PRODUCT & INSTALLATION SPECIFICATIONS
PRODUCT & INSTALLATION SPECIFICATIONS
PRODUCT & INSTALLATION SPECIFICATIONS
PRODUCT & INSTALLATION SPECIFICATIONSPRODUCT & INSTALLATION SPECIFICATIONS
Electrical
Requirements
120 VAC
25" 20 1/2" 25 1/2"23" 28" 40,000 40,000 Qty 1
31" 23" 34"20 1/2" 25 1/2" 60,000 60,000 Qty 1
32 1/2" 20 1/2" 35 1/2" 25 1/2"23" 80,000 80,000 Qty 1
39 1/2" 20 1/2" 42 1/2" 25 1/2"23" 100,000 100,000 Qty 1
32 1/2" 20 1/2" 35 1/2" 25 1/2"23" 90,000 90,000 Qty 1
27" 20 1/2" 25 1/2"23" 30" 70,000 70,000 Qty 1
32 1/2" 20 1/2" 35 1/2" 25 1/2"23" 90,000 90,000 Qty 1
39 1/2" 20 1/2" 42 1/2" 25 1/2"23" 110,000 110,000 Qty 1
47 3/4" 20 1/2" 25 1/4" 25 1/2"50" 40,000 40,000 Qty 1
32 1/2" 20 1/2" 25 1/4" 35 1/2" 25 1/2" Qty 1
22 1/2" 22 1/2" 22 1/4" 22 1/4"34" None
16" 15" 11 3/8" 16 1/4"18 1/8" Qty 1
120 VAC
10 1/8" 11 3/8" 17"13 5/8" 13" 15,000 15,000 None
11 7/8" 20 1/4" 13 1/8" 23 1/4"13" 30,000 30,000 None
21" 21" 13" 24" 24 1/4" 60,000 60,000 None
28 1/4" 22 1/8" 11" 30 1/8" 23"
34 1/4" 22 1/8" 11" 36 1/8" 23"
30 3/4" 32 3/8" 23"22 1/8" 11"
35 3/4" 23"22 1/8" 11" 37 5/8"
42 1/4" 44 1/8"22 1/8" 11" 23"
13 3/4" 16" 16 3/4"11" 15 1/4"
15 1/2" 22 1/4" 11" 17" 23"
22 1/8" 21 7/8" 11" 22 3/4"24 7/8"
20 3/4" 1" 24" 24 1/4" 3"
26 1/2" 1" 24" 30" 3"
31 3/4" 3"1" 35 1/2"24"
34 1/2" 1" 24" 38" 3"
14 1/2" 1" 22" 16" 3"
20 1/2" 1" 22"16" 3"
17 1/2" 1" 26" 19" 3"
24 1/2" 1" 19" 26" 3"
14 1/2" 17 1/2" 22" 16 1/4" 18"
16 3/4" 26"17 1/4" 18 1/2" 18"
31 1/2" 20 1/2" 32 1/2" 21 1/4"15"
26 1/2" 23" 24" 24"30"
24" 18" 26 1/4" 26 3/4" 19"
11 3/8" 26 1/4"18" 14 3/8" 18 7/8"
14 1/4" 17 1/2" 22" 15 1/2" 18"
13 1/2" 8" 10" 15" 9"
7 1/2" 17 1/8" 26 1/4" 8 3/4" 18"
28 1/4" 23 1/2" 29 1/2"10 3/4" 26 3/4"
43 3/8" 17 1/8" 24 1/8" 45 1/4" 18 3/8"
26 1/2" 20 1/8" 21 1/8"24" 30"
43 3/8" 17 1/2" 24 1/8" 45 1/4" 18"
40 5/8" 20 3/4"25 1/4" 42 1/8" 26 1/2"
20 3/4" 23" 33 3/4" 20 1/2" 22 3/4"
23 3/4" 33"22 3/4" 23 1/2" 22 1/2"
20 3/4" 1" 22 3/4" 1"35"
23 3/4" 1" 1"34 1/4" 25 3/4"
23 1/4" 17 1/4" 24 1/2"15" 18"
23 3/4" 24 3/4" 20 1/2" 25 1/2"26 3/4"
14 3/4" 17 1/8" 13" 15 3/4" 17 3/4"
29 1/4" 22 3/4" 10 3/4" 30 1/4" 29"
C2C42 42" Grill w/ Hood Lights 10 1/4"
Model Product Description Cutout Dimensions Overall Dimensions Total BTU Ratings
Grills Height Width Depth Height Width Depth NGLP
C1C28 28" Grill w/ Hood Lights 10 1/4"
C2C34 34" Grill w/ Hood Lights 10 1/4"
C2C36 36" Grill w/ Hood Lights 10 1/4"
C1S36 36" Grill w/ Hood Lights 10 1/4"
C2SL36 36" Grill w/ Hood & LED Lights 10 1/4"
C2SL42 42" Grill w/ Hood & LED Lights 10 1/4"
C2SL30 30" Grill w/ Hood & LED Lights 10 1/4"
C1HY50 50" Hybrid Grill w/ Hood Lights 12 1/2"
C1CH36 36" Charcoal Grill 12 1/2" N/A
C1CHCS Asado Smoker N/A17"
C1EL120SM 120V 1300W 11AElectric Grill Manual Control 3 3/8"
Side Burners Height Width Depth Height Widthh Depth NGLP
C1SB Coyote Single Side Burner 10 1/4"
C1DB Coyote Dual Side Burner 10 1/4"
