Instrukcja obsługi CyberPower CP1500AVRLCDTAA

CyberPower UPS CP1500AVRLCDTAA

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla CyberPower CP1500AVRLCDTAA (10 stron) w kategorii UPS. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/10
INTELLIGENT UPS SERIES
CP850/1000/1350/1500AVRLCD
USER MANUAL
YOUR ULTIMATE ALLY IN POWER
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379 | CyberPowerSystems.com
FEATURES
1. Power Switch
2. Power On Indicator
3. LCD Module Display
4. Display/Select Button
5. Mute/Enter Button
6. Battery and Surge Protected Outlets
7. Full-Time Surge Protection Outlets
8. Circuit Breaker
9. DB9/USB Ports
10. Communication Protection Ports
11. Wiring Fault Indicator (red)
12. Coax/Cable/DSS Surge Protection
13. Widely-spaced Outlets
CP850/1000A LCVR D CP RLCD1350AV CP1500A LCVR D
12
3
45
12
9
11
8
10
6
7
10
9
11
1313
1313
8
12
6 7
12
9
11
8
10
67
Thank you for purchasing a CyberPower product. This UPS is designed to provide unsurpassed
power protection, operation, and performance during the lifetime of the product. Please take a
few minutes to register your product at: www.CyberPowerSystems.com/registration.
Registration certifies your product’s warranty, confirms your ownership in the event of a
product loss or theft, and entitles you to free technical support. Register your product now to
receive the benefits of CyberPower ownership.
CAUTION! To prevent the risk of fire or
electric shock, install in a temperature and
humidity controlled indoor area free of
conductive contaminants. (Please see
specifications for acceptable temperature
and humidity range).
CAUTION! To reduce the risk of electric shock,
do not remove the cover except to service the
battery. Turn o and unplug the unit before
servicing the batteries. There are no user ser-
viceable parts inside except for the battery.
CAUTION! Hazardous live parts inside can be
energized by the battery even when the AC
input power is disconnected.
CAUTION! The UPS must be connected to an
AC power outlet with fuse or circuit breaker
protection. Do not plug into an outlet that is
not grounded. If you need to de-energize this
equipment, turn o and unplug the unit.
CAUTION! To avoid electric shock, turn o the
unit and unplug it from the AC power source
before installing a computer component.
CAUTION! To reduce the risk of fire, connect
only to a circuit provided with 20 amperes
maximum branch circuit over current protec-
tion in accordance with the National Electric
Code, ANSI/NFPA 70.
CAUTION! Not for use in a computer room as
defined in the Standard for the Protection of
Electronic Computer/Data Processing Equip-
ment, ANSI/NFPA 75.
CAUTION! Do not dispose of batteries in a
fire. The batteries may explode.
CAUTION! Do not open or mutilate batteries.
Released electrolyte is harmful to the skin and
eyes. It may be toxic.
DO NOT USE FOR MEDICAL
OR LIFE SUPPORT EQUIPMENT!
CyberPower Systems does not sell products
for life support or medical applications. DO
NOT use in any circumstance that would
aect operation and safety of life support
equipment, any medical applications or pa-
tient care.
DO NOT USE WITH OR NEAR AQUARIUMS!
To reduce the risk of fire or electric shock, do
not use with or near an aquarium. Condensa-
tion from the aquarium can cause the unit to
short out.
DO NOT USE THE UPS
ON ANY TRANSPORTATION!
To reduce the risk of fire or electric shock, do
not use the unit on any transportation such
as airplanes or ships. The eect of shock or
vibration caused during transit and the damp
environment can cause the unit to short out.
PRODUCT REGISTRATION
IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of the unit. Read this manual thoroughly before attempting to
unpack, install, or operate your UPS.
INSTALLING YOUR UPS SYSTEM
UNPACKING
Inspect the UPS upon receipt.
The box should contain the following:
(a) UPS unit
(b) User’s manual
(c) USB A+B type cable
(d) Function Setup Guide
PowerPanel® Personal software is available
on our website. Please visit www.cyberpower-
systems.com and go to the Software Section
for a free download.
OVERVIEW
The CP850/1000/1350/1500AVRLCD provides
complete power protection from utility power
that is not always consistent.
The CP850/1000AVRLCD features 1080 Joules
and the CP1350/1500AVRLCD features 1500
Joules of surge protection.
The unit provides long lasting battery backup
during power outages with maintenance free
batteries.
The CP850/1000/1350/1500AVRLCD ensures
consistent power to your computer system
and includes software that will automatically
shut down your computer system during a
utility power loss.
AUTOMATIC VOLTAGE REGULATOR
The CP850/1000/1350/1500AVRLCD stabiliz-
es inconsistent utility power to nominal levels
that are safe for equipment. Unstable utility
power can be damaging to important data and
hardware. With Automatic
Voltage Regulation (AVR),
damaging voltage levels
are corrected to safe
levels. AVR automatically
increases low utility power
to a consistent and safe
110/120 volts.
DETERMINE THE POWER
REQUIREMENTS OF YOUR EQUIPMENT
1. Ensure that the equipment plugged into
the UPS does not exceed the UPS unit’s
rated capacity. If the rated capacities of the
unit are exceeded, an overload condition
may occur and cause the UPS unit to shut
down or the circuit breaker to trip.
2. There are many factors that can aect
the amount of power that your electronic
equipment will require. For optimal system
performance keep the load below 80% of
the unit’s rated capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately
upon receipt. However, after receiving a
new UPS, to ensure the battery’s maximum
charge capacity, it is recommended that
you charge the battery for at least 8 hours.
Your UPS is e quipped with an auto charge
feature. When the UPS is plugged into an
AC outlet, the battery will automatically
charge whether the UPS is turned on or
turned o.
Note: This UPS is designed with a safety
feature to keep the system from being turned
on during shipment. The rst time you turn
the UPS on, you will need to have it connect-
ed to AC power or it will not power up.
2. With the UPS unit turned oand unplugged,
connect your computer, monitor, and any
other peripherals requiring battery backup
into the battery power supplied outlets. Plug
the other peripheral equipment (eg. printer,
scanner, speakers, etc.) into the full time
surge protection outlets.
DO NOT plug a laser printer, paper shredder,
copier, space heater, vacuum cleaner, sump
pump or other large electrical device into
the Battery and Surge Protected Outlets.
The power demands of these devices will
overload and possibly damage the unit.
3. Plug the UPS into a 2 pole, 3 wire grounded
receptacle (wall outlet). Make sure the wall
branch outlet is protected by a fuse
or circuit breaker and does not service
equipment with large electrical demands
(e.g. air conditioner, refrigerator, copier,
etc.). The warranty prohibits the use of
– continued


