Installation and Operating Instructions
CUF2TS & CUF3TS
The product complies with the European Safety Standards EN60335:2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014:1,
EN55014:2, EN61000:3-2 and EN61000:3-3 which cover the essential requirements of EMC Directive 2014/30/EU and the LVD Directive 2014/35/EU.
08/52965/0 Issue 7
As with all portable heang appliances: This product is suitable only for well insulated spaces or occasional use.
Fan Heaters
Model(s) : CUF2TS & CUF3TS
Dimensions
(millimetres)
IMPORTANT SAFETY ADVICE
READ THESE INSTRUCTIONS BEFORE USE.
DO NOT use the heater on deep pile carpets or
the long hair type of rugs, or less than 750mm
(30”) away from any overhanging surface. Keep
combustible materials such as drapes and other
furnishings clear from the front, sides and rear
of the heater. Do not use the heater to dry your
laundry.
DO NOT use the heater in the immediate
surroundings of a bath, a shower or a swimming
pool.
DO NOT place the heater directly below a xed
socket outlet.
The socket outlet must be accessible at all times
to enable the mains plug to be disconnected as
quickly as possible.
DO NOT COVER or obstruct the air inlet and
outlet openings in any way.
The heater must be on a at stable surface when
in use.
DO NOT operate the heater with the mains lead
overhanging the front outlet grille.
The heater carries the warning symbol
indicating that it must not be covered.
WARNING: In order to avoid overheating do not
cover the heater.
The instruction leaet belongs to the appliance
and must be kept in a safe place. If changing
owners, the leaet must be surrendered to the
new owner.
WARNING: To avoid danger of suffocation please
remove all packaging materials particularly plastic
and EPS and keep these away from vulnerable
people,children and babies.
WARNING: To avoid the risk of accidental
strangulation from the supply cord all children and
vulnerable people must be supervised when in the
vicinity of the product whether it is working or not.
IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
IMPORTANT: If the mains lead of this appliance is
damaged, it must be replaced by the manufacturer
or its service agent or a similarly qualied person
in order to avoid a hazard.
WARNING: In order to avoid a hazard due to
inadvertent resetting of the thermal cut-out,
this appliance must not be supplied through an
external switching device, such as a timer, or
connected to a circuit that is regularly switched
on and off by the utility.
This appliance can be used by children aged from
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience or knowledge if they have been given
supervision or instruction concerning the use of
the appliance in a safe way and understand the
hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall
not be made by children without supervision.
Children of less than 3 years should be kept away
unless continuously supervised.
Children aged from 3 years and less than 8 years
shall only switch on/off the appliance provided
that it has been placed or installed in its intended
normal operating position and they have been
given supervision or instruction concerning the
use of the appliance in a safe way and understand
the hazards involved. Children aged from 3
years and less than 8 years shall not plug in,
regulate and clean the appliance or perform user
maintenance.
CAUTION: Some parts of this product can
become very hot and cause burns. Particular
attention has to be given where children and
vulnerable people are present.
Avoid use of an extension cord because the
extension cord may overheat and cause risk of
re.
Model(s) Specication
CUF2TS 2.0kW Thermostat & Switch
CUF3TS 3.0kW Thermostat & Switch
H W D
243 230 163
(See Fig. 3)
(See Fig. 2)
Switch knob
Power indicator
light
Thermostat knob
Air outlet
Fig. 1
Electrical connection
This heater must be used on an supply only and the voltage A.C. ~
marked on the heater must correspond to the supply voltage. This
heater is tted with a plug incorporating a 13 amp fuse. When
replacing the fuse, a 13 amp fuse approved by ASTA to BS 1362
must be used.
If the plug is not suitable for the socket outlets in your home, the
plug must be cut off and an appropriate one tted. A plug cut off
from a mains lead will give a shock hazard if inserted into a 13
amp socket elsewhere in the house. To avoid this, it should be
