Instrukcja obsługi Clas Ohlson UNI-T UT133B

Clas Ohlson multimetr UNI-T UT133B

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Clas Ohlson UNI-T UT133B (64 stron) w kategorii multimetr. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/64
Eng lishSve nsk aNo r skSuo miDeu ts ch
UNI-T UT133B
Multimeter
Multimeter UNI-T UT133B
UNI-T UT133B multimeter
Yleismittari UNI-T UT133B
Art.no. Model
36-7745 UT133B Ver. 20190705
3
Eng lis h
UNI-T Multimeter
Art.no 36-7745 Model UT133B
Please read theentire instruction manual before using theproduct and then save
it for future reference. We reserve theright for any errors in text or images and any
necessary changes made to technicaldata. In theevent of technical problems
or other queries, please contact our Customer Services (see address details on
theback).
Information about this measuring instrument
This multimeter has been constructed and tested in accordance with therequirements
of Measurement Category III (CAT III) up to 600 V nominal voltage and Pollution
Degree2.
Categorisation
Measuring instruments are classified into categories according to what kind of
electrical environment they can be used in and how safe/protective they are at
withstanding overvoltages.
The Measurement Category of theinstrument will be marked on theratingplate.
The Measurement Category indicates how capable theinstrument is of withstanding
overvoltages which could be dangerous for theuser.
In brief, thecategorisation can be described like this:
In theevent of asudden overvoltage on thepower grid (atransient energy spike
from alightning strike for example) thedanger is greatest at thepoint where
thepower supply service cable enters abuilding.
Further in thebuilding, theresistance (impedance) in themains supply
cables increases and connected appliances and devices reduce and divide
theovervoltage. Therefore, theMeasurement Category (also called Overvoltage
Installation Category) of themeasuring instrument indicates which electrical
environment theinstrument is designed to be usedin.
The categories that measuring instruments are classified into are:
CAT : For measuring electronics and products that have abuilt-in protection I
from overvoltage.
CAT : For measuring single-phase equipment connected to ahousehold mains II
supply, both through wall sockets and fixed installation.
CAT : For measuring electrical wiring installed in buildings. Examples are III
measurements on fixed installation cables and hard-wired appliances, socket
outlets, circuit breakers and distribution boards. Three-phase distribution (all
supply cables and 3-phase equipment, machines and appliances).
CAT : Three-phase at theutility connection and any outdoor conductors.IV
This multimeter is rated as CAT III and is approved for measuring voltages up to
600V on single-phase products. Thismultimeter must not be used for measuring
three-phase equipment, three-phase cables or distribution boards even if
thenominal voltage is not higher than 600V.


Specyfikacje produktu

Marka: Clas Ohlson
Kategoria: multimetr
Model: UNI-T UT133B

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Clas Ohlson UNI-T UT133B, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje multimetr Clas Ohlson

Instrukcje multimetr

Najnowsze instrukcje dla multimetr

Testboy

Testboy Pen 1000 Instrukcja

2 Stycznia 2025
Testec

Testec TT-CC 220 Instrukcja

31 Grudnia 2025
Megger

Megger DPM1000 Instrukcja

28 Grudnia 2024
Rigol

Rigol RP1300H Instrukcja

28 Grudnia 2024
Extech

Extech 380942 Instrukcja

22 Grudnia 2024
Owon

Owon HDS100 Instrukcja

21 Grudnia 2024
Owon

Owon 1000A Instrukcja

18 Grudnia 2024
IWH

IWH 73556 Instrukcja

16 Grudnia 2024