C1PB Coyote Power Burner 10 1/4"
Insulated Jackets Height Width Depth Height Widthh Depth Notes
CJAKTCC2 Insulated Jacket for 28" Grills For Combustible Construction11"
CJAKTCC3 Insulated Jacket for 34" Grills For Combustible Construction11"
CJAKTCS36 Insulated Jacket for 36" Grills For Combustible Construction11"
CJAKTCS42 Insulated Jacket for 42" Grills For Combustible Construction11"
Access Doors Height Widthh Depth Height Widthh Depth Notes
CJAKTC1SB Insulated Jacket for C1SB 11" For Combustible Construction
CJAKTC1DB Insulated Jacket for C1DB 11" For Combustible Construction
CJAKTC1PB Insulated Jacket for C1PB 11" For Combustible Construction
CDA2426 20 1/2"26" Double Access Door N/A
CDA2431 N/A31" Double Access Door 20 1/2"
CDA2439 N/A39" Double Access Door 20 1/2"
CDA2436 N/A36" Double Access Door 20 1/2"
CSA2014 Single Access Door 20" x 14" N/A20 1/2"
CSA1420 Single Access Door 14" x 20" N/A14 1/2"
CSA2417 N/ASingle Access Door 24" x 17" 24 1/2"
CSA1724 N/ASingle Access Door 17" x 24" 17 1/2"
Drawers Height Width Depth Height Widthh Depth Notes
C2DC 2 Drawer Cabinet 20 1/2" N/A
C3DC 3 Drawer Cabinet 24 1/2" N/A
CSSD N/ASingle Storage Drawer 13 1/2"
CDPC31 31" Dry Pantry 20 1/2" N/A
CTC Dual Pull Out Trash & Recycle 24" N/A
CSTC N/ASingle Pull Out Trash & Recycle 23 7/8"
CPOD LP Tank or Trash Drawer 20 1/2" N/A
CPTH Paper Towel Holder 8 1/4" N/A
CWD Warming Drawer 9 1/2" N/A
Combo Drawers Height Width Depth Height Widthh Depth Notes
CSPRK N/ASpice Rack 25"
CCD-2DC Double Drawer Combo 20 1/4" N/A
CCD-2DC31 31" Double Drawer Combo 20 1/2" N/A
CCD-POD Pull Out Drawer Combo 20 3/8" N/A
C1SINK1618 Sink - Universal Mount Includes drain but no faucet13"
CRC Refreshment Center 10" Drain Hose Included
C1BIR24 5.5 Outdoor Refrigerator Qty 1 Plug Needed - Vented Bottom Front33 1/4"
CDIC Drop In Cooler 12" Can be turned in either direction
CPOC Pull Out Ice Chest 17 1/2" N/A
CBIR21TK CBIR Refrigerator Trim Kit 34" N/A
C1BIR24TK C1BIR24 Refrigerator Trim Kit 33 1/4" N/A
CJAKTCS30 Insulated Jacket for 30" Grills For Combustible Construction11"
CCD-WD Warming Drawer Combo 19 1/2" Qty 1 Plug Needed - unit is 450 Watt
Refrigeration & Refreshment Centers Height Width Depth Height Widthh Depth Notes
CBIR 4.1 Outdoor Refrigerator Qty 1 Plug Needed - Vented Bottom Front34"
www.coyoteoutdoor.com
PRODUCT & INSTALLATION SPECIFICATIONS
PRODUCT & INSTALLATION SPECIFICATIONS
PRODUCT & INSTALLATION SPECIFICATIONS
PRODUCT & INSTALLATION SPECIFICATIONSPRODUCT & INSTALLATION SPECIFICATIONS
OPENING
HEIGHT
DOORS / DRAWERS
OPENING WIDTH
OPENING
DEPTH
OPENING
HEIGHT
GRILL
OPENING
GRILL
OVERHANG
TOP VIEW
OPENING WIDTH
2 1/ "2
OPENING
HEIGHT
DOORS / DRAWERS
OPENING WIDTH
OPENING
DEPTH
OPENING
HEIGHT
24"
LINER
OPENING
7/ "8
JACKET
OVERHANG
TOP VIEW
OPENING WIDTH
24"
NON-COMBUSTIBLE
NON-COMBUSTIBLE
NON-COMBUSTIBLE
NON-COMBUSTIBLENON-COMBUSTIBLE
CONSTRUCTION
CONSTRUCTION
CONSTRUCTION
CONSTRUCTIONCONSTRUCTION
