Instrukcja obsługi Creda TPRIII100E

Creda grzejnik TPRIII100E

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Creda TPRIII100E (27 stron) w kategorii grzejnik. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/27
INSTRUCTION MANUAL
Installation and Operating
These instructions should be read carefully and
retained for future use. Note also the information
presented on the appliance.
Creda TPRIIIE Panel Heater
Models: TPRIII050E / TPRIII075E / TPRIII100E / TPRIII125E
TPRIII150E / TPRIII200E / TPRIII300E
08/53455/0 ISSUE 1
ELECTRICAL INSTALLATION
WARNING - The electrical installation of this heater must be carried out by a suitably qualied
or trained electrician, and be in strict accordance with the current wiring Regulations BS
7671. The supply must be connected via a switched fused spur with a fuse rated suitably
for the appliances ex. Failure to follow these instructions will mean that the manufacturer’s
instructions have not been adhered to. . THERE ARE NO EXCEPTIONS
WARNING - Minimum clearances and IP zone requirements must be adhered to in accordance
with the current wiring regulations. The wires in this mains lead are coloured in accordance with
the following code:
GREEN AND YELLOW: EARTH
BLUE: NEUTRAL
BROWN: LIVE
This heater must be earthed
Not suitable for connection via a plug top
Do not locate the heater immediately below a xed electrical point i.e. socket outlet.
The heater is tted with a length of exible cable type H05VV-F size 3 x 1.0mm² for 500W to 2kW and
3 x 1.5mm² on 3.0kW models for connection to the xed wiring of the premises through a suitable
connection box positioned adjacent to the heater. A means for disconnection must be incorporated
in the xed wiring of the premises in accordance with the current wiring regulations. The supply
circuit to the heater must incorporate a double pole isolating switch having a contact separation of
at least 3mm. Products that are supplied without a plug are for installation into the xed wiring of the
property, via a suitable double pole switched fused spur with a fuse rated suitably for the appliances
ex. Typical fuse ratings for 230V equipment - Up to 700W = 3A, over 700W = 13A.
In installation the supply cord may be cut to the appropriate length for the electrical connection
point. Excess cable should not be inserted and stored behind the heater.
WARNING: This heater must not be connected to the electricity supply via an external switching
device (such as a timer) or a circuit that is regularly switched on and o by the utility supplier.
Failure to follow this warning could result in the heater’s thermal cut-o being inadvertently
reset and could create a re hazard. Cables/exes that are supplied pre-tted to the product
must NOT be extended.
CHILD SAFETY
WARNING - This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of appliance by a person responsible for their safety.
This appliance can be used by children from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without supervision.
Children of less than 3 years should be kept away unless continuously supervised.
Children aged from 3 years and less than 8 years shall only switch on/o the appliance provided
that it has been placed or installed in its intended normal operating position and they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children aged from 3 years and less than 8 years shall not regulate
and clean the appliance or perform user maintenance. This product contains a replaceable
battery. WARNING - KEEP BATTERIES OUT OF REACH OF CHILDREN.
WARNING - Packaging should be disposed o responsibly as the EPS used could be a
potential choking harzard for children.
3
Model Identier(s):
TPRIII
050E
TPRIII
075E
TPRIII
100E
TPRIII
125E
TPRIII
150E
TPRIII
200E
TPRIII
300E
Nominal heat
output Pnom 1 kW0.5 kW 0.75 kW 1.25 kW 1.5 kW 2 kW 3 kW
Height (mm)
430 430 430 430 430 430 430
Width (mm)
450 620 620 690 690 860 860
Depth (mm)
108 108 108 108 108 108 143
Minimum heat
output (indicative) Pmin N.A. N.A. N.A. N.A. N.A. N.A. N.A.
Maximum continuous
heat output Pmax,c 10.5 0.75 1.25 1.5 2 3
Auxiliary electricity Consumption
At nominal heat output elmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00
At minimum heat output elmin 0.00 0.00 0.00 0.00 0.00 0.00 0.00
In standby mode elSB <0.0005 <0.0005 <0.0005 <0.0005 <0.0005 <0.0005 <0.0005
With open window detection Yes
With adaptive start control Yes
Type of heat output/ room temperature control
With electronic room temperature control Yes
Electronic room temperature control plus week timer Yes
With open window detection Yes
With adaptive start control Yes
This product complies with Lot20 of the Energy Eciency Directive (2015/1188).
Energy Related Product Directive
Technical Details
4


Specyfikacje produktu

Marka: Creda
Kategoria: grzejnik
Model: TPRIII100E

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Creda TPRIII100E, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje grzejnik Creda

Creda

Creda TSR12AW Instrukcja

15 Września 2024
Creda

Creda CECOT6 Instrukcja

15 Września 2024
Creda

Creda CECOT4 Instrukcja

15 Września 2024
Creda

Creda CECOT1 Instrukcja

15 Września 2024
Creda

Creda CECOT3 Instrukcja

15 Września 2024
Creda

Creda TSR18MW Instrukcja

15 Września 2024
Creda

Creda TSR12ACW Instrukcja

15 Września 2024
Creda

Creda TPRIII150E Instrukcja

15 Września 2024
Creda

Creda TSR18ACW Instrukcja

15 Września 2024
Creda

Creda CAR150 Instrukcja

15 Września 2024

Instrukcje grzejnik

Najnowsze instrukcje dla grzejnik