disposed of immediately.
NOTE: The fuse cover of a non-rewirable plug must be retted
when changing the fuse. Should the cover become lost, the plug
must not be used until the correct replacement fuse cover is
obtained from your supplier or by contacting our customer helpline.
IMPORTANT: The wires in this mains lead are coloured in
accordance with the following code:
BLUE: NEUTRAL
BROWN: LIVE
As the colours of the wires in the mains lead may not correspond
with the coloured markings in your plug, proceed as follows:
Connect the wire to the terminal marked ‘ or coloured BROWN L
RED BLUE. Connect the wire to the terminal marked N or
coloured .BLACK Note: L or must not be connected to the N
EARTH E terminal marked or or coloured or GREEN GREEN
AND YELLOW.
If in doubt, consult your electrician.
Using the Heater
Main Elements - See Fig 1.
1. Power Indicator Light
2. Thermostat Control Knob
3. Switch Knob
4. Air Outlet
Heat Control - see Fig. 2
Fig. 2
Thermostat Control - see Fig. 3
The heat output is controlled by the
thermostat, according to the room
temperature.
Turn the thermostat knob fully clockwise to
maximum setting initially. When the room
is warm enough, reduce the setting slowly
until the heater just clicks off.
- Off
- Cool Blow*
- Half Heat
- Full Heat
Fig. 3
The heater will now cycle on and off to maintain your selected room
temperature. An audible click may be heard when the thermostat
operates - this is normal.
Note: If the heater does not come on when the thermostat is at a
low setting, this is normally because the room is warmer than the
thermostat setting and is not a fault.
* When the heat control is set to for cool blow, set the thermostat
control to maximum.
Position will turn the heater on and off to maintain a temperature
of approximately 5°C.
Safety - overheat protection
For your safety, this appliance is tted with a thermal cut-out. In the
event that the product overheats, the cut-out switches the heater
off automatically. To bring the heater back into operation, remove
the cause of overheating, then turn off the electrical supply to the
heater for a few minutes.
When the heater has cooled sufciently reconnect and switch on
the heater.
If the cut-out operates repeatedly, contact your supplier.
Cleaning
WARNING ALWAYS DISCONNECT FROM THE POWER
SUPPLY BEFORE CLEANING THE HEATER.
Do not use detergents, abrasive cleaning powders or polish of
any kind on the heater.
Wipe with a dry cloth to remove dust and a damp cloth (not wet)
to clean off stains. Be careful not to allow moisture into the heater.
Ensure that dust or uff does not accumulate inside the heater
as this could lead to overheating of the element. Use a vacuum
cleaner to remove any uff which does accumulate.
Recycling
For electrical products sold within the European
Community.
At the end of the electrical products useful life it
should not be disposed of with household waste.
Please recycle where facilities exist. Check with
your Local Authority or retailer for recycling advice
in your country.
ModelIdentier(s): CUF2TS CUF3TS
Heat output
Nominal heat output Pnom 2.0 3.0 kW
Minimum heat output (indicative) Pmin 0.8 1.5 kW
Maximum continuous heat output Pmax,c 2.0 3.0 kW
Auxiliary electricity Consumption
At nominal heat output 0.0 0.0elmax kW
At minimum heat output elmin 0.0 0.0 kW
In standby mode elSB 0.0 0.0 kW
Type of heat output/ room temperature control
Mechanical thermostat room temperature control Yes
Contact details
GDC Group Limited
Millbrook House, Grange Drive,
Hedge End, Southampton.
SO30 2DF
Telephone: 0844 879 3588
Email: customer.services@gdcgroup.co.uk
Visit: www.gdcgroup.co.uk


Specyfikacje produktu

Marka: Creda
Kategoria: grzejnik
Model: CUF2TS

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Creda CUF2TS, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje grzejnik Creda

Creda

Creda TSR12AW Instrukcja

15 Września 2024
Creda

Creda CECOT6 Instrukcja

15 Września 2024
Creda

Creda CECOT4 Instrukcja

15 Września 2024
Creda

Creda CECOT1 Instrukcja

15 Września 2024
Creda

Creda CECOT3 Instrukcja

15 Września 2024
Creda

Creda TSR18MW Instrukcja

15 Września 2024
Creda

Creda TSR12ACW Instrukcja

15 Września 2024
Creda

Creda TPRIII150E Instrukcja

15 Września 2024
Creda

Creda TSR18ACW Instrukcja

15 Września 2024
Creda

Creda CAR150 Instrukcja

15 Września 2024

Instrukcje grzejnik

Najnowsze instrukcje dla grzejnik