Strona 1/32
Crestron Green Light™
DIN-2MC2
DIN Rail Motor Control
Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at:
Crestron Electronics, Inc.
15 Volvo Drive
Rockleigh, NJ 07647
1-888-CRESTRON
Regulatory Compliance
This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions:
(1) This device may not cause harmful interference and (2) this device must accept any interference received,
including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Industry Canada (IC) Compliance Statement
As of the date of manufacture, the DIN-2MC2 has been tested and found to comply with specifications for CE
marking and standards per EMC and Radiocommunications Compliance Labelling.
All brand names, product names and trademarks are the property of their respective owners.
©2010 Crestron Electronics, Inc.
Crestron DIN-2MC2 DIN Rail Motor Control
Contents
DIN Rail Motor Control: DIN-2MC2 1
Introduction ...............................................................................................................................1
Features and Functions................................................................................................1
Applications.................................................................................................................3
Specifications ..............................................................................................................4
Physical Description....................................................................................................5
Setup .......................................................................................................................................... 9
Network Wiring...........................................................................................................9
Identity Code ............................................................................................................... 9
Installation ................................................................................................................. 10
Hardware Hookup .....................................................................................................12
Programming Software............................................................................................................ 14
Earliest Version Software Requirements for the PC ................................................. 14
Programming with Crestron SystemBuilder.............................................................. 14
Programming with D3 Pro.........................................................................................15
Programming with SIMPL Windows ........................................................................ 15
Example Program...................................................................................................... 17
Uploading and Upgrading........................................................................................................18
Establishing Communication.....................................................................................18
Programs and Firmware ............................................................................................19
Program Checks ........................................................................................................ 19
Operation .................................................................................................................................20
Problem Solving ...................................................................................................................... 22
Troubleshooting......................................................................................................... 22
Check Network Wiring..............................................................................................23
Reference Documents................................................................................................ 25
Further Inquiries ........................................................................................................25
Future Updates ..........................................................................................................25
Return and Warranty Policies .................................................................................................. 26
Merchandise Returns / Repair Service ...................................................................... 26
CRESTRON Limited Warranty.................................................................................26
Operations & Installation Guide – DOC. 6665B Contents
i


Specyfikacje produktu

Marka: Crestron
Kategoria: sterownik
Model: DIN-2MC2
Częstotliwość wejściowa AC: 50 - 60 Hz
Napięcie wejściowe AC: 120 - 240 V
Wysokość produktu: 94.2 mm
Szerokość produktu: 106 mm
Głębokość produktu: 59.5 mm
Waga produktu: 210 g
Certyfikaty: CE
Zakres temperatur (eksploatacja): 0 - 40 °C
Zakres wilgotności względnej: 10 - 90 %
Diody LED: NET, NET ID, Open & close, Override, Power, Reset, Setup
Model: Dwukierunkowy kontroler silnika
Zasilanie: 3 W
Emisja ciepła: 10 BTU/h
Opcje instalacji: Montaż na szynie DIN
AWG przekrój przewodu (max): 12
Blok zacisków NET: 2x 4-pin 3.5mm
Kanały sterowania silnikiem: 2 kan.
Maksymalna moc silnika: 1 hp
Blok zacisków przekaźnika: 1x 8-pin 3.5mm
Blok zacisków zasilania/przesterowania: 2x 2-pin 3.5mm

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Crestron DIN-2MC2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje sterownik Crestron

Instrukcje sterownik

Najnowsze instrukcje dla sterownik

HQ Power

HQ Power HQDB10002 Instrukcja

2 Października 2024
AirTurn

AirTurn BT500 Instrukcja

21 Września 2024
Chauvet

Chauvet FC-W Instrukcja

16 Września 2024
Chauvet

Chauvet ShowXpress Instrukcja

16 Września 2024
Chauvet

Chauvet RFC-XL Instrukcja

16 Września 2024
Chauvet

Chauvet DMX-RT4 Instrukcja

16 Września 2024
Chauvet

Chauvet FC-T Instrukcja

16 Września 2024
Korg

Korg microKEY2-37 Instrukcja

16 Września 2024
Korg

Korg microKEY2-49 Instrukcja

16 Września 2024