Insulated Jacket
Insulated Jacket
Insulated Jacket
Insulated JacketInsulated Jacket NOT Required
NOT Required
NOT Required
NOT RequiredNOT Required
FRONT VIEW FRONT VIEW
1 1/ "2 MIN
INCLUDING
COUNTERTOP
Combustible material can not be within 24" of the grills frame
This applies to all directions - horizontal & vertical
Shaded area above on "TOP VIEW" illustrates the 24" minimum
requirement (not to scale for rendering purposes)
The grill is designed to hang from the counter top with no support
underneath
Minimum rear clearance for the hood to open is 2"
If you have a wall/partition behind the grill, the minimum rear clearance
to that wall should be at least 7" to allow for ventilation of the exhaust
24"
If using combustible material within 24" of the grill frame, you MUST use
the corresponding Coyote Insulated Jacket
Using a insulated jacket, does not waive any other standard installation
procedure (ventilation, connections, etc)
The jacket is designed to hang from the counter top with no support
underneath
Minimum clearance for hood to open is 2"
If you have a wall/partition behind the grill, the minimum rear clearance
to that wall should be at least 7" to allow for ventilation of the exhaust
Ventilation Requirements:
Ventilation Requirements:
Ventilation Requirements:
Ventilation Requirements:Ventilation Requirements:
Regardless if you are using a combustible or non-combustible building material, you must include at least two vents within the island.
These vents must be at least 20 sq. in. each and allow fresh air to move from the grill cabinet to the exterior environment.
For a propane setup, the vents should be installed lower as propane is heavier than air.
For a natural gas setup, the vents should be located higher in the island, as natural gas is lighter than air.
Do not locate the two vents on the same wall of the island. Cross ventilation is key to allow any excess heat or trapped gas to dissipate.
11/ "2
15
/ "8
11
/ "2
1 1/ "2 MIN
COMBUSTIBLE
COMBUSTIBLE
COMBUSTIBLE
COMBUSTIBLECOMBUSTIBLE CONSTRUCTION
CONSTRUCTION
CONSTRUCTION
CONSTRUCTION CONSTRUCTION
Insulated Jacket
Insulated Jacket
Insulated Jacket
Insulated JacketInsulated Jacket Required
Required
Required
RequiredRequired
7/ "8
INCLUDING
COUNTERTOP
1
3/ "4
2 1/ "2
21/ "2
2"
G
GAS
CONNECTION
G
4 1/ "8
4 1/ "8G
GAS
CONNECTION
4 1/ "8
G
2 3/ "4
Important Note to Installer. This file is not intended to replace your Owners' Manual which contains specific safety requirements and
consumer guidelines. Please refer to your Owners' Manual prior to installing or operating your builtin grill.


Specyfikacje produktu

Marka: Coyote
Kategoria: nieskategoryzowany
Model: Insulated Jacket CJAKTCS36

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Coyote Insulated Jacket CJAKTCS36, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Coyote

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024