Specyfikacje produktu

Marka: CyberPower
Kategoria: UPS
Model: CP1500AVRLCDTAA

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z CyberPower CP1500AVRLCDTAA, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje UPS CyberPower

CyberPower

CyberPower SM180KMFX Instrukcja

9 Października 2024
CyberPower

CyberPower RT33030KE Instrukcja

9 Października 2024
CyberPower

CyberPower SM300KMFX Instrukcja

9 Października 2024
CyberPower

CyberPower OLS3S20KEXL Instrukcja

9 Października 2024
CyberPower

CyberPower UT1050EI Instrukcja

9 Października 2024
CyberPower

CyberPower BU600E Instrukcja

9 Października 2024
CyberPower

CyberPower VP700ELCD Instrukcja

9 Października 2024
CyberPower

CyberPower VP1000ELCD Instrukcja

9 Października 2024

Instrukcje UPS

Najnowsze instrukcje dla UPS

APC

APC Back-UPS BN575G Instrukcja

12 Października 2024
APC

APC Smart-UPS SMC1000-2UC Instrukcja

12 Października 2024
APC

APC Back-UPS BX550CI-AR Instrukcja

12 Października 2024
APC

APC Back-UPS BN600G Instrukcja

12 Października 2024
APC

APC Back-UPS BX650CI-GR Instrukcja

12 Października 2024
APC

APC Back-UPS BX950U-FR Instrukcja

12 Października 2024
APC

APC Back-UPS BX650LI Instrukcja

12 Października 2024
APC

APC Easy UPS BVX1000UXI Instrukcja

12 Października 2024
Eaton

Eaton EX 3000VA 3U XL Instrukcja

11 Października 2024