Refrain from
placing the inverter near the vehicle's heat vent, or in direct sunlight.
Always turn the inverter off when not in use by removing it from the DC
accessory socket.
• Check the warning labels on battery chargers or adapters before
connecting them to the inverter. Do not connect battery chargers or
adapters with warnings about using with inverters.
Cy Power S tems (USA) I .ber ys , nc
4241 12 enue 400 ha opee 5537 th Av Eas Suite t, , S k , MN 9
TEL: ( ) -952 403 9500 To -Frll ee 877: ( ) - 7297 693
FAX: (952 403) -0009 E-ma : sales@cps .comil ww
www.cyberpower.com
C 2017 Cy Power S temsber ys , I .nc
All righ ed ep oduts reserv . R r ction in w le or in rt wit t rmiho pa hou pe ssion is p rohibit .ed
K01-0000378-02
Limited Warranty
Product Registration
Technical Support
Legal notices (FCC Part 15)
CyberPower warrants this CPS160PPB2U (the "Inverter") to be free from material
and manufacturing defects for two years. If a defect results in product failure during its
normal use, CyberPower’s sole responsibility is to repair or replace (at its sole option)
the Inverter.
The foregoing Limited Warranty is the consumer’s sole and exclusive remedy and
excludes any incidental or consequential damages. Some States do not allow the
exclusion or limitation of incidental and consequential damages, so certain of the
above limitations or exclusions may not apply to you (the Consumer). This limited
warranty gives the Consumer specific legal rights and the Consumer may have other
rights, which vary from State to State.
To make a Limited Warranty claim:
1. Pack and ship the Inverter to CyberPower at 4241 12th Avenue East, Suite 400,
Shakopee, MN 55379.
2. Clearly indicate on the outside of the packaging that this is a “WARRANTY
RETURN”
3. Clearly include your name and address (a) on the outside packaging and (b) on a
sheet of paper enclosed in the box with the Inverter that is being returned.
4. You MUST prepay all shipping costs and you are responsible for packaging and
shipment.
CAUTION: Any changes or modifications not expressly approved by the guarantee
of this device could void the user’s authority to operate the equipment.
Thank you for purchasing a CyberPower product. Prompt product registration entitles
coverage under the Limited Warranty and also allows the opportunity to be notified of
product enhancements, upgrades, and other announcements.
Registration is quick and easy. Go to Product Registration page at
www.cyberpower.com
Feel free to contact our Tech Support department with installation, troubleshooting, or
general product questions.
CyberPower Technical Support
Phone: 1-877-297-6937
Email: tech@cpsww.com
Web: www.cyberpower.com
Address: 4241 12th Ave. E., STE 400, Shakopee, MN 55379
Hours of Operation: Monday – Friday, 7:00am – 6:00pm (CST)
This equipment has been tested and found to comply with the limits for a Class B Digital Device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the
equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected. (4) Consult the dealer or an experienced radio/TV technician for
help. Any special accessories needed for compliance must be specified in the instruction.
CAUTION: A shielded-type power cord is required in order to meet FCC emission limits and
also to prevent interference to the nearby radio and television reception. It is essential that only the
supplied power cord be used. Use only shielded cables to connect I/O devices to this equipment.
Spring
Ring
Contact Pin
Contact Retainer
15A Fuse
Power plug
1. 12V power plug
2. USB charging ports
(2.1 AMPS)
3. Cooling Fan
4. 120V AC outlet
5. Seat clip
6. Child safety covers
1
2
6
3
4
5


Specyfikacje produktu

Marka: CyberPower
Kategoria: Akumulator
Model: CPS160PPB2U

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z CyberPower CPS160PPB2U, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Akumulator CyberPower

Instrukcje Akumulator

Najnowsze instrukcje dla Akumulator

Anova

Anova VAR3030 Instrukcja

8 Października 2024
Valcom

Valcom VBB-1424 Instrukcja

8 Października 2024
TOA

TOA BP-920 Instrukcja

8 Października 2024
Vonroc

Vonroc S_CF501DC Instrukcja

8 Października 2024
DeWalt

DeWalt DCB547 Instrukcja

8 Października 2024
PowerPlus

PowerPlus POWDP9038 Instrukcja

8 Października 2024
PowerPlus

PowerPlus POWDP9022 Instrukcja

8 Października 2024
Hilti

Hilti C 4/36 MC4 Instrukcja

8 Października 2024