Instrukcja obsługi Climachill PAC12J


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Climachill PAC12J (13 stron) w kategorii klimatyzacja. Ta instrukcja była pomocna dla 8 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/13
1/13
USER MANUAL
Portable Air Conditioner and Heater
With Heat Pump Technology
PAC12J
12,000btu Cool & Heat Portable Air Conditioner
Please read this manual carefully prior to operating the product.
Please keep ALL packaging for duration of Warranty Period
2
/
13
TABLE OF CONTENTS
IMPORTANT SAFEGUARDS 2
INTRODUCTION / WARRANTY 4
PRODUCT DIAGRAM 5-7
INSTALLATION 8-9
OPERATION 10
WATER DRAINAGE 9
MAINTENANCE 12
TROUBLESHOOTING 13
TECHNICAL SUPPORT / CUSTOMER SERVICE CONTACT 13
IMPORTANT SAFEGUARDS
Before installing and using your portable air conditioner and heater, it is important that you read this owners
manual carefully. Store this manual in a safe place for future reference.
This instruction manual is used for guidance and does not form part of a contract. It reserves the right to make
technical changes without prior notice.
1. Always place the unit on a level surface.
2. The appliance shall be installed in accordance with national wiring regulation.
3. The unit must be connected to a correctly grounded power supply. For your safety, this unit is
grounded through the power cord plug when connected to a grounded wall outlet. Do not use an
adapter plug or extension cord.
4. Do not install the unit in an area where gas leakage may occur and/or in an explosive atmosphere.
5. Do not apply an insecticide or any type of flammable spray on the unit.
6. Confirm drainage piping is connected properly.
7. Do not start or stop the unit by inserting or pulling out the power plug.
8. Do not operate with wet hands.
9. Close supervision is necessary when the unit is used near children. The unit in not intended for use by
children.
10. Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills.
11. Do not expose skin or eyes directly to cool air for a long period of time.
12. If an abnormal odour or smoke comes out of the unit, disconnect the unit immediately and contact a
qualified service technician.
13. When opening the filter cover, do not touch the metal parts in the unit’s interior.
14. Do not immerse the unit in water or any type of liquid. Do not use the unit in the immediate
surroundings of a bath, shower, or swimming pool, or in any other steamy, wet areas.
15. When cleaning the unit, always turn the unit off and unplug the power cord.
16. Always inspect the power cord for signs of damage before use. If the power cord is damaged, it must
be replaced by the manufacturer or a qualified service technician.
17. Do not place a plant or allow a pet in the direct path of the airflow to avoid injury.
18. Do not put a stove, etc, where it would be exposed to the direct airflow. It may affect combustion.
19. Do not sit on the unit or place anything on it.
20. Before storing, the water must be drained from the unit and the filters cleaned.
21.
The appliance must be placed in an area without any continuously sources of ignition (for example: open
flames , gas or electrical appliances in operation).
22.
Do not puncture and do not burn.
23.
This appliance contains Y g (see rating label back of unit ) of R290 refrigerant gas.
24.
R290 is a refrigerant gas that complies with the European directives on the environment. Do not puncture
any part of the refrigerant circuit.
25.
If the appliance is installed, operated or stored in a nonventilated area, the room must be designed to
prevent to the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of
3
/
13
the refrigerant caused by electric heaters, stoves, or other sources of ignition.
26.
The appliance must be stored in such a way as to prevent mechanical failure.
27. Contact authorized service technician for repair or maintenance of this unit.
28. Unplug the unit if strange sounds, smell, or smoke comes from it.
General Information
Recycling
This marking indicates that this product should not be disposed with other household wastes throughout the EU.
To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return your used device, please use the
return and collection systems or contact the retailer where the product was purchased. They can take this product
for environmental safe recycling.
Warning
The unit creates water which is collected in an internal water tank which has a rubber drain plug, it is very
unlikely but if this tank becomes damaged during transport or the rubber bung comes out then it is possible
that the unit will leak water when it is operated. Prior to use make sure the drain plug is in place & then
during first use periodically check the unit to make sure it isn’t leaking water (look at bottom / under the unit)
during first use do not turn the unit on and leave it unattended for a long period of time without checking.


Specyfikacje produktu

Marka: Climachill
Kategoria: klimatyzacja
Model: PAC12J

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Climachill PAC12J, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje klimatyzacja Climachill

Climachill

Climachill KYD44 Instrukcja

28 Września 2024
Climachill

Climachill KYD32 Instrukcja

28 Września 2024
Climachill

Climachill PAC12K Instrukcja

28 Września 2024
Climachill

Climachill PAC15 Instrukcja

28 Września 2024
Climachill

Climachill PAC18J Instrukcja

28 Września 2024
Climachill

Climachill PAC12H Instrukcja

28 Września 2024
Climachill

Climachill PAC15K Instrukcja

28 Września 2024
Climachill

Climachill PAC12J Instrukcja

28 Września 2024
Climachill

Climachill PAC12L Instrukcja

28 Września 2024
Climachill

Climachill PAC18L Instrukcja

28 Września 2024

Instrukcje klimatyzacja

Najnowsze instrukcje dla klimatyzacja